Model MHX3C Humidistat Installation Manual

Limited Warranty

This humidistat is warranted to the consumer against defects in materials and workmanship for a period of one year from the date 
of installation.  Defective parts will be repaired without charge except for removal, reinstallation and transportation costs.  To obtain 
repair service under this limited warranty, the consumer must send the defective part to the manufacturer.  

There are no express warranties covering this humidistat other than set forth above.  The implied warranties of merchantability and 
fitness for a particular purpose are limited in duration to one year.  The manufacturer assumes no liability in connection with the 
installation or use of this product, except as stated in this limited warranty.  The manufacturer will in no event be liable for incidental 
or consequential damages.

Any questions pertaining to this limited warranty should be addressed to the manufacturer.  USA: The manufacturer has elected not 
to make available the informal dispute settlement mechanism which is specified in the Magnuson-Moss Warranty Act.

Troubleshooting

Humidifier turns on and off repeatedly:

1.  If mounted on wall, verify wire clearance hole in wall is sufficiently insulated to prevent drafts from affecting the humidistat.
2.  If mounted on return air duct, verify humidistat is at least 24” upstream of humidifiers air discharge.

Humidifier operates continuously:

1.  When the humidity in the home is less than the knob setting on the humidistat the stat will operate the humidifier until the 

humidity is higher. Reduce knob setting.

2.  Verify function of solenoid valve.

No humidifier operation in “ON” mode:

1.  Set the thermostat to operate both furnace burner and blower. Operation may be necessary for system power.
2.  Verify terminals  "NO" and "C" are used on the humidistat. These are the contacts for humidification.
3.  Check voltage at terminals  "NO" and "C". There should be no voltage for an Elite Steam or 1137/1000 power humidifier. 

Voltage should be 20-30 VAC from most others.

4.  Verify humidifier operation by bypassing the humidistat.

Ideal humidity is not achieved:

1.  Excess air infiltration. Seal sources of air loss.
2.  Technical fault with humidifier. Check water supply, electrical connections and condition of the evaporator pad. Verify metering 

orifice at the solenoid valve is not obstructed.

3.  Humidifier run time is too short. Switch water supply to hot water if appropriate (use copper tubing).
4.  Humidifier is undersized. Switch water supply to hot water if appropriate (use copper tubing). Add additional unit(s) or replace 

existing unit with a larger unit.

Using the MHX3C

USA:       www.GeneralFilters.com

USA:       Toll Free  (866) 476-5101

If you do not have on-line access, please mail a postcard with your name, phone number, email address, product 

purchased, model number, date of purchase, serial number, and contractor contact information to:
 

USA:        

General Filters, Inc.  43800 Grand River Ave  Novi, MI  48375 

 

Canada:   

400 Midwest Road Toronto, ON, M1P 3A9 Canada

Canada:  www.CGFProducts.com

Canada:  Toll Free  (888) 216-9184

WARNING:  Turn off power before performing maintenance.

CAUTION:  Maintenance should be performed only by a qualified contractor.

!

!

To adjust humidity using your MHX3C, simply turn the dial to the left or right.  Turning to the left, 
towards the number 75, increases humidity output.  Turning the dial to the right, or the number 10, 
decreases the humidity output.  

After each adjustment, wait 2-3 days before adjusting again.  This is how long it can take for new 
humidity levels to reach all areas of your home.

Ideal humidity is between 40 and 60%.  See additional recommended settings to the right.

At Outside 

Temperature

Recommended 

Setting

-20°F

-29°C

15%

-10°F

-23°C

20%

0°F

-18°F

25%

+10°F -12°C

30%

+20°F

-7°C

35%

+30°F

-1°C

40%

FORM NO. MHX3C _REV B 

(8-2018; JPF; InDesign) 

Summary of Contents for MHX3C

Page 1: ...URN OFF POWER TO THE HVAC SYSTEM prior to installing or servicing the humidifier or humidistat Improper operation can result in over or under humidification Improper voltage can cause malfunction or damage to the control All local building and electrical codes must be followed The technical specifications for this product and the contents of the user manual are subject to change without notice WAR...

Page 2: ...Attach directly to the wall using the two screws provided in the slotted holes 5 Connect wires to screw terminals on the control assembly as shown in DIAGRAMS 1 5 Replace the face DUCT MOUNTING ON THE RETURN AIR WALL BASE Humidistat Dehumidistat versions optional Do not install the humidistat on the warm air duct or within 48 of UV light 1 Locate the humidistat at least 24 upstream of the humidifi...

Page 3: ...distat L1 N G Humidifier Control Leads Yellow Wires Humidifier Power Cord Humidifier 24V Aux Power Red Wires 120V Switched With Furnace Heating Cycle DIAGRAM 5 Wiring 120V 1137 1000 Power Humidifiers With Constant 120V Supply Humidifier Control Leads Yellow Wires Humidifier Power Cord Humidifier 24V Aux Power Red Wires L1 N G 727 58 24V Transformer Omit if Power Supply is 20 30 VAC 120V Switched W...

Page 4: ...and C are used on the humidistat These are the contacts for humidification 3 Check voltage at terminals NO and C There should be no voltage for an Elite Steam or 1137 1000 power humidifier Voltage should be 20 30 VAC from most others 4 Verify humidifier operation by bypassing the humidistat Ideal humidity is not achieved 1 Excess air infiltration Seal sources of air loss 2 Technical fault with hum...