7

 

 

6  MACHINE SPECIFICATIONS 

          

            FIGURE 3 

 

FRAME STRUCTURE 

Unitized, welded steel plate. 

DRIVE SYSTEM 

Random orbit, direct shaft mount. 

NUMBER 

ELASTOMERIC 

RUBBER MOUNTS 

 

 

NUMBER BLADE 

OSCILLATIONS 

 

3400 per minute 

MAIN FRAME WIDTH 

8-1/4 inches (210 mm) 

MAIN FRAME LENGTH 

23-1/4 inches (591 mm) 

OPERATOR HANDLE 

WIDTH 

23-3/64 inches (585.4 mm) 

OPERATING LENGTH 

36-13/32 inches (924.8 mm)

 

OPERATING HEIGHT 

43-1/2 inches (1105 mm)  

WEIGHT 

44 lbs (19.6 Kg), less blade. 

ELECTRIC MOTOR 

2300W, 115 VAC, 60 HZ, 15 Amperes 

thermally protected. 

EXTENSION CORDS 

Minimum rating for non-manufacturer supplied 

extension cords SJTW 12 AWG/3C (3 x 3.31 

mm

2

) up to a maximum cord length of 75 feet 

(22.9 M). 

OPERATING 

ENVIRONMENTS 

Non-hazardous type locations.  

REQUIRED NUMBER 

OF OPERATORS 

 

 

NOISE & VIBRATION EMISSIONS 

Description 

North America 

Europe 

Model 

FCS10GEN2 

Noise Level 

94 db 

Vibration Level 

6.2 m/s

²

 

 

RIP-R-STRIPPER POWER SOURCE 

The RIP-R-STRIPPER is designed to operate from a clean, 15 ampere, 115 

VAC, 60 Hz, nominal power source. Contact Customer Service Department for 

information for operation from 220 VAC, 50 Hz power source. Clean power 

refers to amperage available from individual electrical circuit selected.  

Additional electrical products already using same circuit will reduce available 

amperage resulting in starting/operational difficulties. Check proper voltage and 

amperage levels in addition to power source being properly grounded.  

 

 

 

Proper voltage and amperage to electric motor is essential for maximum 

productivity and service life. Low voltage and amperage will cause motor to 

overheat and can cause unrepairable damage to motor and related controls. An 

improperly grounded circuit increases risk of electric shock.  A qualified 

electrician may need to be consulted. 

IMPORTANT:

 Operating RIP-R-STRIPPER with improper voltage and/or 

amperage will result in unrepairable damage to electric motor and related 

controls. 

7  STANDARD PRODUCT & ACCESSORIES 

Refer to FIGURE 3 for overview description of standard components included 

in machine. Included in shipment for FSC10GEN2 RIP-R-STRIPPER should be 

the following: 

1 each, Model FCS10GEN2 RIP-R-STRIPPER main frame assembly 

1 each, Operator handle assembly 

1 each, T-Handle Hex Key   

1 each, 4 inch wide straight blade, part # FCS16-1100 

1 each, 10 inch wide straight blade, part # FCS16-1300 

1 each, Final inspection form  

 

ACCESSORIES 

NOTE:

 All blades are for use in general purpose projects on both wood and 

cement surfaces unless otherwise designated. 

 

Part # 

Description 

Weight 

(in lbs) 

FCS16-1050 

Blade, scoring, 4 x 6 inch 

wide, single bevel edge. 

Cement surfaces ONLY. 

0.4 

 

FCS16-1100 

Blade, straight, 4 inch x 6 

inch, single bevel edged.   

0.5 

 

FCS16-1200 

Blade, angled, 6 inch 

wide, single beveled 

edge. Cement surfaces 

ONLY. 

2.0 

 

FCS16-1300 

Blade, straight, 3 inch x 

10 inch wide, single 

beveled edge. 

0.5 

 

FCS16-1500 

Blade, scoring, 8 inch 

wide, beveled edge 

FACING UP.  For 

removing glued carpet, 

and sheet type linoleum, 

rubber, PVC, etc., from 

cement surfaces ONLY. 

0.5 

 

FCS16-1600 

Blade, scoring, 8 inch 

wide, beveled edge 

FACING DOWN.  For 

removing glued carpet, 

and sheet type linoleum, 

rubber, PVC, etc., from 

WOOD surfaces ONLY. 

0.5 

8  MACHINE SET-UP 

 

 

Open the shipping carton immediately upon receipt. Remove RIP-R-STRIPPER 

from cartons. Visually inspect contents for freight damage and/or missing parts. 

If shipping damage is evident, contact delivering carrier immediately to arrange 

for an inspection of damage by their claims representative. DO NOT DESTROY 

OR 

DISCARD SHIPPING CARTON

 UNTIL INSTRUCTED BY AUTHORIZED 

REPRESENTATIVE OF

 CARRIER 

OR FACTORY. If missing parts are 

detected, notify your dealer who will assist you in obtaining them. 

NOTE:

 If ordered with RIP-R-STRIPPER, optional blades and accessories can 

be shipped separately or included in shipping carton. 

NOTE:

 RIP-R-STRIPPER is shipped from factory with operator handle 

assembly uninstalled to main frame. All lubrication fittings are lubricated at 

factory and will not require further servicing until first scheduled maintenance.  

 

Summary of Contents for RIP-R-STRIPPER FCS10GEN2

Page 1: ...ation or when servicing product Before operation read and comprehend operator manual content Customer Service 001 507 451 5510 Customer Service Telefax 001 507 451 5511 Note There is no charge for Cus...

Page 2: ...10 covering construction CAUTION The concept of electrically powered walk behind floor covering removal equipment has been successfully utilized for many years as a practical solution to many types of...

Page 3: ...______________________ Owner Instructor __________ Date _________________________________ Operator ______________________________ Owner Instructor __________ Date _________________________________ Ope...

Page 4: ...RIP R STRIPPER operation by owner s and or operator s Program will include but is not limited to instructional operation requirements applicable OSHA requirements local laws and regulations job site...

Page 5: ...e by BACK CARE PROPER LIFTING PROCEDURES Operators will be required to lift the RIP R STRIPPER as demanded by specific job applications When lifting one person is required Utilize proper lifting techn...

Page 6: ...al RIP R STRIPPER use is on level surfaces Avoid other surface conditions which can be dangerous Special care must be exercised on slippery and or difficult uneven surfaces Watch for cracks high spots...

Page 7: ...level floors to prevent loss of control allowing machine and or operator to fall down to lower levels When moving backwards during floor covering removal process be aware of potential drop offs and ob...

Page 8: ...irable damage to electric motor and related controls 7 STANDARD PRODUCT ACCESSORIES Refer to FIGURE 3 for overview description of standard components included in machine Included in shipment for FSC10...

Page 9: ...s in OFF position and unit is not connected to power source 6 Connect power head power cord to power cord located at switch end of operator handle assembly Twist to lock to prevent separation FIGURE 6...

Page 10: ...ound cap screw shanks located toward left right sides of unit NOTE Blades are provided with a protective finish When not in use protect and store blades appropriately to prevent rust damage 7 Tighten...

Page 11: ...vel direction is important for floor removal performance and preventing damage to flooring substrates NOTE On cement surfaces blade beveled cutting edge is positioned facing up FIGURE 11 FIGURE 11 NOT...

Page 12: ...lower shear force is required to remove and increases floor covering removal rates The accepted procedure is to decrease effective blade width plus determine optimal blade angle relative to work surfa...

Page 13: ...t potential fault WARNING If operating RIP R STRIPPER in outside environment use only extension cords marked W A or W Such cords are rated for outside usage and reduce risk of electric shock DANGER DO...

Page 14: ...to determine proper material removal depths and extent of work completed Lack of proper dust collection system and or broom use can increase problem IMPORTANT Properly dispose of all accumulated floo...

Page 15: ...ps as needed IMPORTANT Electric motor is an enclosed fan cooled design Keep power head housing air vents clear of material accumulations for proper air flow cooling IMPORTANT DO NOT use thinner benzen...

Page 16: ...dry film lubricant DO NOT use other type lubricants that can attract foreign materials reducing service life 2 Exciter flywheel support bearing is sealed and will not normally require lubrication dur...

Page 17: ...for correct voltage and amperage ACCELERATED EXCITER FLYWHEEL BEARING WEAR AND OR FAILURE Possible Cause Correction Misaligned and or improperly tensioned transmission mount and exciter plate Check e...

Page 18: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 19: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 18...

Page 20: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 19...

Page 21: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 20...

Page 22: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 21...

Page 23: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 22...

Page 24: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 23...

Page 25: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 24...

Page 26: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 25...

Page 27: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 26...

Reviews: