General Equipment RIP-R-STRIPPER FCS10GEN2 Operator'S Manual Download Page 1

 
 

 
 
 

 
 

 

OPERATOR’S MANUAL 

Safety, Operation & Service Information  

 

    RIP-R-STRIPPER

®

 Floor Covering Stripper 

Model:  FCS10GEN2 
Form:   GOM03042001US, Version 1.2, Original Instructions 

 

Do not discard this manual.   

 

Keep manual readily available for reference during operation or when servicing product. 

 

Before operation, read and comprehend operator manual content. 

 

Customer Service:  

001 507 451 5510

  

 

Customer Service Telefax:  

001 507 451 5511

 

                

Note: There is no charge for Customer Service. 

 

 

Internet Address:  

http://www.generalequip.com

 

 

Email:  

[email protected]

 

 

 

Mailing Address:

   

General Equipment Company, 620 Alexander Dr. S.W., P.O. Box 334, Owatonna, MN 55060, USA 

 

 

Copyright 2021, General Equipment Company, All rights reserved.

 

 

Summary of Contents for RIP-R-STRIPPER FCS10GEN2

Page 1: ...ation or when servicing product Before operation read and comprehend operator manual content Customer Service 001 507 451 5510 Customer Service Telefax 001 507 451 5511 Note There is no charge for Cus...

Page 2: ...10 covering construction CAUTION The concept of electrically powered walk behind floor covering removal equipment has been successfully utilized for many years as a practical solution to many types of...

Page 3: ...______________________ Owner Instructor __________ Date _________________________________ Operator ______________________________ Owner Instructor __________ Date _________________________________ Ope...

Page 4: ...RIP R STRIPPER operation by owner s and or operator s Program will include but is not limited to instructional operation requirements applicable OSHA requirements local laws and regulations job site...

Page 5: ...e by BACK CARE PROPER LIFTING PROCEDURES Operators will be required to lift the RIP R STRIPPER as demanded by specific job applications When lifting one person is required Utilize proper lifting techn...

Page 6: ...al RIP R STRIPPER use is on level surfaces Avoid other surface conditions which can be dangerous Special care must be exercised on slippery and or difficult uneven surfaces Watch for cracks high spots...

Page 7: ...level floors to prevent loss of control allowing machine and or operator to fall down to lower levels When moving backwards during floor covering removal process be aware of potential drop offs and ob...

Page 8: ...irable damage to electric motor and related controls 7 STANDARD PRODUCT ACCESSORIES Refer to FIGURE 3 for overview description of standard components included in machine Included in shipment for FSC10...

Page 9: ...s in OFF position and unit is not connected to power source 6 Connect power head power cord to power cord located at switch end of operator handle assembly Twist to lock to prevent separation FIGURE 6...

Page 10: ...ound cap screw shanks located toward left right sides of unit NOTE Blades are provided with a protective finish When not in use protect and store blades appropriately to prevent rust damage 7 Tighten...

Page 11: ...vel direction is important for floor removal performance and preventing damage to flooring substrates NOTE On cement surfaces blade beveled cutting edge is positioned facing up FIGURE 11 FIGURE 11 NOT...

Page 12: ...lower shear force is required to remove and increases floor covering removal rates The accepted procedure is to decrease effective blade width plus determine optimal blade angle relative to work surfa...

Page 13: ...t potential fault WARNING If operating RIP R STRIPPER in outside environment use only extension cords marked W A or W Such cords are rated for outside usage and reduce risk of electric shock DANGER DO...

Page 14: ...to determine proper material removal depths and extent of work completed Lack of proper dust collection system and or broom use can increase problem IMPORTANT Properly dispose of all accumulated floo...

Page 15: ...ps as needed IMPORTANT Electric motor is an enclosed fan cooled design Keep power head housing air vents clear of material accumulations for proper air flow cooling IMPORTANT DO NOT use thinner benzen...

Page 16: ...dry film lubricant DO NOT use other type lubricants that can attract foreign materials reducing service life 2 Exciter flywheel support bearing is sealed and will not normally require lubrication dur...

Page 17: ...for correct voltage and amperage ACCELERATED EXCITER FLYWHEEL BEARING WEAR AND OR FAILURE Possible Cause Correction Misaligned and or improperly tensioned transmission mount and exciter plate Check e...

Page 18: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 17 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 19: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 18...

Page 20: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 19...

Page 21: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 20...

Page 22: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 21...

Page 23: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 22...

Page 24: ...FCS10GEN2 RIP R STRIPPER FLOOR COVERING STRIPPER FORM GOM03042001US VERSION 1 2 English EN 23...