![General DataComm 060A027-001 Installation & Operation Manual Download Page 104](http://html1.mh-extra.com/html/general-datacomm/060a027-001/060a027-001_installation-and-operation-manual_2210285104.webp)
AT Command Set Operation
AT Command Details
4-24
SpectraComm Dual V.34 Modem
060R122-000
Installation and Operation
Issue 15
&I
Front panel lockout
Enable
&I0
Enable
&I0
Enable
&I0
Enable
&I0
%K
Character abort
2-sec. delay
%K0
Disable
%K1
2-sec. delay
%K0
Disable
%K1
\K
Break character handling
\K5
\K5
\K5
\K5
(See the detailed description for AT command \K)
&L
Network type
Switched
network
&L0
Switched
network
&L0
Two-wire private
line
&L1
Two-wire private
line
&L1
@M
Initial Power Level Setting
-26 dBm
@M0
-26 dBm
@M0
-26 dBm
@M0
-26 dBm
@M0
@M
AES Encryption Mode
ECB
@M0
ECB
@M0
ECB
@M0
ECB
@M0
)M
Cellular Power Adjust
Disabled
)M0
Disabled
)M0
Disabled
)M0
Disabled
)M0
)M
AES Encryption Key Size
128 bits
)M0
128 bits
)M0
128 bits
)M0
128 bits
)M0
\M
Synchronous protocol
Normal
\M0
Normal
\M0
Normal
\M0
Normal
\M0
-M
MNP 10
Disabled
-M0
Disabled
-M0
Disabled
-M0
Disabled
-M0
&M
Operating mode
Async data
&M0
Sync data
&M1
Async data
&M0
Sync data
&M1
N?
Country code
Displays USA
Displays USA
Displays USA
Displays USA
\N
Asynchronous protocol
Auto-reliable
\N3
Auto-reliable
\N3
Auto-reliable
\N3
Auto-reliable
\N3
O
%
Answer mode
Ans. mode if
ringing O
%0
Ans. mode if
ringing O
%0
Ans. mode if
ringing O
%0
Ans. mode if
ringing O
%0
&P
Private line handshake mode V.34 only
&P0
V.34 only
&P0
V.34 only
&P0
V.34 only
&P0
%P
n
Store
password None
%P
n
None
%P
n
None
%P
n
None
%P
n
\P
Parity type
Auto
\P4
Auto
\P4
Auto
\P4
Auto
\P4
:P
Switched network
transmit type
Permissive
:P0
Permissive
:P0
Permissive
:P0
Permissive
:P0
P
or
T
Dialing type
Tone
T
Tone
T
Tone
T
Tone
T
Q
Response mode
Result codes
Q0
Quiet
Q1
Quiet
Q1
Quiet
Q1
\Q
Modem-to-DTE flow control
Use CTS
\Q2
Use CTS
\Q2
Use CTS
\Q2
Use CTS
\Q2
%Q
Retrain on poor signal quality Until SQ is good
%Q2
Until SQ is good
%Q2
Until SQ is good
%Q2
Until SQ is good
%Q2
%R
CPM message response
speed
Autobaud speed
%R0
Autobaud speed
%R0
Autobaud speed
%R0
Autobaud speed
%R0
&R
CTS operation
&R1
&R2
&R2
&R2
(See the detailed description for AT command &R)
\R
Asymmetrical DCE rates
Enable
\R1
Enable
\R1
Enable
\R1
Enable
\R1
*R
Remote config write access
Enable
*R0
Enable
*R0
Enable
*R0
Enable
*R0
&S
DSR operation
Real
&S1
Real
&S1
Real
&S1
Real
&S1
Table 4-1
Fixed Profile Settings (Continued)
AT Command & Description
Fixed Profile 0
Fixed Profile 1
Fixed Profile 2
Fixed Profile 3
(Sheet 2 of 4)
Summary of Contents for 060A027-001
Page 137: ......