Use and Maintenance Manual
Residential Vacuum Units
>>> Use of main vacuum unit
25
5.2
Use of the plant
Once you start the control panel can be used according to the directions back to Chapter 1.6
"Recommendations for Use."
To use the system need to connect the working tube, consisting of the sleeve, the hose and the Brava
Wireless Handle from one side and from the telescopic extension and the brushes or the various other
accessories.
In this way you can move through the different environments where the intake vents are installed to carry
out the cleaning, inserting the sleeve of the working tube in the socket suction vacuum cleaner and starting
the unit as described in Chapter 5.1.
5.3
Programming the Brava Wireless Handle
In order to give the command to start and stop must be programmed the Brava Wireless Handle with a
main vacuum unit. It’s possible to program a maximum of 5 handles.
For programming, refer to the Use and Maintenance Manual of the Brava Wireless Handle attached to the
packaging thereof.
5.4
Reset of Brava wireless handle
If you exceed the maximum number of 5 handles programmed and it becomes necessary to
replace one of these, it is necessary to reset the memory and do a new programming
To reset, refer to the Manual of Use and Maintenance of the handle in attached to the packaging
of this.
5.5
Self-cleaning function
Total models have a self-cleaning system with filter that can operate at intervals programmable according
to requirements. Maintenance is therefore limited to the replacement of the collection bag.
In the USER MENU of the interface there is this submenu:
GDA
SELF-CLEANING
only if the self-cleaning function has been activated on the machine. This submenu indicates the motor
operation time after which the filter is automatically cleaned.
This function overrides manual filter cleaning, meaning that it will not be necessary to clean the filter
manually, and no indication for manual filter cleaning will be given.
The time of use of the system between one indication of self-cleaning and the next can be varied between
30 and 240 minutes. The preset time is 90 minutes.
TIME XXX MINUTES
SELF-CLEANING
Operation of the device is triggered by a mini-compressor that feed a pressure air tank of one liter capacity
until a pressure value of 5 bar is reached. At this point an instantaneous air jet is channelled inside the filter
through a nozzle. This allows the filter to be kept clean for a longer period.