Use and Maintenance Manual
Residential Vacuum Units
>>> Residential Vacuum Units Installation
18
4.
Installation
This equipment is designed to be installed by suitably trained personnel and trained.
ATTENTION:
The entire system must be installed by qualified personnel in full compliance
with standards of workmanship and with applicable standards and regulations.
4.1.
Choice of installation position for main vacuum unit
The choice of installation position must be based on these criteria:
• The main vacuum unit must be installed indoor in well ventilated rooms, preferably in a service
room on the lowest floor of the building, like garage and technical service room. External places
are allowed, provided that the vacuum unit is always protected from inclement weather.
•
The selected position must have a clear space around the main vacuum unit and well lit so as to
make easy maintenance and repair.
• The wall mounts must allow the installation of the main vacuum unit off the ground at varying
heights depending on the model as shown to cap.4.2 that allow easy maintenance.
• The main vacuum unit must not be installed in rooms where:
- There is a source of heat in the immediate vicinity
- The temperature can reach values lower than 5 ° C and above 35 ° C
- The humidity is very high or flooding may occur
- Flammable or explosive products are stored or handled.
• The installation position must permit the fitting of air expulsion pipes no longer than 5 metres
with pipes diam. 50 mm. After this distance, pipes diam. 63 mm must be used.
Please use sensors to detect electrical traces before drilling the wall