background image

Liquid Cooled Gas Engine Generator Sets

Standby Power Rating

10KW 60 Hz
15KW 60 Hz

Power Matched

GENERAC MMC 4G15 ENGINE

Naturally Aspirated

  SOLID-STATE,  FREQUENCY  COMPENSATED  VOLTAGE 

REGULATION.  This state-of-the-art power maximizing regulation 
system is standard on all Generac models.  It provides optimized 
FAST  RESPONSE  to  changing  load  conditions  and  MAXIMUM 
MOTOR STARTING CAPABILITY by electronically torque-matching 
the surge loads to the engine.

  SINGLE SOURCE SERVICE RESPONSE from Generac's dealer 

network provides parts and service know-how for the entire unit, 
from the engine to the smallest electronic component.  You are never 
on your own when you own a GENERAC POWER SYSTEM.

  GENERAC  TRANSFER  SWITCHES,  SWITCHGEAR  AND 

ACCESSORIES.  Long  life  and  reliability  is  synonymous  with 
GENERAC POWER SYSTEMS. One reason for this confidence is 
that the GENERAC product line includes its own transfer systems, 
accessories, switchgear and controls for total system compatibility.

  INNOVATIVE  DESIGN  &  PROTOTYPE  TESTING  are  key 

components of GENERAC'S success in "IMPROVING POWER BY 
DESIGN."  But it doesn't stop there.  Total commitment to component 
testing, reliability testing, environmental testing, destruction and life 
testing, plus testing to applicable CSA, NEMA, EGSA, and other 
standards, allows you to choose GENERAC POWER SYSTEMS 
with  the  confidence  that  these  systems  will  provide  superior 
performance.

  TEST CRITERIA:

 

  PROTOTYPE TESTED

 

  SYSTEM TORSIONAL TESTED

 

  ELECTRO-MAGNETIC INTERFERENCE

 

  NEMA MG1 EVALUATION

 

  MOTOR STARTING ABILITY

 

  ShORT CIRCUIT TESTING

 

  UL 2200 COMPLIANCE AVAILABLE

FEATURES

SG010
SG015

Prime Power Rating

7.2KW 60 Hz

11KW 60 Hz

Summary of Contents for SG010

Page 1: ...HGEAR AND ACCESSORIES Long life and reliability is synonymous with GENERAC POWER SYSTEMS One reason for this confidence is that the GENERAC product line includes its own transfer systems accessories switchgear and controls for total system compatibility INNOVATIVE DESIGN PROTOTYPE TESTING are key components of GENERAC S success in IMPROVING POWER BY DESIGN Butitdoesn tstopthere Totalcommitmenttoco...

Page 2: ...ATTERY CHARGE ALTERNATOR 15 Amps at 12 V STARTER MOTOR 12 V RECOMMENDED BATTERY 1 12 V 530 CCA 26F GROUND POLARITY Negative APPLICATION ENGINEERING DATA GENERATOR FEATURES Rating definitions Standby Applicable for supplying emergency power for the duration of the utility power outage No overload capability is available for this rating All ratings in accordance with BS5514 ISO3046 and DIN6271 Prime...

Page 3: ...6 1 75 Coolant flow min 60 Hz lit US gal 25 6 6 25 6 6 25 6 6 25 6 6 Heat rejection to coolant 60 Hz BTU hr 48 000 72 000 35 000 53 000 Cooling air flow 60 Hz m3 min cfm 40 883 40 883 40 883 40 883 COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz m3 min cfm 0 8 29 1 2 41 0 6 22 0 9 32 EXHAUST Exhaust flow at rated output 60 Hz m3 min cfm 2 7 96 3 9 137 2 1 75 3 0 32 Max recommended back press...

Page 4: ... Solenoid Low Coolant Temperature Secondary Fuel Regulator N G and L P Low Fuel Pressure Alarm Stainless Steel Flexible Exhaust Connection Battery Charge Alternator Battery Cables Battery Tray Vibration Isolation of Unit to Mounting Base 12 Volt Solenoid Activated Starter Motor Air Cleaner Fan Guard Control Console Radiator Duct Adapter OPTIONAL FUEL ACCESSORIES Flexible Fuel Lines L P Liquid With...