Section 5: Mounting and Connecting
,QVWDOODWLRQ*XLGHOLQHV
(000670)
WARNING
Hot Surfaces. Locate and install the Generac PV Link
so as to avoid inadvertant contact. When operating in hot
weather the optimizer will become hot and could result in
personal injury.
•
,QVWDOO39/LQNVFORVHWRWKHHGJHRIWKHDUUD\IRU
EHVWFRROLQJDQGHDVLHUVHUYLFHDFFHVV
•
&DOFXODWH PD[LPXP VXEVWULQJ OHQJWK XVLQJ WKH
Installation Design
ZRUNVKHHWLQ6HFWLRQRIWKLV
PDQXDO
•
7KH PRGXOHV ZLWKLQ HDFK VXEVWULQJ PXVW EH WKH
VDPHW\SHDQGDOOVKRXOGEHPRXQWHGDWWKHVDPH
SLWFKDQGRULHQWDWLRQ
•
:KHQLQVWDOOLQJDV\VWHPZLWKPXOWLSOH39/LQNVLW
LVQRWQHFHVVDU\WRPDWFKWKHQXPEHURIPRGXOHV
URRISLWFKRURULHQWDWLRQDFURVVDOOVXEVWULQJVLQDQ
DUUD\
•
(QVXUH DW OHDVW D LQ PP FOHDUDQFH
EHWZHHQWKHKHDWVLQNILQVDQGDGMDFHQWVXUIDFHVWR
DOORZVXIILFLHQWDLUIORZIRUFRROLQJ
•
7KH 39 /LQN FDQ EH LQVWDOOHG LQ DQ\ RULHQWDWLRQ
&RROLQJ LV PRVW HIIHFWLYH LI ILQV DUH RULHQWHG YHUWL
FDOO\
•
0RXQW WKH RSWLPL]HU DW OHDVW IW P IURP WKH
JURXQG
•
(QVXUH WKH 3956( HQFORVXUH LV D PLQLPXP ò LQ
PPIURPWKH39PRGXOHVXEVWUDWH
•
5HYLHZWKH39PRGXOHLQVWUXFWLRQVWRGHWHUPLQHLI
DQ\ UHVWULFWLRQV IRU PRXQWLQJ GHYLFHV XQGHU WKH
PRGXOHH[LVWDVSDUWRIWKH39PRGXOHOLVWLQJ
$WWDFKPHQWDQG*URXQGLQJ
(000657)
Equipment damage. Never leave the PV Link MC4 connectors
open and exposed to the atmosphere overnight or during
rain. Unwired connectors should remain plugged together as
originally packaged. Failure to do so could cause equipment
damage.
CAUTION
127(
3URSHU JURXQGLQJ LV QHFHVVDU\ IRU 5(EXV FRP
PXQLFDWLRQ
,QVWDOOLQJWR0HWDOOLFRU*URXQGHG6WUXFWXUHV
6HH
Figure 5-1
,QVWDOOWKH39/LQNZLWKODEHO$IDFLQJ
XS$WWDFKPHQWIODQJHVORWV%DFFHSWIDVWHQHUVXSWR0
RU´LQGLDPHWHU
,QVWDOOLQJWR1RQPHWDOOLFRU8QJURXQGHG
6WUXFWXUHV
•
8VHWZRIDVWHQHUVDSSURSULDWHIRUWKHVWUXFWXUH
•
6HH
Figure 5-1
)DVWHQWRJURXQGLQJWHUPLQDO&
WKH HTXLSPHQW JURXQGLQJ FRQGXFWRU XVLQJ D OXJ
VXFK DV $:* &RSSHU 6HW 6FUHZ /XJ
0F0DVWHU31.RUHTXLYDOHQW
•
8VHOLVWHGERQGLQJKDUGZDUHRQO\
•
6L]H HTXLSPHQW JURXQGLQJ FRQGXFWRU SHU 1(&
UHTXLUHPHQWVDQGWRUTXHSHUPDQXIDFWXUHUVSHFLIL
FDWLRQV
WARNING:
ELECTRIC SHOCK HAZARD - THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED. ELECTRIC SHOCK HAZARD - DC OUTPUT CONDUCTORS MAY BE ENERGIZED REGARDLESS OF SUN EXPOSURE.
CAUTION:
RISK OF ELECTRIC SHOCK - WHEN THE PHOTOVOLTAIC ARRAY IS EXPOSED TO LIGHT, IT SUPPLIES A DC VOLTAGE TO EQUIPMENT. COVER PV MODULE IN OPAQUE MATERIAL BEFORE CONNECTING OR DISCONNECTING THIS OPTIMIZER. DURING FAULT, ZERO CURRENT IS
SOURCED INTO DC ARRAY BY THIS CONVERTER. INSTALL IN ACCORDANCE WITH ALL LOCAL ORDINANCES. HOT SURFACE - TO REDUCE THE RISK OF BURNS-DO NOT TOUCH. RAPID SHUTDOWN: DEVICE AUTOMATICALLY DISCONNECTS PV ARRAY - LOSS OF GRID, MANUAL SHUTDOWN FROM
CONTROLLER, OR ANY FAULT ON REBUS™ DC NANOGRID WILL AUTOMATICALLY DISCONNECT ARRAY FROM GRID.
AVERTISSEMENT:
RISQUE DE CHOC ÉLECTRIQUE - LES CONDUCTEURS DC DE CE SYSTÈME PHOTOVOLTAÏQUE NE SONT PAS RELIÉS À LA TERRE ET POURRAIENT ÉTRE SOUS TENSION. RISQUE DE CHOC ÉLECTRIQUE - LES CONDUCTEURS À SORTIE DC POURRAIENT ÊTRE SOUS
TENSION INDÉPENDAMMENT DE LEURS EXPOSITIONS AU SOLEIL.
ATTENTION:
RISQUE DE CHOC ÉLECTRIQUE - LORSQUE LE GÉNÉRATEUR PHOTOVOLTAÏQUE EST EXPOSÉ À LA LUMIÈRE, IL FOURNIT UNE TENSION CONTINUE À L'APPAREIL. COUVREZ LE MODULE PHOTOVOLTAÏQUE D'UN MATÉRIAU OPAQUE AVANT DE BRANCHER OU DE
DÉBRANCHER CET OPTIMISEUR. EN CAS DE DÉFAUT, IL N'EXISTE AUCUN COURANT ENTRE CE CONVERTISSEUR ET LE GÉNÉRATEUR CONTINU. INSTALLEZ EN CONCORDANCE AVEC TOUS LES RÈGLEMENTS LOCAUX. SURFACE CHAUDE - AFIN DE REDUIRE LE RISQUE DE BRÛLURES, NE TOUCHEZ
PAS. SYSTÈME D'ARRÊT RAPIDE: L'APPAREIL SE DECONNECTE AUTOMATIQUEMENT DU GÉNÉRATEUR PHOTOVOLTAÏQUE - EN CAS DE PERTE DE RÉSEAU, D'ARRÊT MANUEL DE COMMANDE ÉLECTRIQUE, OU DE DEFAILLANCE DU SYSTEME "REBUS™ DC NANOGRID," LE GÉNÉRATEUR SE
MAX CONT. OUTPUT POWER
2500 W
STANDBY POWER
<1 W
RATED POWER INPUT VOLTAGE
200-360 VDC
MPPT INPUT VOLTAGE
60-360 VDC
MAX INPUT VOLTAGE
420 V
MAX OUTPUT VOLTAGE
420 V
OUTPUT
REbus™ DC Nanogrid
MAX AMBIENT TEMP
70° C
MAX OUTPUT OVERCURRENT PROTECTION
30 A
MAX INPUT CURRENT (OPERATING)
13 A @ 50ºC, 10 A @ 70ºC
MAX INPUT CURRENT (SHORT CIRCUIT)
18 A
MAX OUTPUT CURRENT (CONTINUOUS)
8 A
MAX OUTPUT CURRENT (FAULT)
10 A
ENCLOSURE
TYPE 3R
TOPOLOGY
BOOST CONVERTER
PROTECTIONS
GFCI, Photovoltaic DC Arc-Fault
Circuit-Protection, Type 1,
PV
RS
S C
on
tro
lle
d C
on
du
cto
r C
on
ne
cti
on
P
or
t
Re
fe
r t
o i
ns
tru
cti
on
s f
or
c
on
dit
io
ns
o
f u
se
RE
bu
s D
C N
an
og
rid
OUTPUT
PV
RS
S C
on
tr
ol
le
d C
on
du
ct
or
C
on
ne
ct
io
n P
or
t
Re
fe
r t
o i
ns
tr
uc
tio
ns
fo
r c
on
di
tio
ns
o
f u
se
e
PV
S
ub
st
rin
g
INPUT
Input:
Max 420V temperature corrected V
oc
.
SINGLE STRING INPUT.
Dual string input requires approval.
Output:
Connect PV Links to inverter REbus
terminals in parallel.
ENCLOSURE MUST BE GROUNDED
for REbus communication
ENCLOSURE MUST BE GROUNDED
for REbus communication
IMPORTANT INSTALLATION INSTRUCTIONS:
Made in the USA
Conforms to UL1741, UL1699B
Certified to CSA C22.2 #107.1
≤
420Voc
≤
420Voc
PV Link
/ S2502
SnapRS™ compatible substring optimizer
PV rapid shutdown system equiptment
&
%
$
Figure 5-1. Grounding Terminal Location
,QVWDOOLQJWRD*URXQGHG5DLO
•
6HH
Figure 5-1
8VHWZRUDLOFRPSDWLEOHIDVWHQHUV'
WRVHFXUHWKH39/LQNWRWKHJURXQGHGUDLO
•
8VHD:((%FOLS:LOH\31RUHTXLYD
OHQW JURXQGLQJ ZDVKHU ( EHWZHHQ WKH UDLO DQG
DWWDFKPHQWIODQJHWRSHQHWUDWHWKHUDLO¶VDQRGL]HG
FRDWLQJ
•
7RUTXHIDVWHQHUVWR1PIRU0DQG1PIRU
0RUDFFRUGLQJWRWKHFOLSPDQXIDFWXUHU¶VLQVWUXF
WLRQV
'
(
Figure 5-2. Attaching to a Grounded Metal Rail
Summary of Contents for S2502
Page 4: ...LY QVWDOODWLRQ 0DQXDO IRU 39 LQN 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 8: ...6DIHW 5XOHV HQHUDO QIRUPDWLRQ QVWDOODWLRQ 0DQXDO IRU 39 LQN 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 12: ... QVWDOODWLRQ 0DQXDO IRU 39 LQN QVWDOODWLRQ HVLJQ 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 14: ...39566 RPSOLDQFH XLGHOLQHV QVWDOODWLRQ 0DQXDO IRU 39 LQN 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 18: ... QVWDOODWLRQ 0DQXDO IRU 39 LQN 0RXQWLQJ DQG RQQHFWLQJ 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 22: ...2SHUDWLQJ QVWUXFWLRQV QVWDOODWLRQ 0DQXDO IRU 39 LQN 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 24: ... QVWDOODWLRQ 0DQXDO IRU 39 LQN 0DLQWHQDQFH 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 25: ...2ZQHU V 0DQXDO IRU 39 LQN 0DLQWHQDQFH 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 26: ... QVWDOODWLRQ 0DQXDO IRU 39 LQN 0DLQWHQDQFH 7KLV SDJH LQWHQWLRQDOO OHIW EODQN ...
Page 27: ......