Generac Power Systems RTSN100J3S Owner'S Manual Download Page 23

  

21

ITEM PART 

NO.  QTY. 

DESCRIPTION

 

0C8885 

XFER SW-W 200A600V 3P

 

0A9949 

LUG SLDLSS 400-#4 X 1/4-20 CU7AL

 

026902 

SCREW HHTT #8-32 X 1/4 CZ

 

0C7907D 

COVER LUG 3P 150/200AMP

 

024526 

SCREW HHTT 5/16-18 X 3/4 CZ

 

057329 

LUG SLDLSS 350-#6 X 13/32 AL/CU

 

027482 

WASHER SHAKEPROOF EXT 5/16 STL

 

022097 

WASHER LOCK M6-1/4

 

0C8275 

SCREW PPHM DSEMS M4-7 X 10 ZNC

 (2) 10 

0D2806 

FUSEBLOCK 30A 600V 2 POS W/SQ

  11 

090388 

SCREW HHTT M6-1.0 X 12 ZINC

  12 

0A1495 

SCREW HHTT M4-0.7 X 10 BP

 (2) 13 

063617 

RELAY PNL 12VDC DPDT 10A@240VA

  14 

047411 

SCREW HHC M6-1.0 X 16 G8.8

  15 

0A1661 

RIVET POP .156 X .675 AL

  16 

0C4449A 

ASSY NEUTRAL BL150-200A

 (3) 17 

0F59500ST14 

ENCLOSURE 3R 200AMP XFER 08GRY

 (3) 18 

0F59480ST14 

COVER 3R 200A XFER SW 08GRAY   

  19 

0G3259 

DECAL TERMINAL SHOCK HAZARD BI

 20 

0C2262 

DECAL 

TERMINAL 

STRIP

  21 

0F6165 

WASHER M6 NYLON INT HEX

  22 

PER MODEL 

DECAL DATA XFER SW

  23 

064101 

NUT HEX FL WHIZ 3/8-16

 (3) 24 

0F59510ST14 

SUBPLATE 3R 200A XFER SW 08GRY  

 25 

087680 

NUT 

WING 

M6-1.0

 26 

063378 

HOLDER 

CABLE 

TIE

  27 

064761 

TIE WRAP UL 5.6 X .10 NATL

  28 

063321 

HANDLE XFER SWITCH 1-400A

  29 

073590A 

FUSE 5A X BUSS

  30 

0D3587 

DECAL FUSE REPLACEMENT

  31 

067210A 

DECAL GROUND LUG

 32 

0A9457 

DECAL 

NEUTRAL

  33 

0D4545 

DECAL MANUAL OPERATION

 (1) 34 

0E4307 

DECAL,TEST SEQUENCE 2P TS 3R

  35 

081221 

DECAL-UL LIST HSB

  36 

0A2284 

SCREW SWAGE #8-32 X 1/2 ZYC

  37 

063306 

POWER MONITOR 3-PHASE 208Y

 (2) 38 

0F6760 

SOCKET RELAY 8P 600V-10A

  39 

067989 

NUT HEX FL WHIZ M8-1.25

  40 

022129 

WASHER LOCK M8-5/16

  41 

091472 

DUCT WIRING 1 X 1.5 (24” LG)

  42 

091472A 

COVER WIRE DUCT 1 IN (24” LG)

 43 

064126 

TRANSFRM 

240/480V-120/240V

  44 

056893 

SCREW CRIMPTITE 10-24 X 1/2

 (2) 45 

048850 

BLOCK TERM 20A 5 X 6 X 1100V

  46 

0F5985 

HARNESS 100/200A 480V RTS (NOT SHOWN)

  47 

0C4896 

SCREW FHM M8-1.25 X 20MM

(1) CENTER DECAL ON ISIDE OF THE COVER (ITEM #18)
(2) ITEMS INCLUDED WITH HARNESS
(3) REFER TO CHART BELOW FOR ENCLOSURE COLOR & MATERIAL TYPE.

Section 6 — Exploded Views and Parts List

RTS “HS” Type Transfer Switch

200A Transfer Switch Assembly (277/480V) – Drawing No. 0G2987$-E

Summary of Contents for RTSN100J3S

Page 1: ...Automatic Transfer Switch Owner s Manual ATS Service Entrance HS Type Transfer Switch This manual should remain with the unit...

Page 2: ...e isolated from the NORMAL UTILITY power source by means of an approved transfer switch Failure to properly isolate the NORMAL and STANDBY power sources from each other may result in injury or death t...

Page 3: ...while standing on metal or concrete place insulative mats over a dry wood platform Work on this equipment only while standing on such insulative mats Never work on this equipment while physically or...

Page 4: ...generator the generator then supplies the loads When UTILITY returns above a preset level the load is transferred back to the UTILITY and the generator shuts down 1 3 TRANSFER SWITCH DATA LABEL A DAT...

Page 5: ...he electrical loads that are to be connected to it Mount the switch vertically to a rigid supporting structure To prevent switch distortion level all mounting points If necessary use washers behind mo...

Page 6: ...Connect customer LOAD leads to switch termi nals T1 T2 T3 4 Connect neutral conductors of UTILITY EMERGENCY and customer LOAD to the neutral block Conductors must be properly supported of approved ins...

Page 7: ...perating the transfer switch manually or the manual handle could be damaged 3 2 1 CLOSE TO NORMAL SOURCE SIDE Before proceeding verify the position of the switch by observing window A in Figure 3 1 If...

Page 8: ...operate properly check that all three voltages are present and are of the correct voltage level DANGER FAILURE TO TURN OFF THE UTILITY SUPPLY BEFORE WORKING ON THE UTILITY CONNEC TIONS OF THE ATS WILL...

Page 9: ...frequency is correct but voltage is not the voltage regulator may require adjustment 3 4 GENERATOR TESTS UNDER LOAD 1 Set the generator s main circuit breaker to its OFF or OPEN position 2 Manually a...

Page 10: ...1 TRIPLE EKO SUITABLE FOR 1 1 25 1 50 CONDUIT 3 PLACES 179 5mm 7 1 490mm 19 3 61 5mm 2 4 41 5mm 1 6 MOUNTING HOLES 6 35mm 0 25 4 PLACES 430mm 16 9 Section 4 Installation Diagram RTS HS Type Transfer...

Page 11: ...1 TRIPLE EKO SUITABLE FOR 1 1 25 1 50 CONDUIT 3 PLACES 254mm 10 0 794mm 31 3 60 8mm 2 4 61 3mm 2 4 487mm 19 2 MOUNTING HOLES 6 35mm 0 25 4 PLACES Section 4 Installation Diagram RTS HS Type Transfer S...

Page 12: ...gram RTS HS Type Transfer Switch Drawing No 0F6405 TRIPLE EKO SUITABLE FOR 1 1 25 1 50 CONDUIT 3 PLACES 1220 9mm 48 1 332mm 13 1 1092mm 43 0 63 5mm 2 5 765 8mm 30 1 65 39mm 2 6 MOUNTING HOLES 6 35mm 0...

Page 13: ...4 S 600MCM A7822 S DISTRIBUTION PANEL 194 CUSTOMER CONNECTIONS WIRE 240 VAC 240 VAC WIRE N1 N2 N1 N2 NOTE WIRE ORIENTATION WARNING WIRE WIRE 23 23 194 057329 T CUSTOMER LOAD NEUTRAL BLOCK GROUND RTS T...

Page 14: ...TUATING COIL LS1 LS2 LS3 LIMIT SWITCHES ACTUATOR PM POWER MONITOR 3 PHASE UTILITY TR RELAY TRANSFER TS TERMINAL STRIP CUSTOMER CONNECTION 3 4 5 N2A N3 PM N1B PM F2 N2 N1 F1 N2B 126 F1 F2 FUSE 5A SENSI...

Page 15: ...H1 H4 X1 X4 H1 UTILITY 1 UTILITY 2 1 TB 2 3 4 23 194 5 Z Y NB N2B 205 E2A 126 N2B N3 N2A N1A E1A N1A N2A E2A E2 E1 N3 N3 194 E1A 23 205 N2 N1 23 194 E1 E2 N2A N1A N1A N2A N1A N2A E2A N3 N1C N1C N1C N2...

Page 16: ...UATING COIL GTS TRANSFER SWITCH CONTACTOR LS1 LS2 LS3 LIMIT SWITCHES ACTUATOR PM POWER MONITOR 3 PHASE UTILITY TR RELAY TRANSFER TS TERMINAL STRIP CUSTOMER CONNECTION 3 4 5 N1B N2A N3 PM N1B N1A PM F2...

Page 17: ...T1 T2 N1B N2A N3 E3 T3 2 1 8 7 3 4 5 6 126 205 N2A N2A N2A N1B N1B N1B N1B N1A N3 PM N3 N3 N1B N1B F2 F1 23 194 TS UTILITY 2 UTILITY 1 N2A N2A N2A N3 N3 N3 194 23 23 194 23 194 N1 N2 N2A N2A N2A N2A S...

Page 18: ...16 Section 6 Exploded Views and Parts List RTS HS Type Transfer Switch 100A Transfer Switch Assembly Drawing No 0G7277 C...

Page 19: ...TERMINAL SHOCK HAZARD 20 0C2262 1 DECAL TERMINAL STRIP 21 0F6165 2 WASHER M6 NYLON 3 22 0G5985L 1 DECAL XFRSW NON 100A 120 240 0G5968G 1 DECAL XFER SW NON 100A 120 240 23 064101 4 NUT HEX FL WHIZ 3 8...

Page 20: ...18 Section 6 Exploded Views and Parts List RTS HS Type Transfer Switch 200A Transfer Switch Assembly 120 280V Drawing No 0G2986 D...

Page 21: ...17 0A1661 2 RIVET POP 156 X 675 AL 18 0C4449A 1 ASS Y NTRL BL150 200A 19 0E2865 1 WELDMENT TRANSFER SWITCH BOX 20 0D3718 1 COVER TRANSFER SWITCH BOX 21 0G3259 2 DECAL TERMINAL SHOCK HAZARD BI 22 0C22...

Page 22: ...20 Section 6 Exploded Views and Parts List RTS HS Type Transfer Switch 200A Transfer Switch Assembly 277 480V Drawing No 0G2987 E...

Page 23: ...4 0F59510ST14 1 SUBPLATE 3R 200A XFER SW 08GRY 25 087680 1 NUT WING M6 1 0 26 063378 8 HOLDER CABLE TIE 27 064761 8 TIE WRAP UL 5 6 X 10 NATL 28 063321 1 HANDLE XFER SWITCH 1 400A 29 073590A 2 FUSE 5A...

Page 24: ...22 Section 6 Exploded Views and Parts List RTS HS Type Transfer Switch 100A Transfer Switch Assembly 120 280V Drawing No 0G2984 D...

Page 25: ...ITCH BOX 19 0C8308 2 DECAL TERMINAL SHOCK HAZARD 20 0C2262 1 DECAL TERMINAL STRIP 21 0F6165 2 WASHER M6 NYLON 22 PER MODEL 1 DECAL DATA XFER SW 23 064101 4 NUT HEX FL WHIZ 3 8 16 24 0E2866 1 SUBPLATE...

Page 26: ...24 Section 6 Exploded Views and Parts List RTS HS Type Transfer Switch 100A Transfer Switch Assembly 277 480V Drawing No 0G2985 E...

Page 27: ...DATA XFER SW 23 064101 6 NUT HEX FL WHIZ 3 8 16 24 0F59400ST14 1 SUBPLATE 24 36 ENCL RTS 08GRAY 25 087680 1 NUT WING M6 1 0 26 063378 8 HOLDER CABLE TIE 27 064761 8 TIE WRAP UL 5 6 X 10 NATL 28 063321...