6
Section 1 — General Information
Air-cooled 11 kW Generators
1.6 SPECIFICATIONS
1.6.1 GENERATOR
Model 04916-0
Rated Max. Continuous Power Capacity (Watts*)
10,000 NG/11,000 LP
Rated Voltage
120/240
Rated Max. Continuous Load Current (Amps)
120 Volts**
83.3 NG/91.7 LP
240 Volts
41.7 NG/45.8 LP
Main Line Circuit Breaker
45 Amp
Phase
1
Number of Rotor Poles
2
Rated AC Frequency
60 Hz
Power Factor
1
Recommended Air Filter
Part # C8127
Battery Requirement
Group 26/26R 12 Volts and
at -17.8° C (0° F)
525 Cold-cranking Amperes Minimum
Weight
495 Pounds
Output Sound Level @ 23 ft (7m) at full load
62.2 db (A)
Normal Operating Range
-20°F (-28.8°C) to 104°F (40°C)
* Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc. Maximum power
decreases about 3.5 percent for each 1,000 feet above sea level; and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60° F) ambient temperature.
** Load current values shown for 120 volts are maximum TOTAL values for two separate circuits. The maximum current in each circuit must not exceed the value stated for 240
volts.
1.6.2 ENGINE
Model 04916-0
Type of Engine
GT-990
Number of Cylinders
2
Rated Horsepower
30 @ 3,600 rpm
Displacement
992cc
Cylinder Block
Aluminum w/Cast Iron Sleeve
Valve Arrangement
Overhead Valves
Ignition System
Solid-state w/Magneto
Recommended Spark Plug
RC14YC
Spark Plug Gap
0.76 mm (0.030 inch)
Compression Ratio
9.5:1
Starter
12Vdc
Oil Capacity Including Filter
Approx. 1.7 Qts
Recommended Oil Filter
Part # 70185
Recommended Air Filter
Part # 0C8127
Operating RPM
2,700