Operation
10
Owner’s Manual for Generac PWRCell Inverter
4.
See
. Arrow right and press the center
button to select Confirm.
Figure 3-6. Selecting System Modes (4 of 5)
5.
Verify the mode listed at the top of
the home screen is the desired mode.
Figure 3-7. Selecting System Modes (5 of 5)
Device Pages
Each device connected to the system has its own device
page. The device page contains basic information about
the device, such as its power level and state.
•
Use the left and right arrow keys to scroll through
device pages.
•
Press the center button to launch the main menu
for that device.
NOTE:
See
. A Device Offline message
indicates the device is disconnected or has lost
communication with the inverter.
Figure 3-8. Device Offline
Enabling and Disabling Devices
NOTE:
If a device has never been enabled, it remains
disabled until enabled by a user.
After a system shutdown, each REbus device must be
enabled by the user before the device will operate. If a
device is disabled, the device will remain in a disabled
state and will not resume operation until enabled by the
user.
Once enabled, if grid power is present, the inverter will
create DC voltage establishing the REbus nanogrid. All
devices connected to REbus will wake up and begin
communications.
To enable a device:
1.
Use the right arrow key to scroll to the desired
device page.
2.
See
. Verify the device status reads
Disabled.
Figure 3-9. Enabling and Disabling Devices (1 of 3)
3.
Press the center button.
011688
009968
Photovoltaics
S2502
231.0kWh
294V
0W
device offline
Power:
PV Voltage:
E-total:
009969
(000600)
DANGER
Electrocution. Initiate a system-wide shutdown and turn the
PWRcell DC Disconnect Switch OFF on all connected
batteries before performing service. Failure to do so will
result in death, serious injury, or equipment and property
damage.
(000627a)
DANGER
Electrocution. Never enable any device during an
installation or while wires are exposed. Doing so
will result in death, serious injury, or equipment or
property damage.
009975
Summary of Contents for PWRcell APKE00014
Page 4: ...iv Owner s Manual for Generac PWRcell Inverter This page intentionally left blank ...
Page 18: ...Operation 14 Owner s Manual for Generac PWRCell Inverter This page intentionally left blank ...
Page 20: ...16 Owner s Manual for Generac PWRCell Inverter Maintenance This page intentionally left blank ...
Page 21: ...Owner s Manual for Generac PWRcell Inverter 17 Maintenance This page intentionally left blank ...
Page 22: ...18 Owner s Manual for Generac PWRCell Inverter Maintenance This page intentionally left blank ...