Maintenance
Owner’s Manual for MLT Light Tower
27
*
Perform after the initial 50 hours of operation, then on the regularly scheduled interval indicated in the schedule above.
**
Certain conditions may require the fuel tank to be drained and cleaned more often. When operating in extremely
dusty conditions, clean the fuel tank as often as necessary.
Table 4-1. Basic Maintenance Guide (Mitsubishi)
Item
Daily
50
Hours
250
Hours
400
Hours
500
Hours
1000
Hours
As
Required
Check Oil Level
Check Coolant Level
Check Fuel Level
Check Tire Pressure
Check All Electrical Connections
Inspect Radiator Fins For Debris, Clean As Required
Inspect Light Tower Winch For Proper Operation
Fuel Tank - Drain Water
Check Air Cleaner
Replace Engine Oil And Oil Filter
*
Belt And Belt Tension - Inspect And Adjust
Replace Fuel Filter
Drain And Clean Fuel Tank
**
Check Glow Plugs
Lubricate Leveling Jacks
Bolts And Nuts On The Engine - Retighten
*
Replace Heated Fuel Filter (If Equipped)
Inspect Engine Starting Battery
Air Cleaner Element - Clean, Check And Replace
Fuel System - Bleed Air
Water Sedimenter - Drain Water
Table 4-2. Basic Maintenance Guide (Kubota)
Item
Daily
50
Hours
100
Hours
200
Hours
400
Hours
500
Hours
1
Year
Check Oil Level
Check Coolant Level
Check Fuel Level
Check Tire Pressure
Check All Electrical Connections
Inspect Radiator Fins For Debris, Clean As Required
Inspect Light Tower Winch For Proper Operation
Check Fuel Pipes And Clamp Bands
Clean Air Cleaner Element
Clean Fuel Filter
Check Fan Belt Tightness
Drain Water Separator
Check Radiator Hoses And Clamp Bands
Change Engine Oil
*
Check Intake Air Line