Generac Power Systems heavy duty geenrator 1654-0 Owner'S Manual Download Page 9

9

5500 Watt Heavy  Duty Generator

DON'T OVERLOAD YOUR

GENERATOR

Capacity

You must make sure your generator can supply enough
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1.

Select the items you will power at the same time.

2.

Total the rated (running) watts of these items.This is
the amount of power your generator must produce to
keep your items running. See Figure 9.

3.

Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.

Example:

Total Rated (Running) Watts

= 3075

Highest Additional  Surge Watts

=  1800

Total Generator Output Required = 4875

Power Management

To prolong the life of your generator and attached devices,
it is important to take care when adding electrical loads to
your generator.There should be nothing connected to the
generator outlets before starting it's engine.The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1.

With nothing connected to the generator, start the
engine as described in this manual.

2.

Plug in and turn on the first load, preferably the largest
load you have.

3.

Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.

4.

Plug in and turn on the next load.

5.

Again, permit the generator to stabilize.

6.

Repeat steps 4 and 5 for each additional load.

Never add more loads than the generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.

*Wattages listed are approximate only. Check tool or
appliance for actual wattage.

Tool or Appliance

Rated (Running)

Watts

Additional Surge

(Starting) Watts

Window Air
Conditioner

1200

1800

Refrigerator

800

1600

Deep Freezer

500

500

Television

500

-

Light (75 Watts)

75

-

3075 Total

Running Watts

1800 Highest

Surge Watts

Tool or Appliance 

Rated* 

(Running) 

Watts 

Additional 

Surge 

(Starting) 

Watts 

Essentials 

 

 

Light Bulb - 75 watt 

75 

Deep Freezer 

500 

500 

Sump Pump 

800 

1200 

Refrigerator/Freezer - 18 Cu. Ft. 

800 

1600 

Water Well Pump - 1/3 HP 

1000 

2000 

Heating/Cooling 

 

 

Window AC - 10,000 BTU 

1200 

1800 

Window Fan 

300 

600 

Furnace Fan Blower - 1/2 HP 

800 

1300 

Kitchen 

 

 

Microwave Oven - 1000 Watt 

1000 

Coffee Maker 

1500 

Electric Stove - Single Element 

1500 

Hot Plate 

2500 

Family Room 

 

 

DVD/CD Player 

100 

VCR 

100 

Stereo Receiver 

450 

Color Television - 27” 

500 

Personal Computer w/17” monitor 

800 

Other 

 

 

Security System 

180 

AM/FM Clock Radio 

300 

Garage Door Opener - 1/2 HP 

480 

520 

Electric Water Heater - 40 Gallon 

4000 

DIY/Job Site 

 

 

Quartz Halogen Work Light 

1000 

Airless Sprayer - 1/3 HP 

600 

1200 

Reciprocating Saw 

960 

960 

Electric Drill - 1/2 HP 

1000 

1000 

Circular Saw - 7 1/4” 

1500 

1500 

Miter Saw - 10” 

1800 

1800 

Table Planer - 6” 

1800 

1800 

Table Saw/Radial Arm Saw - 10” 

2000 

2000 

Air Compressor - 1-1/2 HP 

2500 

2500 

Figure 9 - Wattage Reference Chart

Summary of Contents for heavy duty geenrator 1654-0

Page 1: ...amiento 7 9 25 27 Product Specifications Especificaciones Del Producto 10 28 Maintenance Mantenimiento 10 28 Storage Almacenamiento 11 29 Troubleshooting Diagnosticos De Aver as 12 30 Schematic Esquem...

Page 2: ...used without the alert symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The engine exhaust from this product con...

Page 3: ...explosion You can be blinded or severely injured Battery electrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER Do not touch hot su...

Page 4: ...ENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The generator Generator and engine owner s manuals Locking 30 Amp plug Engine oil Wheel kit IN...

Page 5: ...or on a level surface Follow the oil grade recommendations and oil fill instructions given in the engine owner s manual NOTE The generator s revolving field rides on a prelubricated and sealed ball be...

Page 6: ...cal overload Fuel Tank Capacity of seven 7 U S gallons Grounding Wing Nut Used for proper grounding of unit see page 7 Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker Switc...

Page 7: ...elps dissipate static electricity which often builds up in ungrounded devices OPERATING THE GENERATOR CAUTION Never start or stop the engine with electrical loads connected to the receptacles AND with...

Page 8: ...to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 5 500 watts of power 5 5 kW at 30 Amps for 120 Volts or 240 Volts The outlet is protected by a pu...

Page 9: ...rator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each addit...

Page 10: ...n cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator...

Page 11: ...the Generator Check that cooling air slots and openings on generator are open and unobstructed CAUTION Storage covers can be flammable Do Not place a storage cover over a hot generator Let the unit c...

Page 12: ...soline 6 Stale gasoline 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in gasoline 10 Overchoking 11 Excessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engin...

Page 13: ...13 5500 Watt Heavy Duty Generator NOTES...

Page 14: ...5500 Watt Heavy Duty Generator 14 SCHEMATIC...

Page 15: ...15 5500 Watt Heavy Duty Generator WIRING DIAGRAM...

Page 16: ...5500 Watt Heavy Duty Generator 16 EXPLODED VIEW MAIN UNIT...

Page 17: ...2 91825GS 1 ASSEMBLY Brush Holder 33 66849GS 2 TAPTITE 34 B4871GS 1 COVER Bearing Carrier 35 23762GS 2 WASHER Ext Shakeproof 36 86494GS 1 SCREW Wing Item Part Qty Description 37 B2153GS 2 SCREW Self D...

Page 18: ...GS 1 ASSEMBLY Handle 2 B187101GS 1 LEG Mounting 3 52858GS 5 NUT Locking Hex 4 39287GS 2 HHCS M8 1 25 x 45 5 93693GGS 1 AXLE 6 B4966GS 2 WHEEL 7 87005AGS 2 PIN Retaining 8 22247GS 2 WASHER Flat 9 39253...

Page 19: ...2 SPRING Hinge Pin 5 189166GS 2 PIN Hinge Cover Compact 6 68759GS 2 OUTLET 120V 20Amp Duplex 7 189165GS 4 NUT Palnut Pushnut 8 84198GS 2 CAP Circuit Breaker 9 75207GS 2 CIRCUIT BREAKER 10 43437GS 1 O...

Page 20: ...dr a resultar en el da o del equipo Siga los mensajes de seguridad para evitar o reducir los riesgos de heridas e inclusive la muerte El escape del motor de este producto contiene elementos qu micos r...

Page 21: ...a sla el generador de utilidades de energ a puede hacer que los trabajadores de electricidad sufran heridas graves e inclusive la muerte debido a la retroalimentaci n de la energ a el ctrica ADVERTEN...

Page 22: ...no etc Saque el generador de la caja de env o CONTENIDO DE LA CAJA Revise todo el contenido Si alguna de las partes no est presente o est da ada por favor llame a la linea de ayuda para generadores al...

Page 23: ...motor Coloque la generador sobre una superficie nivelada Consulte el manual del propietario del motor para a adir al motor el aceite recomendado NOTA El campo giratorio del generador se encuentra en...

Page 24: ...gachispas Tanque del Combustible El tanque tiene una capacidad de 7 galones americanos de gasolina sin contenido de plomo Terrapl n del aceite Agregue el aceite de motor aqu Tomacorriente Dobles de 12...

Page 25: ...ADOR PRECAUCI N Nunca encienda o pare el motor con las cargas el ctricas conectadas a los recept culosY con los aparatos conectados ENCENDIDOS Encienda el Motor Desconecte todas las cargas el ctricas...

Page 26: ...Este recept culo le provee poder a cargas de 120 240 Voltios AC de 60 Hz fase sencilla que requieren hasta 5 500 vatios de energ a 5 5 kW a 30 Amps para 120 Voltios o 240 Voltios La salida est proteg...

Page 27: ...aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted t...

Page 28: ...motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras para aire de enfriamiento algo del agua quedar retenida en los espacios vac os y grietas del aislamiento de...

Page 29: ...29 5500 Watt Pesado Generador NOTAS...

Page 30: ...solina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La v lvula de corte de combustible 12 La v lvula de entrada est atascada est cerrada 13 El motor ha perdido compresi n 1 Coloque del...

Page 31: ...ido autorizada o a cualquier tipo de alteraci n el mal uso negligencia accidentes sobrecarga velocidad excesiva mantenimiento inadecuado reparaci n o almacenamiento que seg n la opini n de los Product...

Page 32: ...en subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgme...

Reviews: