SPECIFICATIONS

Maximum Surge Watts  . . . . . . . . . . . . . . . . .8,500 watts
Continuous Wattage Capacity  . . . . . . . . . . .5,500 watts
Power Factor  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:

At 120 Volts  . . . . . . . . . . . . . . . . . . . . . . .45.8 Amps
At 240 Volts  . . . . . . . . . . . . . . . . . . . . . . .22.9 Amps

Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency  . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . 7 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . 175 lbs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.

Engine Maintenance

See engine owner’s manual for instructions.

If you need service for your engine, you need to determine
the engine identification number.To do so, remove the
rocker arm cover hood, item number 55 shown on
page 16, by removing the four nuts and washers holding it
in place.The engine model-type-trim number is stamped on
the side of the inner cover attached to the engine. Have
this number in hand when you call the engine service
center for assistance.

CAUTION!

Avoid prolonged or repeated skin

contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.

To Clean the Generator

CAUTION!

Never insert any object or tool

through the air cooling slots, even if the engine is
not running.

• Use a damp cloth to wipe exterior surfaces clean.
• A soft bristle brush may be used to loosen caked on dirt

or oil.

• A vacuum cleaner may be used to pick up loose dirt and

debris.

• Low pressure air (not to exceed 25 psi) may be used to

blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.

Summary of Contents for heavy duty geenrator 1654-0

Page 1: ...amiento 7 9 25 27 Product Specifications Especificaciones Del Producto 10 28 Maintenance Mantenimiento 10 28 Storage Almacenamiento 11 29 Troubleshooting Diagnosticos De Aver as 12 30 Schematic Esquem...

Page 2: ...used without the alert symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The engine exhaust from this product con...

Page 3: ...explosion You can be blinded or severely injured Battery electrolyte fluid contains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER Do not touch hot su...

Page 4: ...ENTS Check all contents If any parts are missing or damaged call the generator helpline at 1 800 270 1408 The generator Generator and engine owner s manuals Locking 30 Amp plug Engine oil Wheel kit IN...

Page 5: ...or on a level surface Follow the oil grade recommendations and oil fill instructions given in the engine owner s manual NOTE The generator s revolving field rides on a prelubricated and sealed ball be...

Page 6: ...cal overload Fuel Tank Capacity of seven 7 U S gallons Grounding Wing Nut Used for proper grounding of unit see page 7 Oil Fill Add engine oil here Recoil starter Used to start the engine Rocker Switc...

Page 7: ...elps dissipate static electricity which often builds up in ungrounded devices OPERATING THE GENERATOR CAUTION Never start or stop the engine with electrical loads connected to the receptacles AND with...

Page 8: ...to run a 120 Volt load This receptacle powers 120 240 Volt AC 60 Hz single phase loads requiring up to 5 500 watts of power 5 5 kW at 30 Amps for 120 Volts or 240 Volts The outlet is protected by a pu...

Page 9: ...rator output to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each addit...

Page 10: ...n cancer in certain laboratory animals Thoroughly wash exposed areas with soap and water KEEP OUT OF REACH OF CHILDREN DON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator...

Page 11: ...the Generator Check that cooling air slots and openings on generator are open and unobstructed CAUTION Storage covers can be flammable Do Not place a storage cover over a hot generator Let the unit c...

Page 12: ...soline 6 Stale gasoline 7 Spark plug wire not connected to spark plug 8 Bad spark plug 9 Water in gasoline 10 Overchoking 11 Excessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engin...

Page 13: ...13 5500 Watt Heavy Duty Generator NOTES...

Page 14: ...5500 Watt Heavy Duty Generator 14 SCHEMATIC...

Page 15: ...15 5500 Watt Heavy Duty Generator WIRING DIAGRAM...

Page 16: ...5500 Watt Heavy Duty Generator 16 EXPLODED VIEW MAIN UNIT...

Page 17: ...2 91825GS 1 ASSEMBLY Brush Holder 33 66849GS 2 TAPTITE 34 B4871GS 1 COVER Bearing Carrier 35 23762GS 2 WASHER Ext Shakeproof 36 86494GS 1 SCREW Wing Item Part Qty Description 37 B2153GS 2 SCREW Self D...

Page 18: ...GS 1 ASSEMBLY Handle 2 B187101GS 1 LEG Mounting 3 52858GS 5 NUT Locking Hex 4 39287GS 2 HHCS M8 1 25 x 45 5 93693GGS 1 AXLE 6 B4966GS 2 WHEEL 7 87005AGS 2 PIN Retaining 8 22247GS 2 WASHER Flat 9 39253...

Page 19: ...2 SPRING Hinge Pin 5 189166GS 2 PIN Hinge Cover Compact 6 68759GS 2 OUTLET 120V 20Amp Duplex 7 189165GS 4 NUT Palnut Pushnut 8 84198GS 2 CAP Circuit Breaker 9 75207GS 2 CIRCUIT BREAKER 10 43437GS 1 O...

Page 20: ...dr a resultar en el da o del equipo Siga los mensajes de seguridad para evitar o reducir los riesgos de heridas e inclusive la muerte El escape del motor de este producto contiene elementos qu micos r...

Page 21: ...a sla el generador de utilidades de energ a puede hacer que los trabajadores de electricidad sufran heridas graves e inclusive la muerte debido a la retroalimentaci n de la energ a el ctrica ADVERTEN...

Page 22: ...no etc Saque el generador de la caja de env o CONTENIDO DE LA CAJA Revise todo el contenido Si alguna de las partes no est presente o est da ada por favor llame a la linea de ayuda para generadores al...

Page 23: ...motor Coloque la generador sobre una superficie nivelada Consulte el manual del propietario del motor para a adir al motor el aceite recomendado NOTA El campo giratorio del generador se encuentra en...

Page 24: ...gachispas Tanque del Combustible El tanque tiene una capacidad de 7 galones americanos de gasolina sin contenido de plomo Terrapl n del aceite Agregue el aceite de motor aqu Tomacorriente Dobles de 12...

Page 25: ...ADOR PRECAUCI N Nunca encienda o pare el motor con las cargas el ctricas conectadas a los recept culosY con los aparatos conectados ENCENDIDOS Encienda el Motor Desconecte todas las cargas el ctricas...

Page 26: ...Este recept culo le provee poder a cargas de 120 240 Voltios AC de 60 Hz fase sencilla que requieren hasta 5 500 vatios de energ a 5 5 kW a 30 Amps para 120 Voltios o 240 Voltios La salida est proteg...

Page 27: ...aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted t...

Page 28: ...motor y causar problemas Adem s si el agua se introduce al generador a trav s de las ranuras para aire de enfriamiento algo del agua quedar retenida en los espacios vac os y grietas del aislamiento de...

Page 29: ...29 5500 Watt Pesado Generador NOTAS...

Page 30: ...solina 9 Sobrecebado 10 Mezcla de combustible excesivamente rica 11 La v lvula de corte de combustible 12 La v lvula de entrada est atascada est cerrada 13 El motor ha perdido compresi n 1 Coloque del...

Page 31: ...ido autorizada o a cualquier tipo de alteraci n el mal uso negligencia accidentes sobrecarga velocidad excesiva mantenimiento inadecuado reparaci n o almacenamiento que seg n la opini n de los Product...

Page 32: ...en subjected to improper or unauthorized installation or alteration misuse negligence accident overloading overspeeding improper maintenance repair or storage so as in Generac Portable Products judgme...