6
Generac
®
Power Systems, Inc.
Section 1 — General Information
Air-cooled 8.5 kW Generator
1.5 SPECIFICATIONS
1.5.1 GENERATOR
Model 004692
Rated Max. Continuous Power Capacity (Watts*)
8,500 NG/8,500 LP
Rated Voltage
120/240
Rated Max. Continuous Load Current (Amps)
120 Volts
70.8 NG/70.8 LP
240 Volts
35.4 NG/35.4 LP
Main Line Circuit Breaker
40 Amp
Phase
1
Number of Rotor Poles
2
Rated AC Frequency
60 Hz
Power Factor
1
Battery Requirement
Group 26/26R
12 Volts and
550 Cold-cranking
Amperes Minimum
Weight
470 Pounds
Output Sound Level
68 db (A)
Normal Operating Range
-20°F (28.8°C to 104°F (40°C)
* Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature,
altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet above sea
level;
and also will decrease about 1 percent for each 6° C (10° F) above 16° C (60° F) ambient temperature.
1.5.2 ENGINE
Model 004692
Type of Engine
GT-990
Number of Cylinders
2
Rated Horsepower
26 @ 3,600 rpm
Displacement
992cc
Cylinder Block
Aluminum w/Cast
Iron Sleeve
Valve Arrangement
Overhead Valves
Ignition System
Solid-state w/Magneto
Recommended Spark Plug
RC12YC
Spark Plug Gap
0.50 mm (0.020 inch)
Compression Ratio
9.5:1
Starter
12 Vdc
Oil Capacity Including Filter
Approx. 1.7 Qts
Recommended Oil Filter
Generac Part # 70185
Recommended Air Filter
Generac Part # 0C8127
Operating RPM
3,600