14
Owner’s Manual for MGG450
Operation
LP Liquid Connections (Liquid Withdrawal System)
Use
to determine the supply pipe size for LP liquid.
How to use chart:
1.
Having determined the required flow at point of use, locate this flow in the left hand column. If this falls between
two figures, use the larger of the two.
2.
Determine total length of piping required from source to point of use.
3.
Read across chart from left (required flow) to right to find the total length which is equal to, or exceeds, the
distance from source to use.
From this point, read up to find the correct size of pipe required.
Table 3-1. LP Liquid Line Sizing Chart
Liquid
Propane
Flow
Iron Pipe Size in. (cm)
0.25 (0.64)
0.375 (0.95)
0.5 (1.27)
0.75 (1.91)
1.0 (2.54)
1.25 (3.18)
1.50 (3.81)
Schedule
Schedule
Schedule
Schedule
Schedule
Schedule
Schedule
gal/hr (L/hr)
40
80
40
80
40
80
40
80
40
80
40
80
40
80
10 (38)
729 in.
1852 cm
416 in.
1057 cm
–
–
–
–
–
–
–
–
–
–
–
–
15 (57)
324 in.
823 cm
185 in.
470 cm
–
–
–
–
–
–
–
–
–
–
–
–
20 (76)
182 in.
462 cm
104 in.
264 cm
825 in.
2096 cm
521 in.
1323 cm
–
–
–
–
–
–
–
–
–
–
40 (151)
46 in.
117 cm
26 in.
66 cm
205 in.
521 cm
129 in.
328 cm
745 in.
1892 cm
504 in.
1280 cm
–
–
–
–
–
–
–
–
60 (227)
20 in.
51 cm
11 in.
28 cm
92 in.
234 cm
58 in.
147 cm
331 in.
841 cm
224 in.
569 cm
–
–
–
–
–
–
–
–
80 (303)
11 in.
28 cm
6 in.
15 cm
51 in.
130 cm
32 in.
81 cm
187 in.
475 cm
127 in.
323 cm
735 in.
1867 cm
537 in.
1364 cm
–
–
–
–
–
–
100 (379)
7 in.
18 cm
4 in
10 cm
33 in.
84 cm
21 in.
53 cm
119 in.
302 cm
81 in.
206
470 in.
1194 cm
343 in.
871 cm
–
–
–
–
–
–
120 (454)
–
–
23 in.
58 cm
15 in.
38 cm
83 in.
211 cm
56 in.
142 cm
326 in.
828 cm
238 in.
605 cm
–
–
–
–
–
–
140 (530)
–
–
15 in.
38 cm
9 in.
23 cm
61 in.
155 cm
41 in.
104 cm
240 in.
610 cm
175 in.
445 cm
813 in.
2065 cm
618 in.
1570 cm
–
–
–
–
160 (606)
–
–
13 in.
33 cm
8 in.
20 cm
47 in.
119 cm
32 in.
81 cm
184 in.
467 cm
134 in.
340 cm
623 in.
1582 cm
473 in.
1201 cm
–
–
–
–
180 (681)
–
–
–
–
37 in.
94 cm
25 in.
64 cm
145 in.
368 cm
106 in.
269 cm
491 in.
1247 cm
373 in.
947 cm
–
–
–
–
200 (757)
–
–
–
–
30 in.
76 cm
20 in.
51 cm
118 in.
300 cm
86 in.
218 cm
399 in.
1013 cm
303 in.
770 cm
–
–
–
–
240 (908)
–
–
–
–
21 in.
53 cm
14 in.
36 cm
81 in.
206 cm
59 in.
150 cm
277 in.
704 cm
211 in.
536 cm
–
–
–
–
280 (1060)
–
–
–
–
15 in.
38 cm
10 in.
25 cm
60 in.
152 cm
44 in.
112 cm
204 in.
518 cm
155 in.
394 cm
–
–
–
–
300 (1136)
–
–
–
–
13 in.
33 cm
9 in.
23 cm
52 in.
132 cm
38 in.
97 cm
177 in.
450 cm
135 in.
343 cm
785 in.
1994 cm
623 in.
1582 cm
–
–
350 (1325)
–
–
–
–
–
–
38 in.
97 cm
28 in.
71 cm
130 in.
330 cm
99 in.
251 cm
578 in.
1468 cm
459 in.
1166 cm
–
–
400 (1514)
–
–
–
–
–
–
30 in.
76 cm
22 in.
56 cm
99 in.
251 cm
75 in.
191 cm
433 in.
1100 cm
344 in.
874 cm
980 in.
2489 cm
794 in.
2017 cm
Summary of Contents for MGG450
Page 8: ...4 Owner s Manual for MGG450 Introduction and Safety This page intentionally left blank ...
Page 48: ...44 Owner s Manual for Generator Wiring Diagrams and Service Log DC Controls Page 2 of 6 ...
Page 49: ...Owner s Manual for Generator 45 Wiring Diagrams and Service Log DC Controls Page 3 of 6 ...
Page 50: ...46 Owner s Manual for Generator Wiring Diagrams and Service Log DC Controls Page 4 of 6 ...
Page 51: ...Owner s Manual for Generator 47 Wiring Diagrams and Service Log DC Controls Page 5 of 6 ...
Page 52: ...48 Owner s Manual for Generator Wiring Diagrams and Service Log DC Controls Page 6 of 6 ...
Page 53: ...Owner s Manual for Generator 49 Wiring Diagrams and Service Log Relay Connections ...
Page 54: ...50 Owner s Manual for Generator Wiring Diagrams and Service Log AC Connections ...
Page 55: ...Owner s Manual for Generator 51 Wiring Diagrams and Service Log Control Panel Layout ...
Page 56: ...52 Owner s Manual for Generator Wiring Diagrams and Service Log Control Faceplate ...
Page 57: ...Owner s Manual for Generator 53 Wiring Diagrams and Service Log CAN Wiring ...
Page 58: ...54 Owner s Manual for Generator Wiring Diagrams and Service Log Receptacle ...