![Generac Mobile G4-ECO Owner'S Manual Download Page 22](http://html.mh-extra.com/html/generac-mobile/g4-eco/g4-eco_owners-manual_2208807022.webp)
18
Owner’s Manual for G4-ECO Light Tower
General Information
Accessing the Operator Menu
NOTE:
The Operator menu is accessible only when the
unit is in Manual mode and the lamps and engine are
OFF.
Use the Operator menu to:
•
Adjust light sensor settings
•
Adjust timer settings
•
Set the system clock and language
To access the Operator menu:
1.
See
. Press and hold Lamp 1 On/Off
button (A) until the password screen appears.
2.
Enter the password by pressing controller buttons
in the following sequence:
•
Lamp 2 On/Off (B)
•
Lamp 3 On/Off (C)
•
Lamp 4 On/Off (D)
•
Start/Stop (E)
•
Manual/Auto (F)
•
Start/Stop
1
2
3
4
B
010174
C
D
F
E
A
(E)
Figure 2-6. Controller Password Screen
Navigating Within the Operator Menu
1.
Use Start/Stop button (E) and Manual/Auto button
(F) to scroll through the menu list and highlight the
desired submenu.
2.
Press Lamp 2 On/Off (B) to enter the highlighted
submenu.
3.
Use the Start/Stop button and Manual/Auto button
to highlight the desired setting.
4.
Press Lamp 2 On/Off to access the highlighted set-
ting.
5.
Use the Start/Stop button and Manual/Auto button
to adjust the setting.
6.
Press Lamp 2 On/Off to confirm the setting.
7.
Use Lamp 1 On/Off to return to the previous menu.
Setting Light Sensor
This preset automatically turns the unit ON or OFF based
on ambient lighting.
When ambient lighting drops below a user-
programmable lux threshold, a delay timer starts. The
delay timer is expressed in seconds and prevents the unit
from switching ON and OFF unintentionally. If after the
delay time has expired the ambient light remains less
than the threshold value, the unit will automatically start.
When the ambient lighting exceeds the light sensor’s lux
threshold value, the unit will shut OFF after the delay
period has expired.
To set the light sensor preset:
NOTE:
See
Navigating Within the Operator Menu
for
information on accessing and adjusting settings.
1.
Access the Operator menu.
2.
Access the Light Sensor menu.
3.
Within the Light Sensor menu, adjust the following:
•
Set Enable to Yes.
•
Set Threshold to the desired Lux value.
•
Set Delay to the desired seconds.
4.
Exit the Light Sensor and Operator menus.
5.
Set the unit to Automatic mode using the controller
Manual/Auto button.
NOTE:
When Automatic mode is selected, the default
manual mode icon
will be replaced by the light
sensor icon:
.
Summary of Contents for G4-ECO
Page 32: ...28 Owner s Manual for G4 ECO Light Tower Operation This page intentionally left blank ...
Page 39: ...Owner s Manual for G4 ECO Light Tower 35 Section 6 Wiring Diagrams AC Schematic ...
Page 40: ...36 Owner s Manual for G4 ECO Light Tower Wiring Diagrams GTL04 Controller ...
Page 41: ...Owner s Manual for G4 ECO Light Tower 37 Wiring Diagrams DC Schematic ...
Page 42: ...38 Owner s Manual for G4 ECO Light Tower Wiring Diagrams LED Light Wiring ...
Page 43: ......