background image

5

Mounting and Placing Monitors 

Mounting Options

The vibration insulating Isolation Positioner/Decoupler™ (Iso-

Pod™) table stand allows tilting of the monitor for correct 

alignment of the acoustic axis. The stand can be attached 

to three points on the enclosure, allowing vertical and two 

horizontal positions. Aim the monitor so that its acoustic axis 

point towards the listening position (see Figure 3). Vertical 

orientation is preferable, as this eliminates acoustical cancellation 

problems around the crossover frequency. Place the monitors 

symmetrically at equal distances from the listening position. If 

possible, place the listening position on the left-right centerline 

of the room (see Figure 4). When a monitor far away (1 to 2.2 

m, 3-7 ft) from the acoustically hard wall behind the monitor, an 

acoustic reflection from the wall may cause cancellation of low 

frequencies and reduce bass output. 

Acoustic reflections from objects like desks, cabinets, computer 

monitors etc. can cause unwanted colouration and blurring of 

the sound image. Minimise these by placing the monitors away 

from acoustically reflective surfaces. Putting the monitors on 

stands behind and above a mixing console usually improves the 

response over placing monitors on a meter bridge. Symmetrical 

positioning of the sound reflecting objects maintains a balanced 

soundstage (see Figure 4).

A wide variety of ceiling and wall mounts are available through 

your Genelec dealer. The 8350A can be fitted with König & 

Meyer monitor mounts using two M6 x 10 mm threaded holes 

on the enclosure back. There is an M10 x 10 mm threaded 

hole in the base of the monitor. Do not use this thread for 

mounting the monitor on a microphone stand. Monitor stands 

typically have an incompatible 3/8” UNC thread. A wide 

selection of accessories is available for Genelec monitors. 

Consult the Genelec Accessories Catalogue at www.genelec.

com or your local distributor/dealer for information.

Front Panel Light

Normally, the light on the front panel is green, indicating normal 

operational mode. Red and yellow colours are used to indicate 

special situations. See Table 2 above. 

Use with Subwoofers 

Genelec recommends using the 7300 series subwoofers. For 

more detailed system configuration and matching products, 

please consult the on-line Genelec Product Selection Tool at 

www.genelec.com.

Maintenance

There are no user serviceable parts inside the monitor.  Maintenance 

or repair must only be done by a Genelec certified service. 

Table 2. Monitor front panel light indications summary

Colour

Indication

Solid greed

Normal state, normal operation

Blinking green

GLM is adjusting the monitor

Green blink every 10 sec.

Monitor is an ISS power saving sleep 

state

Red blink

Power amplifier overload protection is 

active (audio is modified because of 

protection)

Solid red

Monitor is muted

Yellow

Monitor is not in the active (playing) 

group

Yellow blinking

Overheat protection is active (audio is 

modified because of protection)

Digital

The Digital switch selects the digital audio channels on the 

AES/EBU. Turning both switches on reproduces the sum of the 

A and B channels. A 6 dB of attenuation is applied to avoid 

overloading the monitor. If the AES/EBU cable is operated in 

dual-wire mode, the monitor detects this automatically and the 

channel selection switches have no effect.

Level

The Level switches scale down the monitor output level in 10 dB 

steps. The effects of these switches add up and combine with 

the effect of the rotary level adjustment control. The combined 

total setting range is 42 dB.

Stored

Stored switch selects the use of the controls on the monitor’s 

back panel or the settings stored inside the monitor memory 

using the GLM system calibration software. Setting the Stored 

switch to OFF position selects the settings defined by the 

monitor’s own controls. Setting the Stored switch to ON position 

selects the use of internally stored GLM settings. Using the 

Stored option overrides all adjustments done with the monitor’s  

own controls.

Operating Environment

These monitors are designed for indoor use only. The permissible 

ambient temperature is 15-35 degrees Celsius (50-95°F) and 

relative humidity 20% to 80% (non-condensing). When the 

product has been stored or transported in cool environment and 

is taken into a warm room, wait 0.5-1 hours before opening any 

packing to prevent condensation of humidity before connecting 

to mains power. Sufficient cooling must be ensured. The 

minimum clearance is 50 mm (2 in) behind, above and on both 

sides of the monitor. The space must be ventilated sufficiently 

to dissipate the heat. 

Summary of Contents for SAM 8350A

Page 1: ...8350A Operating Manual ...

Page 2: ...mple stereo to very complex 3D immersive audio setups including also one or more subwoofers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Genelec recommends setting up SAM monitoring systems using GLM You can find a detailed description of the setup a...

Page 3: ...ut off frequency Attenuation levels of 2 dB 4 dB or 6 dB both switches ON can be selected Desktop 160 Hz The desktop low frequency control switch 5 attenuates the bass frequencies around 160 Hz by 4 dB This feature is de signed to compensate for the boost often occurring at this fre quency range when the monitor is placed upon a meter bridge table or similar reflective surface Bass Tilt Control Th...

Page 4: ...SS automatic power saving function The default time for ISS activation is 60 minutes but can be adjusted in GLM Figure 3 The location of the acoustic axis is on the center line of the monitor at the given height h Figure 4 Symmetrical layout and keeping the acoustic axis clear from obstructions minimizes reflection surfaces and maintains accurate localisation because reflections are symmetrical Fi...

Page 5: ...s For more detailed system configuration and matching products please consult the on line Genelec Product Selection Tool at www genelec com Maintenance Therearenouserserviceablepartsinsidethemonitor Maintenance or repair must only be done by a Genelec certified service Table 2 Monitor front panel light indications summary Colour Indication Solid greed Normal state normal operation Blinking green G...

Page 6: ...earth contact as this may lead to personal injury To prevent fire or electric shock do not expose the unit to water or moisture Do not place any objects filled with liquid such as vases on the monitor or near it Note that the amplifier is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet Free flow of air behind the m...

Page 7: ...ted noise level in free space at 1 m on axis A weighted 5 dB Harmonic distortion at 90 dB SPL at 1 m on axis Freq 50 100 Hz 100 Hz 2 0 5 Drivers Bass Treble All drivers are magnetically shielded 205 mm 8 in cone 25 mm 1 in metal dome Weight 12 8 kg 28 2 lb Dimensions Height Width Depth Height with Iso Pod 433 mm 171 16 in 286 mm 111 4 in 278 mm 1015 16 in 452 mm 1713 16 in and on the user is encou...

Page 8: ...put power Long term output power is limited by driver protection circuitry 200 W 150 W Amplifier system THD at nominal output 0 01 System Signal to Noise ratio A weighted Bass Treble 109 dB 112 dB Mains voltage 100 240 VAC 50 60 Hz Power consumption ISS active Idle Full output short term 1 W 12 W 230 W 8350A Analog signal input connector XLR female balanced 10 kOhm Maximum analog input signal Anal...