background image

* The notch and shelving filters adjustments, AutoCal

TM

 and GLM

TM 

manual system calibration features are part of the Genelec Loudspeaker Manager (GLM

TM

) software

AMPLIFIER SECTION

SIGNAL PROCESSING SECTION

8340A

Bass amplifier short term output power

Treble amplifier short term output power

(Long term output power is limited by driver protection circuitry)

150 W 

150 W

Amplifier system THD at nominal output

<0.01%

System Signal to Noise ratio, A-weighted

Bass 

Treble

 

> 109 dB 

> 110 dB

Mains voltage

100-240 VAC 50/60 Hz

Power consumption

ISS active

Idle

Full output (short term)

< 1 W 

12 W 

180 W 

8340A

Analog signal input connector XLR female, balanced 10 kOhm

Maximum analog input signal 

Analog input sensitivity (100 dB SPL at 1 m) 

Analog input gain selection, rotary control

pin 1 gnd 

pin 2 non-inverting,  

pin 3 inverting 

+25.0 dBu 

-6 dBu 

Adjustable from +6 to -6 dBu

Digital signal input connector XLR female 110 Ohm

Digital signal output / Thru connector XLR male 110 Ohm 

 

Digital audio input

Word length 

Sample rate

Digital input sensitivity (100 dB SPL at 1 m ) 

Digital input gain sensitivity, rotary control

AES/EBU Single Wire

AES/EBU Single Wire 

 

16 - 24 bits

32 - 192 kHz 

-30 dBFS 

Adjustable from +6 to -6 dBu

Control network

Type

Connection

Proprietary GLM™ network

2 RJ45, CAT5 cables

Crossover frequency

2.6 kHz

GLM

TM

 software frequency response adjustment*

Parametric notch filters

Shelving filters

16

2 LF and 2 HF

System room response calibration

Genelec GLM AutoCal™ AutoCal

TM

, GLM

TM

 manual,  

Stand-alone*

Genelec Document D0133R003 Copyright Genelec Oy 9.2017. All data subject to change without prior notice.

www.genelec.com

International enquiries: 
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email [email protected]

In the U.S. please contact: 
Genelec, Inc., 7 Tech Circle
Natick, MA 01760, USA
Phone +1 508 652 0900
Fax +1 508 652 0909
Email [email protected]

In China please contact:
Beijing Genelec Audio Co.Ltd
B33 - 101
Universal Business Park
No. 10 Jiuxianqiao Road
Chaoyang District
Beijing, China 
Phone +86 (10) 5823 2014, 400 700 1978
Email [email protected]

In Sweden please contact:
Genelec Sverige
Ellipsvägen 10A
14175 Kungens Kurva
Phone +46 8 449 5220
Email [email protected]

Summary of Contents for SAM 8340A

Page 1: ...8340A Operating Manual ...

Page 2: ...fers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Genelec recommends setting up SAM monitoring systems using GLM You can find a detailed description of the setup and the use of GLM in the GLM System Operating Manual The setup is fast and consists of ...

Page 3: ...nd 160 Hz by 4 dB This feature is de signed to compensate for the boost often occurring at this fre quency range when the monitor is placed upon a meter bridge table or similar reflective surface Bass Tilt Control The Bass Tilt control switches swiches 3 and 4 offer three at tenuation levels for the bass response below 800 Hz usually necessary when the monitors are placed near room boundaries The ...

Page 4: ...Turning both switches on reproduces the sum of the A and B channels A 6 dB of attenuation is applied to avoid Figure 3 The location of the acoustic axis is on the center line of the monitor at the given height h Figure 4 Symmetrical layout and keeping the acoustic axis clear from obstructions minimizes reflection surfaces and maintains accurate localisation because reflections are symmetrical Figu...

Page 5: ...ubwoofers Genelec recommends using the 7300 series subwoofers For more detailed system configuration and matching products please consult the on line Genelec Product Selection Tool at www genelec com Maintenance There are no user serviceable parts inside the monitor Maintenance or repair must only be done by a Genelec certified service Table 2 Monitor front panel light indications summary Colour I...

Page 6: ...d Genelec service The monitor enclosure must not be opened Do not use this product with an unearthed mains cable or a mains connection without the protective earth contact as this may lead to personal injury To prevent fire or electric shock do not expose the unit to water or moisture Do not place any objects filled with liquid such as vases on the monitor or near it Note that the amplifier is not...

Page 7: ...l drivers are magnetically shielded 165 mm 61 2 in cone 19 mm 3 4 in metal dome Weight 8 4 kg 18 5 lb Dimensions Height Width Depth Height with Iso Pod 350 mm 1313 16 in 237 mm 93 8 in 223 mm 813 16 in 365 mm 143 8 in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If...

Page 8: ...gital input sensitivity 100 dB SPL at 1 m Digital input gain sensitivity rotary control AES EBU Single Wire AES EBU Single Wire 16 24 bits 32 192 kHz 30 dBFS Adjustable from 6 to 6 dBu Control network Type Connection Proprietary GLM network 2 RJ45 CAT5 cables Crossover frequency 2 6 kHz GLMTM software frequency response adjustment Parametric notch filters Shelving filters 16 2 LF and 2 HF System r...

Reviews: