Introduction
Congratulations and a thank you for the purchase of this
Genelec Smart Active Monitor (SAM) system. This manual
addresses the stand-alone setup and use of the 8340A SAM
monitor. These monitors can also be set up and used with the
Genelec Loudspeaker Manager GLM™ and the proprietary
Genelec monitor control network and software, offering much
more versatile acoustic settings and features. Use with the
GLM™ is described in the GLM™ System Operating Manual.
All Genelec SAM systems are designed to integrate easily
into all professional environments, supporting both standard
analog line level audio and AES/EBU formatted digital audio
signals.
The 8340A is suitable for professional monitoring tasks
demanding high precision and reliability of monitoring. The
Minimum Diffraction Enclosure™ (MDE™) and advanced
Directivity Control Waveguide™ (DCW™) technologies
provide excellent frequency balance even in difficult acoustic
environments.
Each monitor is supplied with a mains cable, one 5 m GLM
network cable and an operating manual.
Energy saving Intelligent Signal Sensing (ISS™) can be turned
on to put the monitor automatically into a deep sleep state
where the product consumes less than one Watt of power.
Upon sensing an input signal the monitor automatically wakes
up to full operation. The wait until entering the ISS power save
can be configured using the GLM software. When the ISS is
active you can have your monitoring system ready for action
at all times.
System setup using GLM™ Control
Network
Although the 8340A can be used without the GLM™ software
and control network, they only reach their full potential when
set up and calibrated using the GLM™ software. Genelec
Loudspeaker Manager GLM™ and the proprietary Genelec
monitor control network and software offer automated
acoustic equalization and alignment for any reproduction
system from simple stereo to very complex 3D immersive
audio setups including also one or more subwoofers. GLM
setup is fast and accurate. The settings can be controlled
with a computer or be permanently stored in the monitors to
make the setup available at all times even when a computer is
not in use. Genelec recommends setting up SAM monitoring
systems using GLM. You can find a detailed description of the
setup and the use of GLM™ in the GLM™ System Operating
Manual.
The setup is fast and consists of the following steps:
• Connect a CAT5 (RJ45) cable between each monitor (and
subwoofer) and finally to the control network input of the
GLM Adapter device (see Figure 1).
• Connect the GLM Adapter device to computer USB
connector.
• Using a microphone stand, place the Genelec measurement
microphone at the listening location with the microphone
pointing upwards and the microphone top at the height of the
engineer’s ear. The microphone is a part of the GLM User Kit.
• Connect the microphone cable to the microphone input in
the GLM Adapter device.
• Download the GLM software at the Genelec web site (www.
genelec.com).
• Install the GLM software and follow the instructions in the
software to measure and set up your monitors.
• If you plan to not use a computer for controlling the
monitors, use the GLM software to write the setting into the
monitors (use menu item “Store | Store the Current Group
Settings…”).
While the GLM network is disconnected the settings stored
using the Genelec Loudspeaker Manager software can be
selected in use by setting the STORED switch ON.
Setup without using the GLM
When GLM is not available, you can use the settings on the
monitor for system setup. These settings are limited but provide
the basic acoustical calibrations and input selection. To use this
method, set the STORED switch OFF.
Connect the MAINS INPUT to the mains supply. These
products support any mains voltage globally (100-240 VAC,
50-60 Hz) so they can be plugged in anywhere. If the mains
power is provided with a generator, inverter or certain lower-
quality UPS devices, we recommend filtering of the mains
power voltage harmonics and taking care that the voltage
LISTENING
POSITION
MICROPHONE
GLM
NETWORK
GLM
NETWORK
GLM
NETWORK
USB
Figure 1. GLM control network cabling
Summary of Contents for SAM 8340A