background image

one hour before opening packing to prevent 
condensation of humidity before connecting 
to mains power.  

Minimum Clearances

Do not cover the amplifier or place it in 
a closed cabinet. The space must be 
ventilated or sufficiently large to dissipate 
heat so that the ambient temperature does 
not rise above 35 degrees Celsius (95°F). 
The reflex port opening on the enclosure 
should have a clearance of at least 20 cm 
(8 in) to ensure functioning of the reflex port.

Flush Mounting

When the subwoofer is flush mounted in a 
wall or cabinet, ensure unrestricted airflow 
in the reflex port and amplifier cooling. 
Make the recess 20 cm (8 in) wider than the 
subwoofer. Place the subwoofer to the right 
side of the recess if the driver is facing the 
room. This leaves sufficient free space at 
the reflex port side. The height and depth of 
the recess should not be much bigger than 
what is needed as this may cause unwanted 
acoustic effects. 

Using Multiple Subwoofers

Multiple Genelec 7382A subwoofers can be 
coupled together in high SPL applications. 
The necessary cabling is different for digital 
and analog signals. When subwoofers 
are close to each other, the sound level 
increases typically by 6 dB for each 
doubling of the number of subwoofers. 
When subwoofers are far from each other, 
the total increase in the sound level can 
be less. It is safe to assume the increase 
is 3 dB for each doubling of the number of 
subwoofers. Accurate understanding of the 
increase in sound level requires acoustic 
measurements.  

Digital Cabling

Run a signal cable from the THRU AES/
EBU connector of the first subwoofer in the 
chain to the IN Digital connector of the next 
subwoofer.

Analog Cabling

When daisy-chaining multiple subwoofers 
with analog signals, run cables from the OUT 
1 and 2 connectors to the next subwoofer’s 
IN 1 and 2 connectors. The LFE channel has 

no output connector and can not be daisy-
chained. 

Maintenance

There are no user serviceable parts inside the 
subwoofer or the amplifier unit. Maintenance 
or repair must only be done by Genelec 
certified service personnel. 

Guarantee

Genelec guarantees the subwoofers for two 
years against manufacturing faults or defects 
altering performance. You can extend the 
guarantee to five years by registering the 
product at www.genelec.com. Refer to the 
reseller for full sales and guarantee terms.

Figure 7. Examples of subwoofer 
positioning. 1 and 2 are good starting 
positions for a single subwoofer and 
also work well with two linked subwoof-
ers. Position 3 causes a significant 
bass boost and may cause asymmetric 
spatial imaging if only one subwoofer 
is used. Position 4 also works best with 
two subwoofers. Flush mounting (pos. 
5) generally works well.

20

cm

(8

”)

f ~ 2-8 Hz

HEAVY WOODEN

OR CONCRETE

WALL

VIBRATION

ISOLATORS

HEAVY

WOODEN

OR

CONCRETE

WALL

ABSORBING

MATERIAL

VIBRATION

ISOLATORS

f ~ 2-8 Hz

ABSORBING

MATERIAL

HEAVY

WOODEN

OR

CONCRETE

WALL

VIBRATION

ISOLATORS

f ~ 2-8 Hz

Figure 3. Flush mounting the 
subwoofer in a non-absorbing wall.

Figure 4. Flush mounting the 
subwoofer in a semi-absorbing wall.

Figure 5. Incorrect flush mounting the 
subwoofer in a semi-absorbing wall.

Figure 6. Clearance needed on the reflex port side.

3

1

3

5

4

4

2

Summary of Contents for SAM 7300 Series

Page 1: ...Genelec 7382A Smart Active Subwoofer Operating Manual 7300 Series ...

Page 2: ...ckage content Each subwoofer is supplied with an individually calibrated RAM SW amplifier unit If several 7382A subwoofers are used in the same system it is very important not to mix the subwoofer amplifier pairs A mains cable a 10 m 33 3 ft Speakon signal cable one 5 m GLM network cable and this operating manual are also included Operating Environment This subwoofer is designed for indoor use onl...

Page 3: ... 50 60 Hz This enables the RAM SW amplifier to be plugged in anywhere globally When the mains power is provided with a generator inverter or certain lower quality UPS devices we recommend filtering power to remove harmonics and ensuring the voltage supply is stable Figure 1 Connector panel of the RAM SW amplifier unit Cable Gauge Max Length 4 x 2 0 mm2 14 AWG 30 m 100 ft 4 x 2 5 mm2 13 AWG 40 m 13...

Page 4: ... and subwoofer and finally to the control network input of the GLM Adapter device see Figure 1 Connect the GLM Adapter device to computer USB connector Using a microphone stand place the Genelec measurement microphone at the listening location with the microphone pointing upwards and the microphone top at the height of the engineer s ear The microphone is a part of the GLM User Kit Connect the GLM...

Page 5: ...measurements Digital Cabling Run a signal cable from the THRU AES EBU connector of the first subwoofer in the chain to the IN Digital connector of the next subwoofer Analog Cabling When daisy chaining multiple subwoofers with analog signals run cables from the OUT 1 and 2 connectors to the next subwoofer s IN 1 and 2 connectors The LFE channel has no output connector and can not be daisy chained M...

Page 6: ...ce received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and i...

Page 7: ...emale balanced 10 kOhm Maximum analog input signal Analog input sensitivity 100 dB SPL at 1 m pin 1 gnd pin 2 non inverting pin 3 inverting 24 0 dBu 6 dBu Digital signal input connector XLR female 110 Ohm Digital signal output Thru connector XLR male 110 Ohm Digital audio input Word length Sample rate Digital input sensitivity 100 dB SPL at 1 m Positive input gain selection GLM control AES EBU Sin...

Page 8: ...ontact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Room 101 1st Floor Building 71 B33 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District Beijing 100015 China Phone 86 10 5823 2014 Post code 100015 Email genelec china genelec com In Sweden please contact Genelec...

Reviews: