English 5

Table 1: Suggested tone control settings for various acoustical environments

Loudspeaker Mounting Position

Treble Tilt

Bass Tilt

Flat anechoic response

OFF

OFF

Free standing in a damped room

OFF

OFF

Free standing in a reverberant room

OFF

-2 dB

Near to a wall

OFF

-4 dB

In a corner

OFF

-6 dB

tilated or sufficiently large to dissipate heat so that 

the ambient temperature does not rise above 35 

degrees Celsius (95°F) 

Mounting options

The Genelec 4010A offers several mounting op-

tions: On the base of the loudspeaker is a 3/8” 

UNC threaded hole compatible with a standard 

microphone stand. On the rear, there are three 

pairs of threaded holes compatible with Omni-

mount

®

, VESA, and Sanus brackets. A rigid wall 

bracket provided with the 4010A allows suspend-

ing the loudspeaker on a wall in two different an-

gles. See Genelec Accessories Catalogue on 

www.genelec.com for a complete list of mount-

ing hardware options.

Maintenance

There are no user serviceable parts within the loud-

speaker. Any maintenance or repair of the 4010A 

should only be done by qualified service personnel. 

Safety considerations

Although the 4010A has been designed in accord-

ance with international safety standards, the follow-

ing warnings should be observed to ensure safe op-

eration and to maintain the loudspeaker under safe 

operating conditions:

 

• 

Servicing  and  adjustment  must  only  be  

 

performed  by  qualified  service  personnel.  

 

The loudspeaker must not be opened.

• 

Do not expose the loudspeaker to water or  

 

moisture. Do not place any objects filled with 

 

liquid, such as vases on the loudspeaker or  

 

near it. 

• 

This  loudspeaker  is  capable  of  producing  

 

sound  pressure  levels  in  excess  of  85 dB,  

 

which may cause permanent hearing damage.

• 

Free  flow  of  air  behind  the  loudspeaker  is  

 

necessary  to  maintain  sufficient  cooling.  

 

Do not obstruct airflow around the loudspeaker.

• 

Note  that  the  amplifier  is  not  completely  

 

disconnected from the AC mains service  

 

unless the mains power cord is removed  

 

from the amplifier or the mains outlet.

Guarantee

This product is guaranteed for a period of two years 

against faults in materials or workmanship. Refer to 

supplier for full sales and guarantee terms.

Compliance to FCC rules

This device complies with part 15 of the FCC Rules. Operation is subject 
to the following conditions: 
• 

This device may not cause harmful interference, and

• 

This  device  must  accept  any  interference  received,  including 

interference that may cause undesired operation. 

Note: This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful inter-
ference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communica-
tions. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the interference by 
one or more of the following measures: 
• 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that  

 

to which the receiver is connected. 

• 

Consult the dealer or an experienced radio/TV technician for help.

 
Modifications not expressly approved by the manufacturer could void 

the user’s authority to operate the equipment under FCC rules.

Summary of Contents for 4010A

Page 1: ...4010A Operating Manual ...

Page 2: ...ws on each pole Push the plug into the connector on the loudspeaker Never connect the 4010A to the loudspeaker outputs of a power amplifier integrated amplifier or receiver When all audio connections are completed connect the loudspeakers to mains with the sup plied mains cables They will switch on automati cally ISSTM Autostart The 4010A is equipped with Intelligent Signal Sens ingTM ISSTM Autost...

Page 3: ...SSER RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR NE PAS EXPOSER À L EAU OU L HUMIDITÉ AUCUN COMPOSANT À AVERTISSEMENT WARNING INSIDE REFER SERVICING TO QUALIFIED PERSONNEL TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ 292 6010W BASS TILT 4 dB BASS TILT 2 dB ISS DISABLE SENSITIVITY 10 dB TREBLE TILT 2 dB 292 4010S ON 292 4010T GND 4010A ACTIVE SPEAKER SYSTEM MAINS INPUT 50 60 Hz 30 W 100 240 V MADE IN FINLA...

Page 4: ...d near a wall or other room boundaries The attenuation levels are 2 dB switch 4 ON 4 dB switch 5 ON and 6 dB both switches ON Mounting considerations Align the loudspeakers correctly Always place the loudspeakers so that their acous tic axes see figure 1 are aimed towards the center of the listening area Only vertical placement is pre ferred as it minimises acoustical cancellation prob lems around...

Page 5: ...is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet Guarantee This product is guaranteed for a period of two years against faults in materials or workmanship Refer to supplier for full sales and guarantee terms Compliance to FCC rules This device complies with part 15 of the FCC Rules Operation is subject to the fol...

Page 6: ...ves show the effect of the Bass Tilt and Treble Tilt controls on the free field response of the 4010A 70 75 80 85 d B r A 40 20k 70 100 200 500 1k 2k 5k 10k Hz Genelec Oy 4010 dBr vs freq Hz 10 Jan 13 65 Figure 5 The upper curve group shows the horizontal directiv ity characteristics of the 4010A measured at 1 m The lower curve shows the system s power re sponse ...

Page 7: ...3 in cone 19 mm 3 4 in metal dome Weight 1 5 kg 3 3 lb Dimensions Height Width Depth 181 mm 71 8 in 121 mm 43 4 in 115 mm 41 2 in CROSSOVER SECTION Input connector 7 kOhm pin 1 pin 2 pin 3 gnd Input level for 100 dB SPL output at 1 m 6 dBu Sensitivity 10 dB off Level control range relative to max output 10 dB Sensitivity 10 dB on Desktop control operating range 0 to 4 dB 200 Hz Crossover frequency...

Page 8: ...In Sweden Genelec Sverige Ellipsvägen 10B P O Box 5521 S 141 05 Huddinge Phone 46 8 449 5220 Fax 46 8 708 7071 Email info genelec com In the USA Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China Beijing Genelec Audio Co Ltd Jianwai SOHO Building 12 Room 2605 D 1504 Chaoyang District Beijing 100022 China Phone 86 10 8580 218...

Reviews: