background image

2 English

4010A 

Active Loudspeaker

General

The bi-amplified Genelec 4010A is an extremely 

compact two way active loudspeaker designed for 

fixed installations. It contains drivers, power ampli-

fiers, active crossover filters and protection circuitry. 

The 4010A is designed for indoor use only, in tem-

peratures between 15 to 35 degrees Celsius and 

relative humidity between 20 % and 90 %. 

The MDE™ (Minimum Diffraction Enclosure™) 

loudspeaker enclosure is made of die-cast alumin-

ium and shaped to reduce edge diffraction. Com-

bined with the advanced Directivity Control Wave-

guide

TM

 (DCW

TM

),  this  design  provides  excellent 

frequency balance in difficult acoustic environments.

Delivery contents

Each 4010A is supplied with a mains cable, a 3-pin 

connector for audio signal, a keyhole type wallmount 

and an operating manual. 

Connections

Connect the mains cables only after you have com-

pleted connecting audio signal cabling. 

Audio input is via a 10 kOhm balanced connec-

tor. The pin sequence of the connector is shown 

in Figure 2.  

Connect the signal cable to the 3-pole plug pro-

vided with the loudspeaker and secure the connec-

tions by tightening the screws on each pole. Push 

the plug into the connector on the loudspeaker.

Never connect the 4010A to the loudspeaker 

outputs of a power amplifier, integrated amplifier 

or receiver.

When  all  audio  connections  are  completed, 

connect the loudspeakers to mains with the sup-

plied mains cables. They will switch on automati-

cally. 

ISS

TM

 Autostart

The 4010A is equipped with Intelligent Signal Sens-

ingTM (ISS

TM

) Autostart function, which automati-

cally turns the amplifier to Standby mode if an input 

signal has not been detected for approximately 1 

hour. The power consumption in standby mode is 

typically less than 0.5 watts. The playback will au-

tomatically resume once an input signal is detected 

from the source.

There is a slight delay in the automatic power-

ing up. If this is undesirable, the ISS

TM

 function can 

be disabled by setting the “ISS DISABLE” switch 

on the back panel to “ON” position. In this mode, 

the loudspeaker is powered on and off using the 

power switch on the back panel. 

Sensitivity control

The input sensitivity (playback level) of the 4010A 

has two alternative settings, normal and -10 dB. 

The normal setting is factory default and the low-

er, -10 dB setting can be selected by turning the 

“SENSITIVITY -10 dB” switch on the back panel to 

“ON”. 

The output levels are 100 dB @ -6dBu and 90 

dB @ -6 dBu respectively. Choose the setting that 

Operating Manual

Summary of Contents for 4010A

Page 1: ...4010A Operating Manual ...

Page 2: ...ws on each pole Push the plug into the connector on the loudspeaker Never connect the 4010A to the loudspeaker outputs of a power amplifier integrated amplifier or receiver When all audio connections are completed connect the loudspeakers to mains with the sup plied mains cables They will switch on automati cally ISSTM Autostart The 4010A is equipped with Intelligent Signal Sens ingTM ISSTM Autost...

Page 3: ...SSER RISQUE DE CHOC ÉLECTRIQUE NE PAS OUVRIR NE PAS EXPOSER À L EAU OU L HUMIDITÉ AUCUN COMPOSANT À AVERTISSEMENT WARNING INSIDE REFER SERVICING TO QUALIFIED PERSONNEL TOUTE RÉPARATION À UN PERSONNEL QUALIFIÉ 292 6010W BASS TILT 4 dB BASS TILT 2 dB ISS DISABLE SENSITIVITY 10 dB TREBLE TILT 2 dB 292 4010S ON 292 4010T GND 4010A ACTIVE SPEAKER SYSTEM MAINS INPUT 50 60 Hz 30 W 100 240 V MADE IN FINLA...

Page 4: ...d near a wall or other room boundaries The attenuation levels are 2 dB switch 4 ON 4 dB switch 5 ON and 6 dB both switches ON Mounting considerations Align the loudspeakers correctly Always place the loudspeakers so that their acous tic axes see figure 1 are aimed towards the center of the listening area Only vertical placement is pre ferred as it minimises acoustical cancellation prob lems around...

Page 5: ...is not completely disconnected from the AC mains service unless the mains power cord is removed from the amplifier or the mains outlet Guarantee This product is guaranteed for a period of two years against faults in materials or workmanship Refer to supplier for full sales and guarantee terms Compliance to FCC rules This device complies with part 15 of the FCC Rules Operation is subject to the fol...

Page 6: ...ves show the effect of the Bass Tilt and Treble Tilt controls on the free field response of the 4010A 70 75 80 85 d B r A 40 20k 70 100 200 500 1k 2k 5k 10k Hz Genelec Oy 4010 dBr vs freq Hz 10 Jan 13 65 Figure 5 The upper curve group shows the horizontal directiv ity characteristics of the 4010A measured at 1 m The lower curve shows the system s power re sponse ...

Page 7: ...3 in cone 19 mm 3 4 in metal dome Weight 1 5 kg 3 3 lb Dimensions Height Width Depth 181 mm 71 8 in 121 mm 43 4 in 115 mm 41 2 in CROSSOVER SECTION Input connector 7 kOhm pin 1 pin 2 pin 3 gnd Input level for 100 dB SPL output at 1 m 6 dBu Sensitivity 10 dB off Level control range relative to max output 10 dB Sensitivity 10 dB on Desktop control operating range 0 to 4 dB 200 Hz Crossover frequency...

Page 8: ...In Sweden Genelec Sverige Ellipsvägen 10B P O Box 5521 S 141 05 Huddinge Phone 46 8 449 5220 Fax 46 8 708 7071 Email info genelec com In the USA Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China Beijing Genelec Audio Co Ltd Jianwai SOHO Building 12 Room 2605 D 1504 Chaoyang District Beijing 100022 China Phone 86 10 8580 218...