background image

7

* The notch and shelving filters adjustments, AutoCal

TM

 and GLM

TM 

manual system calibration features are part of the Genelec Loudspeaker Manager (GLM

TM

) software

AMPLIFIER SECTION

SIGNAL PROCESSING SECTION

SySTEM SPECIFICATIONS

1238CF

Lower cut-off frequency, –3 dB

< 55 Hz

Upper cut-off frequency, –3 dB

> 20 kHz

Free field frequency response

57 Hz – 20 kHz (± 2.0 dB)

Maximum short term sine wave acoustic 
output on axis in half space, averaged from 
100 Hz to 3 kHz

@ 1 m > 117 dB SPL 

Maximum long term RMS acoustic output 
in same conditions with IEC weighted noise 
(limited by driver unit protection circuit

@ 1 m > 107 dB SPL

Maximum peak acoustic output per pair with 
music material

@ 2 m  > 124 dB

Self generated noise level in half space at 1 m 
on axis (A-weighted)

< 15 dB

Harmonic distortion at 90 dB SPL at 1 m on 
axis 

Freq: 

60…100 Hz 

 

 

> 100 Hz

< 1 %
< 0.5 %

Drivers

Bass
Midrange
Treble

2 x 210 mm (8") cone
125 mm (5”) cone 
25 mm (1") metal dome 
All drivers are magnetically 
shielded

Weight

42 kg (93 lb)

Dimensions   

Height 
Width
Depth

 
610 mm (24”)
470 mm (18

1

/

2

”)

257 mm (10

1

/

8

”)

1238CF

Bass amplifier short term output power
Midrange amplifier short term output power 
Treble amplifier short term output power

Long term output power is limited by driver unit 
protection circuitry

150 W at 4 Ohm load
120 W at 8 Ohm load 
120 W at 8 Ohm load

Slew rate

80 V/us

Amplifier system THD at nominal output

< 0.05 %

Signal to Noise ratio, referred to full output

Bass 
Midrange 
Treble

 
>100 dB 
>100 dB 
>100 dB

Mains voltage
Mains voltage operating range

100/200 or 115/230 V
-10 to +10 %

Power consumption (average)

Idle
Full output

23 VA
330 VA

1238CF

Digital signal input connector
XLR female 110 kOhm

Digital signal output / Thru connector
XLR male 110 kOhm

Analog signal input connector
XLR female, balanced 10 kOhm

AES/EBU Single Wire or 
Dual Wire

AES/EBU Single Wire or 
Dual Wire

pin 1 gnd, pin 2 +, pin 3 -

Digital audio

Word length
Sample rate

16 - 24 bits
32 - 192 kHz

Control network

Type
Connection

Proprietary GLM™ network
2 RJ45, CAT5 cables

Crossover frequency

Bass/Mid
Mid/Treble

 
420 Hz 
2.8 kHz

GLM

TM

 software frequency response adjust-

ment *

Notch filters
Shelving filters

4 LF and 2 HF
2 LF and 2 HF

System calibration

Auto Cal™, Stand-alone

Figure 5: Horizontal directivity of the 1238CF.

Figure 4: Vertical directivity of the 1238CF.

Summary of Contents for 1238CFM

Page 1: ...Genelec 1238CF DSP Loudspeaker Operating Manual 1238CF ...

Page 2: ...to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected C...

Page 3: ...ital hardware transmission of a 192 kHz sample rate is achieved using a double speed single channel cable interface This is called dual wire mode In this case one cable per channel is used and no channel selection is required Dual wire mode is automatically detected by the input stage If the digital source device has a digital level monitor pot or graphical volume fader that controls the digital l...

Page 4: ...rs in the AES EBU digital audio data Mounting Considerations Align the Loudspeakers Correctly Always place the loudspeakers so that their acoustic axes are aimed towards the listening position see Figure 2 Vertical placement is mandatory to maintain cooling behind the loud speaker Maintain Symmetry Check that the loudspeakers are placed symmetrically and at an equal distance from the listening pos...

Page 5: ...ing the effects of the adjustments however careful listening with suitable test recordings can also lead to good re sults if a test system is not available Table 1 shows some typical settings in various situations Always start adjustment by setting all switches to OFF position Measure or listen systematically through the different combina tions of settings to find the best frequency balance See Ta...

Page 6: ...ck of each loudspeaker to enable the internal Acoustic Settings and then turn it on again To set the phase control on the subwoofer connect the Center channel output of the subwoofer to the loudspeaker to be used to align phase Follow the instructions in the subwoofer user manual for setting phase and level Maintenance No user serviceable parts are to be found within the loudspeaker enclosure Any ...

Page 7: ... 1238CF Bass amplifier short term output power Midrange amplifier short term output power Treble amplifier short term output power Long term output power is limited by driver unit protection circuitry 150 W at 4 Ohm load 120 W at 8 Ohm load 120 W at 8 Ohm load Slew rate 80 V us Amplifier system THD at nominal output 0 05 Signal to Noise ratio referred to full output Bass Midrange Treble 100 dB 100...

Page 8: ...S please contact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Jianwai SOHO Tower 12 Room 2605 D 1504 Chaoyang District Beijing 100022 China Phone 86 10 8580 2180 Fax 86 10 8580 2181 Email genelec china genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O B...

Reviews: