background image

3

a small enclosure size. It is suitable for a wide variety of tasks, 
such as near field monitoring, mobile vans, broadcast and TV 
control rooms, surround sound systems and home studios. The 
advanced Directivity Control Waveguide™ (DCW™) technology 
provide excellent frequency balance even in difficult acoustic 
environments.

Amplifiers

The amplifier unit is mounted in the rear of the loudspeaker en-
closure. The unit incorporates special circuitry for driver thermal 
overload protection. Variable input sensitivity allows accurate 
level matching to console output section.

Using the Loudspeakers in Stand-Alone 
Mode

The 1238CF accepts both analogue line level input signals and 
AES/EBU formatted digital input signals. 

When the loudspeakers are not connected to a Genelec loud-
speaker control network, they operate in stand-alone mode. 
However, settings made with the Genelec Loudspeaker Manager 
software can be saved into each loudspeaker and applied even 
when the network is disconnected by setting switch 1 “STORED/
MANUAL CONTROL” on switch group 2 of each loudspeaker to 
position “STORED.” 

This manual concentrates on using the loudspeakers without the 
control network. All issues concerning use with the network are 
explained in detail in the System Operating Manual provided with 
the GLM™ Loudspeaker Manager software kit.

Connections

Each loudspeaker is supplied with a mains cable, one 5 m GLM 

network cable and an operating manual. Before connecting up, 
ensure that the mains switch is off.

“MAINS INPUT” Connector

Connect the mains supply to this connector.

“DIGITAL IN AES/EBU” Connector

Use this female XLR connector for AES/EBU formatted digital 
audio input signals. This input is selected automatically when a 
valid digital audio signal is present, and overrides the analogue 
input. 

Depending on the digital hardware, transmission of a 192 kHz 
sample rate is achieved using a double speed, single channel/
cable interface. This is called dual-wire mode. In this case one 
cable per channel is used and no channel selection is required. 
Dual-wire mode is automatically detected by the input stage.

If the digital source device has a digital level monitor pot or 
graphical volume fader that controls the digital level, it may be 
advantageous to lower the level control either on the GLM soft-
ware interface or the loudspeaker’s back panel controls rather 
than the source device, which in turn will force the use of more of 
the digital [bit] resolution in the volume control.

If the digital input is used, audio levels are referenced to 0 dBFS 
(digital Full Scale, the largest level that may be represented in 
the AES/EBU signal). Genelec DSP loudspeakers produce 100 
dB SPL at 1 meter in free space for a digital input signal of –30 
dB FS. It is advantageous to keep the digital level as high as 
possible.

“DIGITAL THRU AES/EBU” Connector

This male XLR carries an unaltered copy of the digital signal fed 
into the “DIGITAL IN AES/EBU” connector. It can be used for 
daisy-chaining up to four loudspeakers together. 

Figure 1. Connectors and 
controls on the back panel 
of the 1238CF.

2

1

ON
OFF

ON
OFF

dB

-2

-4

-8

-6

-12

0

-10

SWITCH

1

MANUAL

CTRL

-4 dB

160 Hz

ON + ON
OFF + OFF

-6 dB

-6 dB

-2 dB

STORED

DESKTOP

-2 dB -4 dB

BASS

ROLL-OFF

BASS

TILT

-2 dB -4 dB

+2 dB -4 dB

TREBLE

TILT

ON

OFF

SYSTEM LVL.

AES/EBU CH.

A

B

WF

COAX

DRIVER MUTE

SWITCH

2

-10

-20

dB

-30

SUM A AND B

MADE IN FINLAND

1238CF DSP TRI-AMPLIFIED
MONITORING SYSTEM

MAGNETICALLY SHIELDED

SERIAL NUMBER

MAINS INPUT 230 V~
50 / 60 Hz 330 W

DIGITAL IN

AES/EBU

www.genelec.com

29

2-

12

38

T-

6

ANALOG

IN

DIGITAL THRU

AES/EBU

12 V

REMOTE

STAND-ALONE USER

INTERFACE LEVEL CONTROL

STAND-ALONE USER
INTERFACE SWITCH
GROUPS 1 AND 2

GLM CONTROL

NETWORK

CONNECTORS

MAINS POWER

SWITCH

MAINS INPUT

CONNECTOR

ANALOG INPUT CONNECTOR

DIGITAL THRU CONNECTOR

DIGITAL INPUT CONNECTOR

12V REMOTE

CONNECTOR

Summary of Contents for 1238CFM

Page 1: ...Genelec 1238CF DSP Loudspeaker Operating Manual 1238CF ...

Page 2: ...to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected C...

Page 3: ...ital hardware transmission of a 192 kHz sample rate is achieved using a double speed single channel cable interface This is called dual wire mode In this case one cable per channel is used and no channel selection is required Dual wire mode is automatically detected by the input stage If the digital source device has a digital level monitor pot or graphical volume fader that controls the digital l...

Page 4: ...rs in the AES EBU digital audio data Mounting Considerations Align the Loudspeakers Correctly Always place the loudspeakers so that their acoustic axes are aimed towards the listening position see Figure 2 Vertical placement is mandatory to maintain cooling behind the loud speaker Maintain Symmetry Check that the loudspeakers are placed symmetrically and at an equal distance from the listening pos...

Page 5: ...ing the effects of the adjustments however careful listening with suitable test recordings can also lead to good re sults if a test system is not available Table 1 shows some typical settings in various situations Always start adjustment by setting all switches to OFF position Measure or listen systematically through the different combina tions of settings to find the best frequency balance See Ta...

Page 6: ...ck of each loudspeaker to enable the internal Acoustic Settings and then turn it on again To set the phase control on the subwoofer connect the Center channel output of the subwoofer to the loudspeaker to be used to align phase Follow the instructions in the subwoofer user manual for setting phase and level Maintenance No user serviceable parts are to be found within the loudspeaker enclosure Any ...

Page 7: ... 1238CF Bass amplifier short term output power Midrange amplifier short term output power Treble amplifier short term output power Long term output power is limited by driver unit protection circuitry 150 W at 4 Ohm load 120 W at 8 Ohm load 120 W at 8 Ohm load Slew rate 80 V us Amplifier system THD at nominal output 0 05 Signal to Noise ratio referred to full output Bass Midrange Treble 100 dB 100...

Page 8: ...S please contact Genelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd Jianwai SOHO Tower 12 Room 2605 D 1504 Chaoyang District Beijing 100022 China Phone 86 10 8580 2180 Fax 86 10 8580 2181 Email genelec china genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O B...

Reviews: