AMPLIFIER SECTION

SIGNAL PROCESSING SECTION

SYSTEM SPECIFICATIONS

1237A

1238A

Lower cut-off frequency, –3 dB

< 35 Hz

< 33 Hz

Upper cut-off frequency, –3 dB

> 21 kHz

> 21 kHz

Free field frequency response, 
± 2.5 dB

37 Hz – 20 kHz

35 Hz – 20 kHz

Maximum short term sine wave 
acoustic output on axis in half 
space, averaged from 100 Hz to 
3 kHz @ 1 m 

> 118 dB SPL 

> 121 dB SPL 

Maximum long term RMS acous-
tic output in the same conditions 
with IEC weighted noise (limited 
by driver protection circuit) @ 
1 m 

> 112 dB SPL

> 116 dB SPL

Maximum peak acoustic output 
per pair in a listening room with 
music material @ 2 m  

> 122 dB

> 124 dB

Self generated noise level in 
free space at 1 m on axis (A-
weighted)

< 10 dB

< 10 dB

Harmonic distortion at 95 dB 
SPL at 1 m on axis 

Freq: 

50…200 Hz 

 

> 200 Hz

< 3 %
< 0.5 %

< 1 %
< 0.5 %

Drivers

Bass
Midrange
Treble

All drivers are magnetically 
shielded

305 mm (12 in) 
cone
125 mm (5 in) 
cone 
25 mm (1 in)  
metal dome 

385 mm (15 in) 
cone
125 mm (5 in) 
cone 
25 mm (1 in)  
metal dome 

Weight  
(monitor with integrated amplifier)

42 kg (93 lb)

57 kg (126 lb)

Weight  
(monitor with amplifier removed)

36 kg (80 lb)

51 kg (113 lb)

Amplifier weight

6 kg (13 lb)

Dimensions 
(monitor enclosure)  

Height 
Width
Depth

 
 
680 mm (26

3

/

4

 in)

400 mm (15

3

/

4

 in)

380 mm (15 in)

 
 
810 mm (32 in)
480 mm (19 in)
420 mm (16

1

/

2

 in)

Amplifier dimensions
(in rack mount configuration)  

Height (front panel) 
Height (amplifier casing) 
Width (front panel)
Width (amplifier casing)
Depth

 
 

3U 132 mm (5

3

/

6

 in) 

80 mm (3

1

/

8

 in) 

483 mm (19 in) 

425 mm (16

3

/

4

 in) 

252 mm (9

15

/

16

 in)

1237A

1238A

Bass amplifier short term output 
power
Midrange amplifier short term 
output power 
Treble amplifier short term output 
power

Long term output power is limited 
by driver protection circuitry

500 W 

 

250 W 

 

200 W

Amplifier system THD at nominal 
output

< 0.01 %

Signal to Noise ratio, referred to 
full output

Bass 
Midrange 
Treble

 

>115 dB 
>115 dB 
>115 dB

Mains voltage

100-240 VAC, 50/60 Hz

Power consumption

Standby
Idle
Full output

<0.5 W 

25 W 

750 W

1237A

1238A

Analog signal input connector
XLR female, balanced 10 kOhm

Maximum analog input signal 
Analog input sensitivity  
(100 dB SPL at 1 m) 
Analog input gain selection

pin 1 gnd 

 pin 2 non-inverting,  

pin 3 inverting 

 

+25.0 dBu 

-6 dBu 

 

0, +6, +12, +18 dB

Digital signal input connector
XLR female 110 Ohm

Digital signal output / Thru  
connector XLR male 110 Ohm 
Digital audio input

Word length 
Sample rate

Digital input sensitivity  
(100 dB SPL at 1 m ) 
Digital input gain selection

AES/EBU Single Wire or Dual Wire

AES/EBU Single Wire or Dual Wire 

 

16 - 24 bits

32 - 192 kHz 

-30 dBFS 

 

0, +6, +12, +18 dB

Control network

Type
Connection

Proprietary GLM™ network

2 RJ45, CAT5 cables

Crossover frequency

Bass/Mid
Mid/Treble

 
450 Hz 
3.0 kHz

420 Hz 
3.0 kHz

GLM

TM

 software frequency 

response adjustment 

Notch filters
Shelving filters

4 LF and 2 HF
2 LF and 2 HF

System calibration

Genelec GLM AutoCal™

Summary of Contents for 1237A

Page 1: ...Genelec 1237A and 1238A Smart Active Monitors Operating Manual 1237A and 1238A ...

Page 2: ...tic reflections from objects close to monitors and the listening position can cause colouration and blurring of the sound image Symmetrical positioning of reflective objects maintains good stereo imaging When soffit flush mounting the wall surface should extend to the monitor forming a continuous surface Minimum Clearances The minimum clearance is 5 cm 2 in behind above and on both sides of the mo...

Page 3: ...H2 mm in W2 mm in 1237A 540 21 1 4 in 200 7 7 8 in 230 9 1 16 in 170 6 11 16 in 1238A 650 25 5 8 in 240 9 1 2 in 282 11 1 8 in 202 7 15 16 in both A and B subchannels are reproduced by the monitor GLM software is used to set up the monitor to specific channel assignments RAM L Amplifier Power Button The power button in the middle of the RAM L amplifier front panel controls several functions A shor...

Page 4: ...cabinet 13 Attach signal cables and the mains cable Flush Mounting the Monitor Enclosure Flush mounting offers acoustical benefits No cabinet edge diffraction will occur Low frequency reflections from the wall behind the monitor can be avoided The monitor s acoustical axis Figure 1 should point to the seated listening position The wall in which the monitors are mounted should be stiff and heavy Th...

Page 5: ...ng and adjustment must only be performed by qualified service person nel The monitor enclosure or the ampli fier enclosure must not be opened 2 Do not use this product with a mains cable with no protective earth conduc tor or a mains connection without the protective earth contact as this may lead to personal injury 3 To prevent fire or electric shock do not expose the unit to water or moisture 4 ...

Page 6: ... VIBRATION ISOLATORS f 2 8 Hz AMPLIFIER REMOVED FROM ENCLOSURE CONCRETE WALL SAND BAGS VIBRATION ISOLATORS f 2 8 Hz AMPLIFIER REMOVED FROM ENCLOSURE CONCRETE STRUCTURE MULTI LAYERED WALL WOOD CONCRETE BRICKS VIBRATION ISOLATORS f 2 8 Hz AMPLIFIER REMOVED FROM ENCLOSURE FACING PANEL FIXED TO THE WALL 50 100 mm 2 4 RUBBER GASKET 5 10 mm SPEAKER WALL Figure 14 Covering the gap between the wall and th...

Page 7: ...elevi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on 20 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 1237A dBr vs freq Hz 31...

Page 8: ... monitor with integrated amplifier 42 kg 93 lb 57 kg 126 lb Weight monitor with amplifier removed 36 kg 80 lb 51 kg 113 lb Amplifier weight 6 kg 13 lb Dimensions monitor enclosure Height Width Depth 680 mm 263 4 in 400 mm 153 4 in 380 mm 15 in 810 mm 32 in 480 mm 19 in 420 mm 161 2 in Amplifier dimensions in rack mount configuration Height front panel Height amplifier casing Width front panel Widt...

Reviews: