background image

Figure 15. The upper curve group shows the horizontal directivity 
characteristics of the 1237A in its vertical configuration measured at 
2 m. The lower curve is a 1/6 octave smoothed power response.

Figure 16. The upper curve group shows the horizontal directivity 
characteristics of the 1238A in its vertical configuration measured at 
2 m. The lower curve is a 1/6 octave smoothed power response.

vide reasonable protection against harmful 
interference in a residential installation. This 
equipment generates, uses and can radiate 
radio frequency energy and, if not installed 
and used in accordance with the instruc-
tions, may cause harmful interference to 
radio communications. However, there is no 
guarantee that interference will not occur in a 
particular installation. If this equipment does 
cause harmful interference to radio or televi-

sion reception, which can be determined by 
turning the equipment off and on, the user is 
encouraged to try to correct the interference 
by one or more of the following measures: 

1.  Reorient or relocate the receiving 

antenna. 

2.  Increase the separation between the 

equipment and receiver. 

3.  Connect the equipment into an outlet on 

20

20k

50

100

200

500

1k

2k

5k

10k

Hz

Genelec Oy 1237A                                                    (dBr) vs freq (Hz) 31 Mar 14

60°

15°

30°

45°

50

55

60

65

70

75

80

85

90

95

d

B

r

A

20

20k

50

100

200

500

1k

2k

5k

10k

Hz

Genelec Oy 1238A                                                    (dBr) vs freq (Hz) 31 Mar 14

60°

15°

30°

45°

50

55

60

65

70

75

80

85

90

95

d

B

r

A

Figure 17. 1237A horizontal directivity plot.

Figure 18. 1238A horizontal directivity plot.

a circuit different from that to which the 
receiver is connected. 

4.  Consult the dealer or an experienced 

radio/TV technician for help.

 

Modifications not expressly approved by the 
manufacturer could void the user’s authority 
to operate the equipment under FCC rules.

Figure 19. 1237A vertical directivity plot.

Figure 20. 1238A vertical directivity plot.

Summary of Contents for 1237A

Page 1: ...Genelec 1237A and 1238A Smart Active Monitors Operating Manual 1237A and 1238A ...

Page 2: ...tic reflections from objects close to monitors and the listening position can cause colouration and blurring of the sound image Symmetrical positioning of reflective objects maintains good stereo imaging When soffit flush mounting the wall surface should extend to the monitor forming a continuous surface Minimum Clearances The minimum clearance is 5 cm 2 in behind above and on both sides of the mo...

Page 3: ...H2 mm in W2 mm in 1237A 540 21 1 4 in 200 7 7 8 in 230 9 1 16 in 170 6 11 16 in 1238A 650 25 5 8 in 240 9 1 2 in 282 11 1 8 in 202 7 15 16 in both A and B subchannels are reproduced by the monitor GLM software is used to set up the monitor to specific channel assignments RAM L Amplifier Power Button The power button in the middle of the RAM L amplifier front panel controls several functions A shor...

Page 4: ...cabinet 13 Attach signal cables and the mains cable Flush Mounting the Monitor Enclosure Flush mounting offers acoustical benefits No cabinet edge diffraction will occur Low frequency reflections from the wall behind the monitor can be avoided The monitor s acoustical axis Figure 1 should point to the seated listening position The wall in which the monitors are mounted should be stiff and heavy Th...

Page 5: ...ng and adjustment must only be performed by qualified service person nel The monitor enclosure or the ampli fier enclosure must not be opened 2 Do not use this product with a mains cable with no protective earth conduc tor or a mains connection without the protective earth contact as this may lead to personal injury 3 To prevent fire or electric shock do not expose the unit to water or moisture 4 ...

Page 6: ... VIBRATION ISOLATORS f 2 8 Hz AMPLIFIER REMOVED FROM ENCLOSURE CONCRETE WALL SAND BAGS VIBRATION ISOLATORS f 2 8 Hz AMPLIFIER REMOVED FROM ENCLOSURE CONCRETE STRUCTURE MULTI LAYERED WALL WOOD CONCRETE BRICKS VIBRATION ISOLATORS f 2 8 Hz AMPLIFIER REMOVED FROM ENCLOSURE FACING PANEL FIXED TO THE WALL 50 100 mm 2 4 RUBBER GASKET 5 10 mm SPEAKER WALL Figure 14 Covering the gap between the wall and th...

Page 7: ...elevi sion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on 20 20k 50 100 200 500 1k 2k 5k 10k Hz Genelec Oy 1237A dBr vs freq Hz 31...

Page 8: ... monitor with integrated amplifier 42 kg 93 lb 57 kg 126 lb Weight monitor with amplifier removed 36 kg 80 lb 51 kg 113 lb Amplifier weight 6 kg 13 lb Dimensions monitor enclosure Height Width Depth 680 mm 263 4 in 400 mm 153 4 in 380 mm 15 in 810 mm 32 in 480 mm 19 in 420 mm 161 2 in Amplifier dimensions in rack mount configuration Height front panel Height amplifier casing Width front panel Widt...

Reviews: