Connect the MAINS INPUT to the mains supply. These 

products support any mains voltage globally (100-240 VAC, 

50-60 Hz) so they can be plugged in anywhere. If the mains 

power is provided with a generator, inverter or certain lower-

quality UPS devices, we recommend filtering of the mains 

power voltage harmonics and taking care that the voltage 

supply is stable.

The ANALOG IN connector is used for analog audio signals. The 

maximum input level is +25 dBu. The 1032C produces 100 dB 

SPL sound level at 1 meter in free space for an analogue input 

signal of -6 dBu. 

The DIGITAL IN AES/EBU female XLR connector is for AES/

EBU formatted digital audio input signals. This input is selected 

automatically when a valid digital audio signal is present. Analog 

input is selected when the AES/EBU signal input is disconnected. 

The AES/EBU input supports two channels in a single cable). 

When the digital source device controls the digital output level, it 

may be advantageous to lower the level on the monitor’s controls, 

which will enable the use of a higher digital signal level with more 

digital resolution. With digital inputs the audio is referenced to 

0 dBFS (dB relative to the digital full scale, the largest level that 

can be represented in the AES/EBU signal). The 1032C produces 

100 dB SPL sound level at 1 meter in free space for a digital 

input signal of –30 dBFS. The DIGITAL OUT male XLR carries an 

unaltered copy of the digital signal fed into the digital in connector. 

This enables daisy-chaining up to four monitors. 

Figure 2. Connectors and controls on the back panel of a 

1032C.

SMART ACTIVE MONITOR

ANALOG

IN

DIGITAL THRU

AES/EBU

DIGITAL IN

AES/EBU

GLM

NETWORK

MAINS INPUT

50 / 60 Hz 200 W

100 - 240 V~

WARNING: ELECTRIC SHOCK HAZARD. DO NOT OPEN. DO NOT SUBJECT TO
WATER OR MOISTURE. NO USER SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED PERSONNEL. USE EARTHED MAINS CONNECTION
ONLY.

AVERTISSEMENT RISQUE DE CHOC ÉLECTRIQUE. NE PAS OUVRIR. NE PAS
EXPOSER À L'EAU OU L'HUMIDITÉ. AUCUN COMPOSANT À L'INTÉRIEUR
REMPLAÇABLE PAR L'UTILISATEUR. ADRESSER TOUTE RÉPARATION À UN
PERSONNEL QUALIFIÉ. CET APPAREIL DOIT ÊTRE RACCORDÉ À LA TERRE.

LAITE ON LIITETTÄVÄ SUOJAKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN.
APPARATET MÅ TILKOPLES JORDET STIKKONTAKT.
APPARATEN SKALL ANSLUTAS TILL JORDAT UTTAG.

This device complies with FCC Part 15 and Canadian ICES-003 radio frequency
Class B emission requirements. Refer to operating manual for full information.

292-

1332

T-

6

MADE IN FINLAND

1032C

MAGNETICALLY SHIELDED

SERIAL NUMBER

www.genelec.com

RESET TO FACTORY

SETTINGS: PUSH

BUTTON FOR 10 SEC

SENSITIVITY

IN dBu FOR

100 dB SPL (1 m)

-2

+4

+2

-4

-6

+6

dBu

0

20

160

+2

-2
-4

dB

-6

0

4k

20k

BASS
TILT

800

BASS
ROLL-OFF

DESKTOP

ALL OFF

TREBLE
TILT

Frequency (Hz)

(d

B)

(d

B)

ON

OFF

B

ASS

RO

LL-O

FF

B

ASS

TI

LT

-2

-2

TR

EB

LE

TI

LT

+2

DESKTO

P1

60

Hz

-4

LE

DD

ISABL

E

A

-2

0d

B

B

ST

OR

ED

-1

0d

B

LEVE

L

DIGI

TA

L

IS

S

-4

-4

-4

CONNECTOR
PANEL

POWER
SWITCH

SENSITIVITY
ADJUSTMENT

TONE
CONTROLS

MICROPHONE

PLACED IN

THE LISTENING

POSITION

292-006

3

GLM

TERMINATOR

COMPUTER
RUNNING
GLM SOFTWARE

USB CABLE

GLM ADAPTER

GLM NETWORK
CABLE

MONITORS

SUBWOOFER

ON

ON

ON

Figure 1. GLM control network cabling

Figure 3. Connector panel detail.

Summary of Contents for 1032C

Page 1: ...1032C Smart Active Monitor Operating Manual ...

Page 2: ...ol network and software offer automated acoustic equalization and alignment for any reproduction system from simple stereo to very complex 3D immersive audio setups including also one or more subwoofers GLM setup is fast and accurate The settings can be controlled with a computer or be permanently stored in the monitors to make the setup available at all times even when a computer is not in use Ge...

Page 3: ...aisy chaining up to four monitors Figure 2 Connectors and controls on the back panel of a 1032C SMART ACTIVE MONITOR ANALOG IN DIGITAL THRU AES EBU DIGITAL IN AES EBU GLM NETWORK MAINS INPUT 50 60 Hz 200 W 100 240 V WARNING ELECTRIC SHOCK HAZARD DO NOT OPEN DO NOT SUBJECT TO WATER OR MOISTURE NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL USE EARTHED MAINS CONNECTION ONLY ...

Page 4: ...front panel LED light ISS This switch activates or deactivates the ISS automatic power saving function The default time for ISS activation is 60 minutes but can be adjusted in GLM Digital The Digital switch selects the digital audio channels on the AES EBU Turning both switches on reproduces the sum of the A and B channels A 6 dB of attenuation is applied to avoid overloading the monitor If the AE...

Page 5: ... Normal state normal operation Blinking green GLM is adjusting the monitor Green blink every 10 sec Monitor is an ISS power saving sleep state Red blink Power amplifier overload protection is active audio is modified because of protection Solid red Monitor is muted Yellow Monitor is not in the active playing group Yellow blinking Overheat protection is active audio is modified because of protectio...

Page 6: ...00 1k 2k 5k 10k Frequency Hz Genelec Oy 1032C 2 Mar 17 0 60 15 30 45 85 90 95 100 70 75 80 85 90 95 dB SPL dB SWL 20k 50 100 200 500 1k 2k 5k 10k Frequency Hz Genelec Oy 1032C 2 Mar 2017 ms 5 0 10 15 35 20 25 30 40 interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipm...

Page 7: ...PROCESSING SECTION 1032C Bass amplifier short term output power Treble amplifier short term output power Long term output power is limited by driver protection circuitry 250 W 150 W Amplifier system THD at nominal output 0 05 Mains voltage 100 240 VAC 50 60 Hz Power consumption ISS active Idle Full output short term 1 W 11 W 200 W 1032C Analog signal input connector XLR female balanced 10 kOhm Max...

Page 8: ...enelec Inc 7 Tech Circle Natick MA 01760 USA Phone 1 508 652 0900 Fax 1 508 652 0909 Email genelec usa genelec com In China please contact Beijing Genelec Audio Co Ltd B33 101 Universal Business Park No 10 Jiuxianqiao Road Chaoyang District 100015 Beijing China Phone 86 10 5823 2014 400 700 1978 Email genelec china genelec com In Sweden please contact Genelec Sverige Ellipsvägen 10B P O Box 2306 S...

Reviews: