Genave Electronics
System ID = 7654
RF Channel = 6
Encryption Key = 13579
Unit ID = 1
Antenna Requirements
There are a few items to remember about the antenna.
1) Keep the antenna away from metal surfaces for the best RF signal range.
2) For long antenna cable runs, use LMR-400 coaxial cable with adapters.
3) Never exceed 11dbi of antenna gain without some sort of cable loss (FCC
requirement).
Note: If an LR900 is out of range of its group, any LR900 can be used as a repeater to
extend the range of the signals and reach the lone LR900.
Returning to Factory Defaults Using Menu Screen
The LR900
’s can be restored to their factory default programming at any time by using the
menu screen. Returning to the factory default is the recommend method to recover from
programming errors or other events such as when a unit is not communicating within the
group.
After defaults have been restored, basic communications can be verified and custom changes
can continue from that basic, known state.
The Factory Defaults
To restore the defaults, Press the
DOWN
arrow until the
Adjustments
screen appears, then
press the
RIGHT
arrow once and then press the
DOWN
arrow to select
Reset Memory
.
Press
ENTER
key and use the
LEFT, RIGHT, UP
and
DOWN
keys to enter 987. Press
ENTER
key to restore LR900 to factory default settings.