800mm
Picture 1
. Placing the mounting
brackets
Wall
Holder
Fastener
Picture 2
.
Place unit by sliding wall
mount into metal holder
on back of unit
GENANO 310 Back panel
Wall
mount
WALL MOUNTING
It is possible to mount the GENANO 310 unit on the wall using brackets provided by Genano.
Simply fasten the mounts to a wall capable of supporting 70kg by placing both brackets on the wall
vertical to each other and 800mm apart from the metal mount
(picture 1)
.
Then simply slide the unit onto the wall mounts taking care that the metal tab slides into the hold-
ers on the back of the 310 unit
(picture 2)
OPERATION OF THE DEVICE
NORMAL OPERATION
Genano 310 is cleaning air when OK-light is illuminated.
The device efficiently collects atmospheric particles on the collection surfaces. Washing of
the collection surfaces takes place automatically once a week.
Important! It is recom-
mended to let the unit be continuously ON to ensure the weekly washing.
During the flushing of the collection surface the green
“WASH”
light is on. After the flushing
cycle has ended the GENANO310 starts its drying period. During the drying cycle the 310 is
silent and the green
“WASH”
light on.
Do not open the door immediately after the wash cycle. Allow time for the washing liquid
to drain into the basin.
WARNING ! Due to its mode of operation the electronic air purifier may occasionally emit sparks.
Never use the air purifier in a place where flammable gases or liquids or large amounts of dust may
combine with air to form an explosive mixture.