![Gemu 653 Maintenance & Operating Manuallines Download Page 9](http://html1.mh-extra.com/html/gemu/653/653_maintenance-and-operating-manuallines_2208097009.webp)
VMS - Rev.02
26.04.2004
9
Torque Guidelines
Seat
Thread
Units
Min
Max
Min
Max
8
1/2"
4x M 4
[Nm]
0.6
0.8
0.8
1.2
22 x 22
[lbf-in]
5.3
7.1
7.1
10.6
10
3/4"
4x M 5
[Nm]
3
4
3.5
4.5
44 x 39
[lbf-in]
27
35
30
40
25
1"
4x M 8
[Nm]
6.5
8
13
16
54 x 46
[lbf-in]
58
72
115
140
40
1 1/2"
4x M10
[Nm]
12
14
24
28
70 x 65
[lbf-in]
107
125
215
250
50
2"
4x M12
[Nm]
17
19
34
38
82 x 78
[lbf-in]
152
169
300
340
80
3"
4x M16
[Nm]
50
60
100
120
127 x 114
[lbf-in]
445
534
890
1070
100
4"
8x M12
[Nm]
40
50
80
100
LK 194
[lbf-in]
356
445
700
890
125
5"
8x M16
[Nm]
50.0
60
100
120
[lbf-in]
445
534
890
1070
150
6"
8x M16
[Nm]
50
60
100
120
[lbf-in]
445
534
890
1070
EPDM
PTFE
Standard values for sealing material
Seat
Actuation Type
8
601, 602, 603, 605, 618, 640, 641, 650
10
612, 615, 618, 625, 640, 650, 653, 654
620, 640, 650, 653, 654, 671, 672, 673
675, 687, 688, 695, 698
25-150
The specified torques are standard values for
A2 70 screws with light PTFE film.
After
repeated maintenance cycles
, the
torques necessary for tightening may increase
significantly.
As diaphragms may set in the course of time,
the nuts and bolts on the body should be
checked for tightness and re-tightened if
necessary before commissioning the valve (and
certainly after the
first sterilization cycle
).
The fasteners must be
tightened diagonally
and uniformly. Over-tightening of the screws
will damage the diaphragm.
Summary of Contents for 653
Page 1: ...VMS Rev 02 26 04 2004 1 Aseptic Diaphragm Valves Maintenance Operating Guidelines ...
Page 11: ...VMS Rev 02 26 04 2004 11 Diaphragm Compression Extreme ...
Page 12: ...VMS Rev 02 26 04 2004 12 Diaphragm Compression Excessive ...
Page 13: ...VMS Rev 02 26 04 2004 13 Optimum Compression ...
Page 15: ...VMS Rev 02 26 04 2004 15 Optimum Compression ...