Installing the Diaphragm
(Concave)
•
Type 1:
Screw the diaphragm clockwise into the compressor so that the cylindrical boss
around the diaphragm stud fits into the recess of the compressor. When contact (resistance)
is felt, turn the diaphragm back (counterclockwise) until the bolt holes in the diaphragm and
bonnet flange are correctly aligned.
Do not continue to tighten.
•
Type 2:
Place the button of the diaphragm at an angle so that part of the button fits in the
recess of the compressor. Push firmly in the center of the diaphragm while turning it back
and forth until the button seats in the compressor