UCL-520 Two-Wire
Ultrasonic Level Transmitter
Owner’s Manual

Version C
© 2008 Gems Inc.
All rights reserved.
Manual # 226009

IP

67

Gems Warranty

Gems warrants to the original purchaser of its products that such products 
will be free from defects in material and workmanship under normal use 
and service for a period which is equal to the shorter of one year from the 
date of purchase of such products or two years from the date of manufac-
ture of such products.

This warranty covers only those components of the products which are 
non-moving and not subject to normal wear. Moreover, products which are 
modified or altered, and electrical cables which are cut to length during 
installation are not covered by this warranty.

Gems’ obligation under this warranty is solely and exclusively limited to the 
repair or replacement, at Gems’ option, of the products (or components 
thereof) which Gems’ examination proves to its satisfaction to be defective. 
Gems SHALL HAVE NO OBLIGATION FOR CONSEQUENTIAL DAMAGES 
TO PERSONAL OR REAL PROPERTY, OR FOR INJURY TO ANY PERSON.

This warranty does not apply to products which have been subject to 
improper use, accident, negligence, abuse or misuse. Abuse shall be assumed 
when indicated by electrical damage to relays, reed switches or other 
components. The warranty does not apply to products which are damaged 
during shipment back to Gems’ factory or designated service center or 
are returned without the original casing on the products. Moreover, this 
warranty becomes immediately null and void if anyone other than service 
personnel authorized by Gems attempts to repair the defective products.
Equipment sold by Gems Sensors Inc. not intended for use in a nuclear 
installation, nor shall it be used as a “Basic Component” as same as defined 
under Part 21, Title 10 of the Code of Federal Regulations. In the event 
of such use, you agree to indemnify and hold us harmless from any and all 
subsequent liabilities and responsibilities which might arise in connection 
with such use.

Return Policy

Returns are accepted on stock items up to 30 days from date of order. 
You must contact our Returns Department for a Return Authorization (RA) number. Return the goods – freight prepaid – in the original container and include 
original packing slip. C. O. D. returns are not accepted. Gems reserves the right to apply restocking charges.

Gems further reserves the right to unilaterally waive this warranty and to dispose of any product returned to Gems where:

a. There is evidence of a potentially hazardous material present with or on the product.
b. The product has remained unclaimed at Gems for longer than 30 days after dutifully requesting disposition of the product from the Customer.

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This warranty and the obligations and li-
abilities of Gems under it are exclusive and instead of, and the original purchaser hereby waives all other remedies, warranties, guarantees or liabilities, express or 
implied. EXCLUDED FROM THIS WARRANTY IS THE IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTICULAR PURPOSE OR USE AND THE 
IMPLIED WARRANTY OF MERCHANTABILITY OF THE PRODUCTS.

Important Points:

• Gems products must be maintained and installed in strict accordance with the National Electrical Code and the applicable Gems product instruction Bul-
letin that covers installation, operation and proper maintenance. Failure to observe this information may result in serious injury or damages.
• The supply voltage to the sensor should not exceed 36 VDC, Max.
• Please adhere to the pressure and temperature limitations shown. These limitations must not be exceeded. These pressures and temperatures take into 
consideration possible system surge pressures/temperatures and their frequencies.
• Selection of materials for compatibility with the media is critical to the life and operation of Gems products. Take care in the proper selection of materials 
of construction, testing is required.
• Avoid over tightening when mounting.
• Life expectancy of switch contacts varies with application. Contact Gems if life cycle testing is required.
• Ambient temperature changes do affect switch set points, since the gravity of a liquid can vary with temperature.
• Our sensors have been designed to resist shock and vibration. However, shock and vibration should be minimized.
• Electrical entries and mounting points in an enclosed tank may require liquid/vapor sealing.
• Our sensors must not be field-repaired.
• Physical damage sustained by product may render it unserviceable. 

This warranty may not be extended, altered or varied except by a written instrument signed by a duly-authorized officer of Gems, Inc.

Part Number 225200

Summary of Contents for UCL-520

Page 1: ...d include original packing slip C O D returns are not accepted Gems reserves the right to apply restocking charges Gems further reserves the right to unilaterally waive this warranty and to dispose of...

Page 2: ...ut 4 20 mA two wire Signal invert 4 20 mA 20 4 mA Calibration Push button Fail safety Selectable 4 mA 20 mA 21 mA 22 mA or hold last value Process temp F 4 to 140 C 20 to 60 Temp comp Automatic Electr...

Page 3: ...iring and Electrical A supply voltage loop power of 12 28 VDC is used to power the UCL 520 transmitter The sensor circuit should never exceed a maximum of 28 volts DC Electrical wiring of the sensor s...

Page 4: ...ort period of time this message will disappear and be replaced by a numeric value B FULL Level has reached the programmed FULL set point C EMPTY Level has reached the programmed EMPTY set point D UNIT...

Page 5: ...POWER Displays the present acoustic power level AA MOUNT Displays either QUIET no fitting noise or NOISY potential fitting noise If NOISY with transmitter performance issues please contact Gems to di...

Page 6: ...MinR E Change Display Mode To change the display to indicate the height of liquid follow the instructions below 1 Press the SELECT FAST button and hold it for 5 seconds until PROG appears 2 When UNITS...

Page 7: ...LECT FAST button The dis play will rotate between HEIGHT FILL H and REV mA 3 When HEIGHT appears press the SELECT FAST button The display will show a decimal reading in the selected UNITS 4 Press the...

Page 8: ...ique that allows the user to enter the present distance from the transducer face to the liquid or a reflective target as the 20 mA FULL set point EMPTY Target calibration technique that allows the use...

Page 9: ...in a 2 5 cm riser 3 Stand Pipe A stand pipe may be used to dampen turbulence or separate surface foam Select a minimum 3 pipe for the stand pipe The pipe length should run the measure ment span Cut a...

Page 10: ...FAST SELECT FAST SELECT FAST TROUBLESHOOTING Transmitter UCL 520 4 mA Setting 26 2 8m 20 mA Setting 8 20 cm Factory Set Points Power Supply Power Supply 20 mA 4 mA mA 4 5 6 mA 19 20 21 Red Black Red...