GemOro PRO-M 3 Manual Download Page 7

GEM

ORO PRO-M 3

12

13

remove the battery compartment 
door located on the end of the 
PRO-M 3 by using your thumb 
to slide the textured area down 
and in the direction of the 
arrow 

E

. Remove the NiMH 

rechargeable batteries while 
making note of the polarity 
positioning on batteries.  Then 
insert (3) high-quality AAA 1.5V 
alkaline batteries into the battery 
compartment. The proper polarity 
positioning is indicated on the 
side of the battery compartment 
wall showing the direction of 
positive (+) and negative (-) 
polarity 

F

. Always be certain 

that the batteries are correctly 
positioned in the battery holder. 
Then carefully replace the 
battery compartment door.

2.   The PRO-M 3 batteries may 

be charged by placing it in the 
optional UltraDock 3 battery 
charging station with the micro-
USB power cord plugged into the 
rear of the charging station or by 
plugging its supplied micro-USB 
power cord into the rear of the 
tester and the USB adapter cube 
directly into a wall outlet. Once 
the tester is connected to the AC 
adapter or the charging station, 
the tester will switch to its DC 
power mode. The tester’s built-in 
Intelligent Charging Circuit ICC 
will automatically identify the 
type of batteries installed (NiMH 
rechargeable batteries or alkaline 
batteries). If alkaline batteries 
are installed, the circuit will 
automatically cut off the power 
supply to the batteries so that 
the alkaline batteries will not be 
recharged. If NiMH rechargeable 
batteries are installed, the 
batteries will be recharged and 
at the same time the tester may 
be used with the AC adapter.

3.  To turn the PRO-M 3 ON press 

the oval shaped power button, 
located on the top center edge 

BATTERY POLARITY

F

TESTER BATTERY COMPARTMENT

E

BATTERY DISCHARGE INSULATOR TAB

D

Summary of Contents for PRO-M 3

Page 1: ...MOISSANITE TESTER WITH NEW ADVANCED PATENTED UV F1 IDENTIFICATION TECHNOLOGY PRO M 3 ...

Page 2: ...ajority of moissanite may be electrically conductive in some moissanite gemstones there might only be electrical conductivity in varying degrees Further with the READ BEFORE USING A high percentage of the new generation super low electrically conductive Forever One or F1 moissanite that was introduced in late 2015 will incorrectly be identified as diamond when tested on a traditional combination e...

Page 3: ...d separating the stone in question The PRO M 3 is an advanced technologically based tool IMPORTANT DISCLAIMER The PRO M 3 is a helpful screening tool that by design is to be used as a quick method for helping to identify moissanite The PRO M 3 should not be used as the final method for determining the authenticity or identity of the gemstone being tested The final determination of the identity of ...

Page 4: ...sted with an ultrasonic or steamer or other appropriate means and thoroughly dry it and or remove any cleaning chemicals remaining on the stone prior to testing A GemOro STONE TESTING CLOTH shown below has been provided with each PRO M 3 and for convenience it should be used to wipe any hand or body oil from the stones surface prior to testing 4 It is imperative that the probe tip be cleaned regul...

Page 5: ... is also designed to have its batteries charged with the optional GemOro UltraDock 3 charging station accessory Item 0772 9 Includes a GemOro protective ballistic nylon carrying case aluminum loose stone holder GemOro Test Stone Cloth as well as 3 user replaceable AAA NiMH rechargeable batteries a universal multi voltage 100V 240V AC adapter charger cube with premium micro USB cord 10 The tester i...

Page 6: ...rking Temperature 65 F 80 F 18 C 27 C Air Relative Humidity 45 75 Net Weight Approximately 100g including batteries CAUTION DO NOT disassemble the PRO M 3 other than to replace the batteries or the warranty will become void OPERATION 1 NiMH Battery Usage and Alkaline Battery Installation To activate the 3 NiMH rechargeable batteries REMOVE THE BATTERY DISCHARGE INSULATOR TAB D that is extending ou...

Page 7: ...the micro USB power cord plugged into the rear of the charging station or by plugging its supplied micro USB power cord into the rear of the tester and the USB adapter cube directly into a wall outlet Once the tester is connected to the AC adapter or the charging station the tester will switch to its DC power mode The tester s built in Intelligent Charging Circuit ICC will automatically identify t...

Page 8: ...g their eyes on the stone being tested BLUE Moissanite RED Metal Alert 6 Prior to using the PRO M 3 be certain to REMOVE THE WHITE CAP at the front end of the tester that serves to protect the probe tip from accidentally being bent or broken H The cap may be easily removed by simply applying a minimal amount of pressure to the sides of the cap as you hold it between your thumb and forefinger Then ...

Page 9: ...stone you wish to test and in your other hand hold the PRO M 3 K NEVER TEST A RING WHILE PLACED IN A RING BOX OR IT MAY NOT TEST CORRECTLY Quickly yet firmly touch the testers probe tip to the stone s table while being certain not to allow the probe tip to make contact with the metal setting or prongs While firmly depressing the retractable probe tip all of the way in until you hear a click sound ...

Page 10: ...Using the Optional UltraDock 3 Place the charging station in a convenient location near where it will be used such as on a desk showcase or repair area Take the testers micro USB power cord and plug it into the rear of the UltraDock 3 while plugging the USB into its AC power cube adapter Plug the adapter into a convenient wall outlet You may now simply place the PRO M 3 in the charging stations cr...

Page 11: ...s not used for an extended period of time the batteries should be removed 5 Routinely clean the probe tip 6 The PRO M 3 is not user serviceable other than battery replacement probe tip cleaning and recalibration If service is required please contact your supplier or the factory Any other attempt to repair the tester by a user will void the warranty HELPFUL SUGGESTIONS 1 If substituting alkaline ba...

Page 12: ...number tracking system as interpreted by the factory In the event the PRO M 3 is no longer available or has been discontinued and warranty coverage is applicable at the factory s sole discretion an equivalent tester may be substituted for the defective PRO M 3 The purchaser shall incur the cost for postage insurance and handling for all warranty and non warranty repairs Warranty repairs and or rep...

Page 13: ...truments 10455 Olympic Drive Dallas Texas 75220 USA 214 351 0380 or 800 527 0719 214 351 1903 or 800 832 9871 FAX gemoroservice sykessler com www gemoroproducts com warrantyregistration www gemoroproducts com 2018 SKS Inc ...

Reviews: