MOISSANITE TESTER
WITH NEW ADVANCED
PATENTED UV-F1
IDENTIFICATION
TECHNOLOGY
™
Page 1: ...MOISSANITE TESTER WITH NEW ADVANCED PATENTED UV F1 IDENTIFICATION TECHNOLOGY PRO M 3 ...
Page 2: ...ajority of moissanite may be electrically conductive in some moissanite gemstones there might only be electrical conductivity in varying degrees Further with the READ BEFORE USING A high percentage of the new generation super low electrically conductive Forever One or F1 moissanite that was introduced in late 2015 will incorrectly be identified as diamond when tested on a traditional combination e...
Page 3: ...d separating the stone in question The PRO M 3 is an advanced technologically based tool IMPORTANT DISCLAIMER The PRO M 3 is a helpful screening tool that by design is to be used as a quick method for helping to identify moissanite The PRO M 3 should not be used as the final method for determining the authenticity or identity of the gemstone being tested The final determination of the identity of ...
Page 4: ...sted with an ultrasonic or steamer or other appropriate means and thoroughly dry it and or remove any cleaning chemicals remaining on the stone prior to testing A GemOro STONE TESTING CLOTH shown below has been provided with each PRO M 3 and for convenience it should be used to wipe any hand or body oil from the stones surface prior to testing 4 It is imperative that the probe tip be cleaned regul...
Page 5: ... is also designed to have its batteries charged with the optional GemOro UltraDock 3 charging station accessory Item 0772 9 Includes a GemOro protective ballistic nylon carrying case aluminum loose stone holder GemOro Test Stone Cloth as well as 3 user replaceable AAA NiMH rechargeable batteries a universal multi voltage 100V 240V AC adapter charger cube with premium micro USB cord 10 The tester i...
Page 6: ...rking Temperature 65 F 80 F 18 C 27 C Air Relative Humidity 45 75 Net Weight Approximately 100g including batteries CAUTION DO NOT disassemble the PRO M 3 other than to replace the batteries or the warranty will become void OPERATION 1 NiMH Battery Usage and Alkaline Battery Installation To activate the 3 NiMH rechargeable batteries REMOVE THE BATTERY DISCHARGE INSULATOR TAB D that is extending ou...
Page 7: ...the micro USB power cord plugged into the rear of the charging station or by plugging its supplied micro USB power cord into the rear of the tester and the USB adapter cube directly into a wall outlet Once the tester is connected to the AC adapter or the charging station the tester will switch to its DC power mode The tester s built in Intelligent Charging Circuit ICC will automatically identify t...
Page 8: ...g their eyes on the stone being tested BLUE Moissanite RED Metal Alert 6 Prior to using the PRO M 3 be certain to REMOVE THE WHITE CAP at the front end of the tester that serves to protect the probe tip from accidentally being bent or broken H The cap may be easily removed by simply applying a minimal amount of pressure to the sides of the cap as you hold it between your thumb and forefinger Then ...
Page 9: ...stone you wish to test and in your other hand hold the PRO M 3 K NEVER TEST A RING WHILE PLACED IN A RING BOX OR IT MAY NOT TEST CORRECTLY Quickly yet firmly touch the testers probe tip to the stone s table while being certain not to allow the probe tip to make contact with the metal setting or prongs While firmly depressing the retractable probe tip all of the way in until you hear a click sound ...
Page 10: ...Using the Optional UltraDock 3 Place the charging station in a convenient location near where it will be used such as on a desk showcase or repair area Take the testers micro USB power cord and plug it into the rear of the UltraDock 3 while plugging the USB into its AC power cube adapter Plug the adapter into a convenient wall outlet You may now simply place the PRO M 3 in the charging stations cr...
Page 11: ...s not used for an extended period of time the batteries should be removed 5 Routinely clean the probe tip 6 The PRO M 3 is not user serviceable other than battery replacement probe tip cleaning and recalibration If service is required please contact your supplier or the factory Any other attempt to repair the tester by a user will void the warranty HELPFUL SUGGESTIONS 1 If substituting alkaline ba...
Page 12: ...number tracking system as interpreted by the factory In the event the PRO M 3 is no longer available or has been discontinued and warranty coverage is applicable at the factory s sole discretion an equivalent tester may be substituted for the defective PRO M 3 The purchaser shall incur the cost for postage insurance and handling for all warranty and non warranty repairs Warranty repairs and or rep...
Page 13: ...truments 10455 Olympic Drive Dallas Texas 75220 USA 214 351 0380 or 800 527 0719 214 351 1903 or 800 832 9871 FAX gemoroservice sykessler com www gemoroproducts com warrantyregistration www gemoroproducts com 2018 SKS Inc ...