- 8 -
TECHNICAL SPECIFICATIONS
* A 3m (9.8 ft) horizontal or vertical concentric flue connection increases in efficiency by about 2 %.
2 - DIAMETERS OF PIPE CONNECTIONS
* Note:
- The F3/4"-F3/8" reduced bend supplied with the
boiler makes it possible to assemble the 3/8"
bleed supplied (refer to section 7 - page 25 -
chapter V - INSTALLATION).
Useful capacity (for static height of 5m (197 inch))
litre
gallon
5
1.3
7,5
2
Power consumption (Continuous working with heating circulating
pump at maximum speed)
W
HP
235
0.32
235
0.32
Power consumption with heating circulating pump
Speed 1
Speed 2
Speed 3
W/HP
W/HP
W/HP
45/0.06
65/0.09
85/0.11
Power absorbed (with burner, without circulator)
W
HP
150
0.2
150
0.2
Power supply / Protection index
120 V - 60 Hz / IP x 0D
Class of electrical insulation
1
Absorbed intensity
maxi
A
1,9
1,9
Weight without packaging
kg
Lb
132,4
292
157,3
347
Weight with packaging
kg
Lb
146
322
167,5
369
Model
FCX
Ø
Combustion products
mm
inch
80/125
3.15/4.92
Ø
Heating flow/return
Inch
1
Ø
Domestic hot water production system or 2
nd
heating circuit connection
Inch
1
Ø
Condensate drain
mm
Inch
40
1-1/2
Ø
Heating water drain
Inch
1/2
Ø
Air bleed
Inch
3/4
Model
FCX 22 C
FCX 30 C