X
GEM-P3200 Programming Instructions
L
NAPCO Security Systems
WI818D 08/00
!
Page 26
!
Press
J
to save each code.
To proceed to the next User Code, set the cursor to the User Number and change it using the number buttons. Program
a new User Code as previously described. Press NEXT (
E
) button to proceed.
GEM-RP3DGTL Key
p
ad: User Codes
Example:
Program a code of “2222” for user 02, with User Option of “User Program”, User “Level 3” and Access Control Option
“Keypad No. 1”. Enter “2222” for a user code, “2 3” for user option and “blank(•) 1” for access control option.
CHANGING OR CANCELING A CODE:
To change any code, merely program over the existing code as described above
and press
J
to save. Similarly, to cancel a code, blank out each number of the code press
J
to save to save.
USER AUTHORITY LEVEL
KEYPAD DISPLAY FUNCTION MENU
FUNCTION
LEVEL*
DISPLAY ZN FAULTS
1
DISPLAY ZN BYPASSED
1
DISPLAY ZN DIRECTORY
1
ACTIVATE BELL TEST
1
DISPLAY PHONE #’S
1
DISPLAY SYS TRBL
1
DISPLAY FIRE ALARM
1
DISPLAY FIRE TRBL
1
DISPLAY OP/CL
3
ACTIVATE OVERVIEW
3**
ACTIVATE CHIME
1
ACTIVATE WATCH
2
RESET SYSTEM TRBL
3
RESET SENSOR MSG
3
START EXIT TIME
1
FAULT FIND
***
ACTIVATE LOCATE
***
EZM ZONE FIND
***
ACTIVATE DIALER TEST
3
DISPLAY ALARM LOG
3
DISPLAY TOTAL LOG
3
DISPLAY FIRE LOG
3
DISPLAY OP/CL LOG
3
DISPLAY SYSTEM LOG
3
AUTOARM IN 1-4HRS
2
DISPLAY AUTARM SCHD
3
ACTIVATE PROGRAM
3**
ACTIVATE DOWNLOAD
3
DISPLY RF XMITTER STAT
1
RELAY CONTROL
1
NOTES:
*
Minimum Level required to access function
** Level-3 Code with appropriate user option
*** Requires Dealer Code
Related User Options:
Ambush Code” (Address 0495), “Panel Access Code” (Address 0490),
“Dealer Security Code” (Address 0500) & “Enable User Code by Area” (Address 2500-2547).
USER OPTIONS
OPTIONS
EXPLANATION
Disabled
User Code not active in this area.
Blocked View
Allows User Code to block another code from being viewed by another user.
An unblocked code cannot view a blocked code, but a blocked code can view
all codes. The master user code and the dealer program code can view all
codes.
User Program
User Program Option is enabled for Keypad 1 only, wherever it is connected
(any area). If enabled, Level 3 must also be enabled.
Bypass
Allows User Code to bypass zones.
Overview
This option, along with Level 3 Authorization, enables selection of OVERVIEW
mode at a keypad. This Mode provides a system status display of all areas at a
glance.
Arm Only
Prevents User Code from disarming this area.
Service
A Service Code has restricted arm/disarm rights; if an area is armed with a
Service Code, a “
SERVICE ON
” appears on the GEM-RP2ASe2 keypad (a “
S
” on
the GEM-RP1CAe2 keypad) and the area can be disarmed with any valid User
Code, including a Service Code. If the area is armed with OTHER than a
Service Code, it CANNOT be disarmed with a Service Code. This is typically
used to allow tradesmen access to premises under control of the owner.
Access
This is normally used to activate a door striker while an area is disarmed. A
code with the access option will not function as an arm/disarm code. When the
code is entered, the keypad will display “
ENTER NOW
” and the Brown Wire on
the keypad will become Active Low (Ground Potential) for 7 seconds.