INSTALLER MANUAL

8.1 - YELLOW LED SIGNAL INDICATIONS

8.0 - SIGNAL SYMBOLS

S Y M B O L

Y E L L O W

L E D

C O L O R

A C O U S T I C

A L E R T

G r e e n

N o n e

C o n s e c u t i v e

f l a s h i n g s

R e d

N o n e

O n s t e a d y

Ye l l o w

S h o r t b e e p

e v e r y 5 m i n u t e s

O n s t e a d y

S u p p l y v o l t a g e p r e s e n t

S t a r t i n g a n d w a r m i n g u p

Power ON - alarm ON

Faulty

Signaling of specific functional conditions

(see table 8.1)

Out of order due to exhaustion of

probe (after 11,000 working hrs)

D E S C R I P T I O N

D E T E C TO R

C O N D I T I O N

!

PAGE 06 - USER MANUAL

10.0 - INSTALLATION

10.1 -FITTING OF DETECTOR

10.2 - ELECTRICAL CONNECTIONS

10.3 - MOUNTING DIAGRAM

The 911 detector is intended for a permanent installation.
The device must be positioned at about 20-40 cm from the vehicle cabin floor
to be protected.
The detector must be installed at least 1-1,5m away from any air supply
register; if there is an air intake vent, install the detector near it.

Remove the detector cover by prying lightly with a screwdriver inserted in
the release slot on the right side of the casing.

The two screw holes (FF) can be used to mount the detector to a wall or
onto a base (fig.1); the electronic card must first be removed by unscrewing
the screw on the bottom right corner. (see par.

).

The pre-drilled holes (FC) are used to run the power wiring (see par.

).

Connect the wires that supply 12 or 24V to the terminal block M2 (see par.

; depress the supply terminal block to introduce the cables which must

have a section comprised between 0,5 and 1,5 mm².

Remove 9mm of sleeve from the cable before inserting it in the terminal
block; release the push-button and pull on the cable to make sure it is well
secured.

The auxiliary devices conductors intended to manage the alarm must be
connected to terminal block M1; the maximum rating of the relay contacts is
2A at 28Vdc (refer to par. 13). To actuate devices having a higher
absorption rate, an auxiliary relay must be provided.

!

!

!
!

!

!

13

12.0

12)

INSTALLER MANUAL - PAGE 07

9.0 -

WARRANTY CONDITIONS

This product is guaranteed to be free from defects in workmanship for a period
of 24 months from the date of installation reported on the present warranty, in
compliance with the1999/44/CE Warranty Directive (L.D. N° 24 -
02/02/2002).
Please fill-in entirely the guarantee certificate included in this manual and DO
NOT REMOVE the guarantee label affixed to the device.
The warranty will become void if labels are missing or torn, if the installation
certificate is not fully compiled or if the enclosed sale document is missing.
The warranty is valid exclusively at authorized Gemini Technologies centers.
The manufacturer declines any responsability for eventual malfunctions of the
detector or any damage to the vehicle electrical system due to improper
installation, use or tampering.

FC

FC

FC

FF

FR

Figure 1

FF -

FC -

FR -

Pre-drilled mounting holes, use the

ones to the far ends.

Pre-drilled holes to run the cables,

use the ones on the left for the power
cable.

Power supply cable holder.

Summary of Contents for 911

Page 1: ... com Reg n 532 A AC 2782UK Rev 00 12 09 UK INSTALLATION AND USE MANUAL INSTALLATION CERTIFICATE The undersigned qualified installer attests to have personally fitted the here described detector on the following vehicle according to the manufacturer s instructions By Sold on Type of device Vehicle Narcotic Gas and Explosive Wireless Detector Gas 911 911 ...

Page 2: ...ave any effect on the occupants N B In compliance with European standard En50194 the detector can signal the presence of explosive gas LP when its concentration is higher than 10 of the LEL Lower Explosive Limit the minimum concentration which can cause an explosion The 911 detector also activates the output relay which actuates other devices ex cabin lights vehicle horn etc to discourage anyone t...

Page 3: ...alarm device The relay supplies the contacts NC C NO on the terminal block M1 see connection example in par 11 5 0 SELF DIAGNOSIS The detector is provided with an acurate and reliable self diagnosis system which continuously checks its performance and efficiency any failure or the exhaustion of the probe after a life cycle of more than 11 000hrs is signaled by the yellow LED turning ON and by a wa...

Page 4: ... introduce the cables which must have a section comprised between 0 5 and 1 5 mm Remove 9mm of sleeve from the cable before inserting it in the terminal block release the push button and pull on the cable to make sure it is well secured The auxiliary devices conductors intended to manage the alarm must be connected to terminal block M1 the maximum rating of the relay contacts is 2A at 28Vdc refer ...

Page 5: ...the detector contacts PAGE 08 INSTALLER MANUAL 12 0 CIRCUIT DIAGRAM 13 0 CORRECT POSITION FOR LPG DETECTION INSTALLER MANUAL PAGE 09 The detector must be installed at about 20 40cm from the floor as illustrated here below Min 1 meter Max 5 meter 20 40 cm Model 911 M1 M2 SL1 P1 Screw type terminal block to connect alarm output contact Push button type terminal block for 12V or 24V Voltage switch 12...

Page 6: ... casing and inflammability class Approximate weight Relay contact rating APPROPRIATE CONTAINERS ONLY 15 0 WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT DIRECTIVE WEEE In the European Union this label indicates that this product must not be disposed of with household waste It should be deposited at an appropriate facility to enable recovery and recycling Directives 2002 95 CE 2002 96 CE and 2003 108 CE...

Reviews: