INSTALLER MANUAL - PAGE 11
PAGE 10 - INSTALLER MANUAL
10.7 -
).
NEGATIVE OUTPUT SELECTION (DURING ALARM) FOR HORN OR ADDITIONAL
SIREN
Depending on the connection made, this feature can activate the output for the siren (continuous tone)
or for the horn (intermittent tone
10.0 - SYSTEM PROGRAMMING
The t
E
.
able below applies to the system programmed in “standard configuration”.
very time you enter the programming procedure, the alarm resets to the default settings
When the optical pulse signal feature is enabled, the blinkers will ONLY flash during an
alarm cycle.
The system BLUE wire MUST be connected to the Hazard wire.
In this case, do not connect the ORANGE wires (see chapter 7.3).
!
FUNCTION
STATUS
LED FLASHES
Disabled
Enabled
D
D
D
D
D
isabled
isabled
isabled
isabled
isabled
“Exclusion” of arming/disarming optical signals
“Exclusion” of arming/disarming acoustical signals
Passive arming
Arming of self-powered coded siren
Boot input, positive signal
Optical pulse signals (Hazard)
Pulse negative output during alarm cycle
“
A lack of power during electrical system maintenance will not affect the programming.
The procedure must be carried out entirely. To scroll from one feature to another either turn ignition key
to disable it or use the electronic key to enable it (see par.11.0).
Programmable features are briefly described below.
This feature enables the optical arm/disarm signals.
10.1 - OPTICAL SIGNALS
If the vehicle already has optical lock/unlock signals, the turn indicator alarm flashes
should be disabled
10.2 - ACOUSTIC SIGNALS
10.3 - PASSIVE ARMING
10.4 - ENABL
10.5 - BOOT SWITCH POLARITY SELECTION
10.6 - OPTICAL PULSE SIGNAL OR SELF-POWERED SIREN
This
.
.
(P/N 7725).
This feature modifies the alarm input signal (positive or negative) according to the signal generated
.
The output can be used to enable the optical
. Or it can be used to manage a self-powered siren.
feature enables the acoustic arm/disarm signals
This feature automatically arms the system 60” after ignition is switched off and the last door is opened
and closed.
If a door is opened during this lapse of time, the procedure is interrupted; it will resume when the door
is closed
by
the boot switch
signals (according to the connection made); only for
vehicles where the hook-up is to the Hazard switch
ING OF SIREN (P/N 7725) OUTPUT
This feature enables the relative output (20-pin connector, position 13, PINK wire) to activate the self-
powered coded siren
!
11.0 - SYSTEM PROGRAMMING EXAMPLE
10.0).
The following example illustrates the steps to follow to modify the programmable features.
As previously mentioned, turning the key OFF/ON disables the feature, while using the electronic key
enables it. To confirm the operation, a Beep or a Boop will sound and the LED will flash as indicated
(see table, chapter
In both cases, the system moves on to the next feature.
Repeat the above steps to enable or disable the other features.
When the last feature is configured (either with the electronic key or the ignition key), the
confirmation tone will be followed by 2 Boops and 1 Beep and 2 flashes of the turn indicators to
confirm the end of the programming procedure.
With the alarm system disarmed, turn ignition key “ON”.
ON
Two acoustic signals (1 Beep and 1 Boop) and 2 flashes of the turn indicators will confirm that the
system is in programming mode.
OFF-ON
Boop
Beep
To
the feature, t
disable
urn ignition “OFF” and
then back “ON” .
A low-pitched acoustic signal will confirm the
operation.
The LED will flash according to the selected
feature (from 1 to 7).
OR
To
the feature, touch the electronic key
once to its receptacle.
A high-pitched acoustic signal will confirm the
operation.
The LED will flash according to the selected
feature (from
enable
1 to 7).
The LED will light up for approx. 2 seconds; while the LED is ON,
.
touch the electronic key to
its receptacle
If the feature is disabled, under normal operating conditions, the blue wire carries a negative signal;
during an alarm cycle, there is a lack of negative.