Presetting the fixed power in constant power operation mode 

 

The power or flow is shown in percentage of the maximum power 
rating or flow rating. In constant power operation mode or constant 
flow operation mode, press the button "1", "2" or "3" of the fixed 
value which is to be changed and the LED window displays the current 
power percentage, then keep the "SET" button pressed for at least 
three seconds until the speed displayed in the LED window begins to 
flash. Now the power percentage can be changed with the buttons 

▼▲

. Every time the button 

or 

 is pressed, the speed 

decreases or increases by 1%. The upper limit of the speed is 100% and 
the lower limit is 5%. To save the set power percentage confirm with 

"OK" button. To cancel and return to the original speed press the “SET” 

button. 
The default setting of the power or flow percentage is as below: 
1 = 60 % 
2 = 80 % 
3 = 100 % 

 

Setting the priming parameters 

 

The motor has to be stopped ("0" button) to program the priming 
speed and time. Then press the "SET" button again for at least three 
seconds until the speed displayed in the LED window begins to flash. 
Now the speed can be set with which the motor is to start up during 

the priming time. The speed can be changed with the buttons “

▼▲

the upper limit of the priming speed is 2850 rpm and the lower limit is 
1000 rpm. Press the button "OK to save the speed setting and enter 
the phase for priming time setting, or press "SET" to cancel and return 
to the previous mode. After the priming speed has been set, the 
period of the priming time can be specified with regard to a range 
from 0 to 10 minutes.  

 

Summary of Contents for RANGER

Page 1: ...GEMAS RANGER PUMP INSTRUCTION MANUAL ...

Page 2: ...complete with 5 wire cable for connection Cable colours are shown on below chart with RPM amounts Cables should be connected to dry contact Contacts must be changed seperately Otherwise speed can not be adjusted ...

Page 3: ...ming speed Priming time 2850 rpm 5 minutes Speed which can be set 1000 2850 rpm in 50 rpm per step Priming time which can be set 0 10 minutes in 1 minute per step 1 LED window displays the current speed of the motor or error code message 2 SET button used to enter the programming mode or to reset the control 3 Button 1 used to select the fixed low speed or to decrease in the programming mode 4 But...

Page 4: ...tons Every time the button or is pressed the speed decreases or increases by 50 rpm The upper limit of the speed is 2850 rpm and the lower limit is 1000 rpm To save the set speed confirm with OK button To cancel and return to the original speed press the SET button The default setting is as follows 1 2000 rpm 2 2400 rpm 3 2850 rpm Keep the SET button be pressed when turning on the ac power supply ...

Page 5: ...ge confirm with OK button To cancel and return to the original speed press the SET button The default setting of the power or flow percentage is as below 1 60 2 80 3 100 Setting the priming parameters The motor has to be stopped 0 button to program the priming speed and time Then press the SET button again for at least three seconds until the speed displayed in the LED window begins to flash Now t...

Page 6: ... the pump Manual operation Press button 1 2 or 3 to select the preset fixed speed or preset fixed power If the pump starts from standby state it starts up in priming mode and subsequently runs with the selected fixed speed or fixed power As long as the pump is in the priming phase the light of the selected speed or power flashes During running operation the pump will be accelerated or decelerated ...

Page 7: ...t least 15 seconds The three lights of the fixed speeds and the power light turn on The motor starts to run by the default preset speed after the SET button is released Power saving mode The LED display turns off in three minutes when there is no action detected either from the press buttons or from the external switches ...

Page 8: ... error 62 DSP RAM error 63 DSP watchdog error 66 Communication error with driver In case of an error occurs the Error light turns on and the LED window displays an error code The message will not be cleared until the fault is disappeared or the power supply is turned off The controller records the latest 8 errors and the error history can be viewed one by one in the LED window When a new error occ...

Reviews: