background image

GEMAŞ Genel Mühendislik Mekanik San.ve Tic.A.Ş.

 

 

         

      

İTOB Organize Sanayi Bölgesi 10001 Sok.No:28 Menderes/İZMİR TURKEY 

 

 

          Tel:0232 799 0 333 Fax:0232 799 0 330     www.gemas.com.tr   [email protected] 

ENG      GEMAS PURITRON INSTRUCTION MANUAL                       

V1.5

 

Preliminary information 

                  

 

“Thank you for your trust and support for Gemas branded products. "

 

 

GEMAŞ Salt Chlorine Generator; It has been designed and produced to perform salt electrolysis in 

small and medium-sized home pools. 

 

 

The instructions for use must be read carefully before assembly, and the 
assembly must be done by experienced technicians. Assembled in violation of 
the assembly instructions; Damages and malfunctions that may occur in 
products with electrical and water connections are not covered by the 
warranty.

 

GEMAŞ Salt Chlorine Generator is a device designed and 

manufactured for salt electrolysis only in small and medium-sized pools. Using the 
device, you purchased for other purposes; it can be dangerous both for the device and 
for the place and people using it.

 

 

 

 

Connect the ground connection to a proper grounding line. Take electrical 
power from a line with leakage current protection. 

 

 

ATTENTION! Serious injuries or even death can result from electric shock. 
Therefore, seek help from experienced technicians. 

 

In terms of life safety and product; It must be installed in places where 
children cannot reach. 

 

Installation and commissioning must be carried out by an authorized service 
or qualified electrician and plumber. Otherwise, the manufacturer and the 
seller company cannot be held responsible for the problems that may arise 
due to incorrect installation and commissioning. No repair, maintenance, and 

replacement parts can be requested under the warranty. 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Puritron GSC-102

Page 1: ...GEMAŞ Genel Mühendislik Mekanik San ve Tic A Ş İTOB Organize Sanayi Bölgesi 10001 Sok No 28 Menderes İZMİR TURKEY Tel 0232 799 0 333 Fax 0232 799 0 330 www gemas com tr info gemas com tr 1 ...

Page 2: ...y GEMAŞ Salt Chlorine Generator is a device designed and manufactured for salt electrolysis only in small and medium sized pools Using the device you purchased for other purposes it can be dangerous both for the device and for the place and people using it Connect the ground connection to a proper grounding line Take electrical power from a line with leakage current protection ATTENTION Serious in...

Page 3: ...s The risk of fatal accidents that may arise from the mixing of chlorine and acids that emit heavy gases are eliminated with this system Short storage period of purchased hypo solutions in summer conditions loss of concentration due to heat significantly increases the attractiveness of the system Besides with the high oxidation effect of the produced oxygen radicals as well as chlorine in the proc...

Page 4: ... the current at the moment of operation The device records the total working time It can be easily applied to the existing pool The minimum recommended salinity is 4000ppm 4kg m3 The device can also be used in seawater with 35000ppm 1 1 Technicial Specifications GSC102 GSC202 GSC302 Chlorine Production 10 g h 20 g h 30 g h pH Measurement Control 0 14 pH 0 14 pH 0 14 pH ORP Measurement Control 0 10...

Page 5: ...to protect the safety of life and property in the Salt Chlorine Generator For the electrical precautions to function the leakage relay and grounding warnings must be taken into consideration Leakage Current Relay Use a leakage current relay that is CE certified and you are sure that it is working Make sure the relay you will use controls the generator Strictly test the Leakage Current Relay every ...

Page 6: ...asy access and reading must be determined for mounting the control panel The control panel must be in a place with airflow protected from rain and without any water leakage hazard If there are acid tanks in the area where the control panel is located there must be airflow in the environment Otherwise electronic components may corrode with the effect of acid The control panel must be thought to be ...

Page 7: ...he electrode Electrode it must be seated in the correct direction The open part of the electrode must be inserted with the water inlet pipe connection Make sure the silicone gasket is in place and sealed tightly Connect the electrode cable through the cable choke seal and the threaded electrode head to the cable connection terminals Close the threaded electrode head It is recommended to install th...

Page 8: ... following values Salt 5 6 Kg m pH Concrete Pool 7 2 7 6 Polyester 6 8 7 0 TAC 60 100 ppm TH 15 20 French Stabilizer 20 30 ppm or manufacturer s recommendation Temperature 10 C 2 4 Adding Salt During the salt addition process the system must be closed completely until all the salt is dissolved If the system is operated before the salt is completely dissolved the cell may get irreversible damage Fo...

Page 9: ...warnings about the device are displayed 2 The device performs the functions of ON OFF switching on off entering the setting menu the device is turned off pressed for 3 seconds when it is OFF and exit the pages and parameters in the setting menu 3 Selection of the pages and parameters in the setting menu performs the functions of confirming and saving the set parameters 4 In the settings menu it pe...

Page 10: ...ange it it can be changed via ORP SETTINGS ORP MODE parameter in the Settings menu ORP mode It is AUTO Cl is produced according to the value read in the ORP sensor and the set value When the desired value is found Cl production stops automatically If it is desired to change it it can be changed via ORP SETTINGS ORP MODE parameter in the Settings menu 6 This is the part where the measured pH value ...

Page 11: ...ince the lime layer is insulating it complicates the flow of electricity between the electrodes As a result chlorine production efficiency decreases This lime formed in the electrodes must be cleaned periodically This cleaning process It has the feature to do it automatically by changing the polarization Polarity period page is the page where the polarization change time is set The OK button is pr...

Page 12: ...as AUTO in the system pH Mode AUTO When this Mode is set the dosing of the lowering or increasing liquid is done by the value read in the pH sensor and the set value Dosing stops automatically when the desired value is found 3 2 3b pH Set pH set value It is the desired pH value of the pool Dosing is done by comparing the value read with the sensors with the set value entered here Dosing pH lowerin...

Page 13: ...liquid and the sensor is left in the liquid until the timer on the screen is reset When the timer is reset the pH sensor needs to be immersed in ph7 liquid and a message appears on the screen The sensor is removed from the pH4 liquid and dried immersed in the pH7 liquid and pressed the OK button once The sensor is left in the liquid until the timer on the screen is reset When the timer is reset th...

Page 14: ...ed according to the value read in the ORP sensor and the set value When the desired value is found Cl production stops automatically 3 2 4b ORP Set ORP set value The ORP RX value that the pool must have Dosing is done by comparing the value read with the sensors with the set value entered here The dosed liquid ensures that the pool is at the desired ORP RX value The OK button is pressed once and t...

Page 15: ...spended minerals decompose from water during electrolysis some of them stick to the electrodes in the chamber After a certain period the electrodes are completely covered with the substance called lime Since the lime layer is insulating they complicate the flow of electricity between the electrodes As a result chlorine production efficiency decreases This lime formed in the electrodes must be clea...

Page 16: ...e is broken or not touching Check cable and connection terminals replace if necessary Electrode wiring problem Check electrode cable connection terminals Heavy lime Clean the lime from the cell and reduce the polarity period ERR2 There is lime Clean the lime from the cell and reduce the polarity period The water is too hard Soften the water ERR3 Device output has a short circuit Check device elect...

Page 17: ...ır GEMAŞ Tuz Klor Jeneratörü sadece küçük ve orta ölçekli havuzlarda tuz elektrolizi işlemi için tasarlanmış ve üretilmiş bir cihazdır Satın aldığınız cihazı başka amaçlar için kullanmak gerek cihaz için gerekse kullanılan mahal ve kullanan kişiler için tehlike arz edebilir Topraklama bağlantısını düzgün bir topraklama hattına bağlayınız Elektrik enerjisini kaçak akım koruması bulunan bir hattan a...

Page 18: ...ır gaz çıkartan klor ve asitlerin birbirine karıştırılmasından doğabilecek ölümcül kaza riskleri bu sistemle ortadan kalkmaktadır Satın alınan hipo çözeltilerinin yaz koşullarında depolama süresinin kısalığı sıcaktan kaynaklı konsantrasyon kaybı sistemin cazibesini önemli ölçüde arttırmaktadır Bunlara ek olarak proseste klorun yanı sıra üretilen oksijen radikallerinin yüksek oksidasyon etkisi ile ...

Page 19: ...ağlar Cihaz toplam çalışma süresini kaydeder Mevcut havuza kolaylıkla uygulanabilir Önerilen minimum tuzluluk 4000ppm dir 4kg m3 Cihaz 35000ppm olan deniz suyunda da kullanılabilir özelliğe sahiptir 1 1 Teknik Özellikler GSC102 GSC202 GSC302 Klor Üretimi 10gr saat 20gr saat 30gr saat pH Ölçüm Kontrol 0 14 pH 0 14 pH 0 14 pH ORP Ölçüm Kontrol 0 1000mV 0 1000mV 0 1000mV Besleme Voltajı 220V AC 220V ...

Page 20: ...k önlemler alınmıştır Elektriksel önlemlerin işlevini yerine getirebilmesi için mutlaka kaçak akım rölesi ve topraklama ile ilgili uyarıların dikkate alınması gerekmektedir Kaçak Akım Rölesi CE belgeli ve çalıştığından emin olduğunuz bir kaçak akım rölesi kullanın Kullanacağınız rölenin jeneratörü kontrol ettiğinden emin olun Kesinlikle her yıl Kaçak Akım Rölesini test edin Kaçak Akım Rölesinin ta...

Page 21: ...ır Kontrol panosu montajı için kolay ulaşım ve okuma sağlayacak bir yer belirlenmelidir Kontrol panosu hava akışının olduğu yağmurdan korumalı ve herhangi bir su sızıntısı tehlikesi olmayan bir yerde olmalıdır Kontrol panosunun bulunduğu bölgede asit tankları var ise ortamda hava akışı olması gerekmektedir Aksi halde asit etkisi ile elektronik komponentler korozyona uğrayabilir Kontrol panosu elek...

Page 22: ... Elektrot haznenin içine doğru yönde oturtulmalıdır Elektrotun açık kısmı su giriş borusu bağlantısına gelecek şekilde sokulmalıdır Silikon contanın yerinde olduğundan ve sızdırmayacak şekilde yerleştiğinden emin olun Elektrot kablosunu kablo boğma contasından ve rakorlu elektrot kafasından geçirerek kablo bağlantı terminallerine bağlayın Rakorlu elektrot kafasını kapatın Üç vanalı bypass devresin...

Page 23: ...uzun suyu aşağıdaki değerleri karşılamalıdır Tuz 5 6 Kg m pH Beton Havuz 7 2 7 6 Polyester 6 8 7 0 TAC 60 100 ppm TH 15 20 Fransız Stabilizör 20 30 ppm veya üreticinin önerisi Sıcaklık 10 C 2 4 Tuz Ekleme Tuz ekleme işlemi sırasında tuzun hepsi çözünene kadar sistem tamamen kapatılmalıdır Tuz tamamen çözünmeden sistemin çalıştırılması durumunda hücre geri döndürülemez hasar alabilir Bu nedenle olu...

Page 24: ...österilir 2 Cihaz ON OFF kapatıp açma ayar menüsüne giriş cihaz kapalı OFF konumdayken 3sn basılı tutulur ve ayar menüsünde sayfalardan ve parametrelerden çıkış fonksiyonlarını gerçekleştirir 3 Ayar menüsündeki sayfalarda ve parametrelerde seçim yapma ayarlanan parametreleri onaylayıp kaydetme fonksiyonlarını gerçekleştirir 4 Ayar menüsünde bir üst sayfaya veya parametreye geçiş ve parametre değer...

Page 25: ...se Ayarlar menüsü üzerinden ORP AYARLAR ORP MOD parametresi üzerinden değiştirilebilmektedir ORP mod AUTO konumdadır ORP sensöründe okunan değer ve SET edilen değer doğrultusunda Cl üretimi yapılır İstenen değer bulunduğunda otomatik olarak Cl üretimi durur Değiştirmek istenir ise Ayarlar menüsü üzerinden ORP AYARLAR ORP MOD parametresi üzerinden değiştirilebilmektedir 6 Ölçülen anlık pH değerinin...

Page 26: ...anır Kireç tabakası yalıtkan özellikte olduğundan elektrotlar arası elektrik akışını zorlaştırır Bunun sonucunda klor üretim verimi düşer Elektrotlarda oluşan bu kirecin belli aralıklarla temizlenmesi gerekmektedir Bu temizleme işlemini cihaz polarizasyonu değiştirerek otomatik olarak yapabilme özelliğine sahiptir Polarite peryod sayfası polarizasyon değiştirme süresinin ayarlandığı sayfadır OK bu...

Page 27: ...seçildiğinde sisteme AUTO olarak kaydedilir pH Mod AUTO Bu Mod ayarlandığında pH sensöründe okunan değer ve SET edilen değer doğrultusunda düşürücü veya yükseltici sıvının dozajlaması yapılır İstenen değer bulunduğunda otomatik olarak dozajlama durur 3 2 3b pH Set pH set değeri havuzun sahip olması istenen pH değeridir Sensörler ile okunan değer burada girilen set değeri ile karşılaştırılarak doza...

Page 28: ...rü ilk önce pH4 sıvısına daldırılır ve ekrandaki timer sıfırlanana kadar sensör sıvının içinde bırakılır Timer sıfırlandığında pH sensörünün ph7 sıvısına daldırılması gerekir ve ekrana bir ileti gelir Sensör pH4 sıvısından çıkartılıp kurulanır ve pH7 sıvısına daldırılıp OK butonuna bir kez basılır Ekrandaki timer sıfırlanana kadar sensör sıvının içinde bırakılır Timer sıfırlandığında pH sensörü ka...

Page 29: ...Mod ayarlandığında ORP sensöründe okunan değer ve SET edilen değer doğrultusunda Cl üretimi yapılır İstenen değer bulunduğunda otomatik olarak Cl üretimi durur 3 2 4b ORP Set ORP set değeri havuzun sahip olması istenen ORP RX değeridir Sensörler ile okunan değer burada girilen set değeri ile karşılaştırılarak dozajlama yapılır Dozajlanan sıvı havuzun istenen ORP RX değerinde olmasını sağlar OK but...

Page 30: ...nezyum demir ve diğer mineralleri bulundurması kaçınılmazdır Su soğuk iken askıda bulunan bu mineraller elektroliz esnasında sudan ayrışırlar bir kısmı hazne içerisindeki elektrotlara yapışırlar Belli bir süre sonra elektrotların üzeri tamamen kireç olarak tabir edilen maddeyle kaplanır Kireç tabakası yalıtkan özellikte olduğundan elektrotlar arası elektrik akışını zorlaştırırlar Bunun sonucunda k...

Page 31: ...temas etmiyor Kabloyu ve bağlantı terminallerini kontrol edin gerekiyorsa değiştirin Elektrot kablo bağlantısında problem var Elektrot kablo bağlantı terminallerini kontrol edin Yoğun kireç Hücreden kireci temizleyin ve polarite periyodunu düşürün ERR2 Kireç var Hücreden kireci temizleyin ve polarite periyodunu düşürün Su çok sert Suyu yumuşatın ERR3 Cihaz çıkışında kısa devre var Cihaz elektrot k...