GEMAŞ Genel Mühendislik Mekanik San.ve Tic.A.Ş.
İTOB Organize Sanayi Bölgesi 10001 Sok.No:28 Menderes/İZMİR TURKEY
Tel:0232 799 0 333 Fax:0232 799 0 330 www.gemas.com.tr [email protected]
10
EN GEMAS PURITRON INSTRUCTION MANUAL
V1.8
5.
It is the pH reducer/booster dosing control mode icon. Two different icons appear in this section.
pH mode:
It is in the AUTO position and dosing is done.
pH mode:
It is in the AUTO position and no dosing is made.
6.It is the icon of pool cover.
It is available in the devices with the pool cover closing control.
Thanks to the pool cover closing control on the device; It provides the ability to adjust the chlorine
production rate when the cover is closed. A switch with N.O contact (Dry Contact) is connected to the
pool cover closing control connection socket. When the pool cover is closed, the signal coming from the
switch turns the device to the cover mode and its icon appears on the screen. When the device is operating in
the covered mode, the desired production value is increased and decreased by the direction buttons.
3.2.
SETTING MENU
The setting menu is an interface with the setting pages and
parameters of the device. It allows the device to operate at an
optimum level with the changes and adjustments made. The
device is switched off to enter the setup menu. An image like the
one will be displayed on the LCD screen. The
MENU
button is
kept pressed for 3 seconds while the device is in the OFF
position. The device will automatically switch to the setting
menu.
Setting menu contents are shown in the table on the right. In
the table, the setting pages and the parameters in the pages are
indicated.
3.2.1.
POLARITY PERIOD
Although the physical properties of the water used vary depending on geographical regions, it inevitably
contains certain amounts of calcium, magnesium, iron, and other minerals. While the water is cold, these
suspended minerals dissociate from the water during electrolysis, some of them stick to the electrodes in the
chamber. After a certain period, the electrodes are completely covered with the substance called lime. Since
the lime layer is insulating, it complicates the flow of electricity between the electrodes. As a result, chlorine
production efficiency decreases. This lime formed in the electrodes must be cleaned periodically.
This cleaning process; It has the feature to do it automatically by
changing the polarization. Polarity period page is the page where the
polarization change time is set. The OK button is pressed once to
enter the page, and to exit the page, the MENU button must be
pressed once. When entering the setting page, the parameter value is
changed with UP and DOWN direction buttons. When the desired
value is given, it is selected and saved with the OK button.
3.2.2.LANGUAGE
It is the page where the working language of the device is set.
There are English - TURKISH - FRENCH - BULGARIAN - GERMAN –
HUNGARIAN - SPANISH languages defined on the device. The OK
button is pressed once to enter the page, and to exit the page, the
MENU button must be pressed once. The working language is
changed with UP and DOWN direction buttons. When the desired
working language is displayed, the OK button is pressed once and the
working language is selected and saved.
Settings
1 - POLARITY PERIOD
POLARMA HOUR
2 - LANGUAGE
ENGLISH
TURKISH
FRENCH
BULGARIAN
GERMAN
HUNGARIAN
SPANISH
3 - PH SETTINGS
PH MOD
PH SET
PH TOL.
PH BUF. SEC
PH CALIBRATION
READ PH
PH LVL. SEC
4 - P.COVER PROC.
P.COVER CL
5 - PROGRAM MENU
PASSWORD