2.2.Electrode Cell Assembly
1.Electrode Cable Choke Gasket
2.Electrode Head with Union
3.Cable Connection Terminals
4.Electrode
5.Silicone Gasket Between Electrode and Chamber
6.Electrode Chamber
7.Water Inlet Connection Part
8.Water Outlet Connection Part
The electrode cell should be installed after the last element (filter, heater, etc.)
that the water enters in the direction of return to the pool.
If an automatic pH regulator is installed in the system, the acid
injection should be after the electrode cell. Otherwise, the
electrodes interact with the acid and corrode. The manufacturer
and the seller cannot be held responsible for any damages or
problems caused by this. Repair, maintenance and parts
replacement cannot be claimed under warranty.
•
Rigid PVC glue should be used for pipe mounting to the electrode barrel and it should be allowed to dry
completely before attaching the electrode.
•
Electrode; it must be seated in the chamber in the right direction. The open part of the electrode should be
towards the water inlet pipe connection. Make sure that the silicone gasket is in place and seated in a leak-
proof way.
•
Connect the electrode cable through the choke gasket and the screwed electrode head to the cable
connection terminals. Close the threaded electrode head.
•
It is recommended to install a three-valve bypass circuit whenever possible. In this way, it enables the
adjustment of the amount of water passing through the cell and the operation of the pool while it is
removed from the electrode chamber. In the pump operating at a certain power, the bypass circuit reduces
the transition speed and prevents the electrodes from being damaged by vibration.
•
The electrode cell can be used in vertical and horizontal positions, but vertical use is recommended as far
as the environment allows. The vertical position allows the tank to be emptied without spilling water. Also,
sufficient space is provided to remove the electrode head and electrode.
•
If the cell is installed at a height below the filter outlet, gases formed as a result of electrolysis may
accumulate in the chamber, which may damage the filtration elements. It can be prevented by making an
installation as seen in this picture.