Cinterion
®
ELS81-US Hardware Interface Description
3.4 Power Supply
77
els81-us_hid_v01.004
2017-09-27
Confidential / Preliminary
Page 71 of 107
I
BATT+
(i.e., sum of
BATT+
BB
and
BATT+
RF
)
Average LTE sup-
ply current
Data transfer @
maximum Pout
SLEEP
2
@ “Paging
Occasions“ = 256
USB disconnected
mA
USB suspended
mA
SLEEP
2
@ “Paging
Occasions“ = 128
USB disconnected
mA
USB suspended
mA
SLEEP
2
@ “Paging
Occasions“ = 64
USB disconnected
mA
USB suspended
mA
SLEEP
2
@ “Paging
Occasions“ = 32
USB disconnected
mA
USB suspended
mA
IDLE
3
@ DRX=6
(UART active, but no
communication)
USB disconnected
mA
USB active
mA
LTE
4
Data transfer Band 2
mA
LTE
4
Data transfer Band 4
mA
LTE
4
Data transfer Band 5
mA
LTE
4
Data transfer Band 12
mA
1. With an impedance of Z
LOAD
=50
Ω
at the antenna connector.Measured at 25°C at 3.8V - except for Power
Down ratings that were measured at 3.0V.
2. Measurements start 6 minutes after switching ON the module,
Averaging times:
SLEEP mode - 3 minutes, transfer modes - 1.5 minutes
Communication tester settings: no neighbour cells, no cell reselection etc., RMC (reference measurement
channel). Note that SLEEP mode is enabled via AT command AT^SPOW=2, 1000, 3
3. The power save mode is disabled via AT command AT^SCFG=”MEopMode/PwrSave”, “disabled”.
4. Communication tester settings:
Channel Bandwidth: 5MHz
Number of Resource Blocks: 25 (DL), 1 (UL)
Modulation: QPSK
Table 13:
Current consumption ratings (typical ratings to be confirmed)
Description
Conditions
Typical rating Unit