The following figure shows the startup behavior of the asynchronous serial interface ASC0.
For pull-up and pull-down values see
Figure 7:
ASC0 startup behavior
Notes:
During startup the DTR0 signal is driven active low for 500µs. It is recommended to provide a
470
Ω
serial resistor for the DTR0 line to prevent shorts (high current flow).
No data must be sent over the ASC0 interface before the interface is active and ready to re-
ceive data (see
An external pull down to ground on the DCD0 line during the startup phase activates a special
mode for ELS81-US. In this special mode the AT command interface is not available and the
module may therefore no longer behave as expected.
TXD0
RXD0
RTS0
CTS0
DTR0/GPIO1
DSR0/GPIO3
DCD0/GPIO2
RING0/GPIO24
ON
EMERG_RST
PU
PD
PD
PD
PD
PU
PD
PU
Power supply active
Start up
Firmware
initialization
Command interface
initialization
Interface
active
Reset
state
V180
VCORE
PD
PU
PU
PU
PD
PD
PD