Rev. 00 01/22
26
•
Maintenance / Repairs
PH300
Pressurized pneumatics system
The pressurized pneumatics system may trigger dangerous situations.
1.
Disconnect the compressed air supply before working on the
pneumatics system.
2.
Depressurize the pneumatics system.
3.
Secure the compressed air supply against reactivation.
Cleaning
CAUTION
Large dust formation possible!
If no dust mask or one of an insufficient filter class is worn when
cleaning the product, then the dust that is stirred up from the
coating powder can cause respiratory problems.
► The ventilation system must be turned on for all cleaning work.
► A dust mask corresponding to filter class FFP2 or N95 at
minimum must be worn during any cleaning work.
CAUTION
Large dust formation possible!
If no safety glasses are worn when cleaning the product, then the
dust that is stirred up from the coating powder can cause eye
irritations.
► Safety glasses must be worn during any cleaning work.
Cleaning the interior of the powder hopper
Apart from these instructions, please also observe the generally
valid product specific hygiene information from the manufacturer.
1.
Open the cover
2.
Remove powder residues from the interior of the hopper with a
suitable industrial vacuum cleaner with a soft suction brush
3.
Use a plastic spatula to remove any deposits from the interior of the
hopper
4.
Clean the fluidizing plate
NOTICE
Fluidizing plate can be damaged during the cleaning process.
Observe the operating tools!
► Only blow off the fluidizing plate with a gentle jet of compressed
air!
► Never direct the compressed air jet directly at the fluidizing plate
and keep a sufficient distance to the plate surface!
► Do not use any liquids, do not scrape!