Rev. 03 01/21
12
Product description
OptiSpray AP01.1-E
Any other use is considered non-compliant. The manufacturer is not
responsible for any incorrect use and the risks associated with such
actions are assumed by the user alone!
For a better understanding of the interrelationships in powder coating, it is
recommended that the operating instructions for all other components be
read as well, so as to be familiar with their functions too.
Reasonably foreseeable misuse
–
Operation without the proper training
–
Use with insufficient compressed air quality
–
Input pressure too low
–
Use in connection with unauthorized coating devices or components
Technical Data
Electrical data
OptiSpray AP01.1
Nominal input voltage
24 VDC
Performance
10 VA
Protection type
IP54
Temperature range
+15 °C - +40 °C
(+59 °F - +104 °F)
Temperature class
T6
Approvals
II 3 D
Pneumatic data
OptiSpray AP01.1
Compressed air connection
Quick release connection
- 8 mm
Inlet pressure
6 bar
Max. compressed air consumption
≈ 2.0 Nm³/h
Max. water vapor content of the
compressed air
1.3 g/m³
Max. oil vapor content of the compressed
air
0.1 mg/m³
Summary of Contents for OptiSpray AP01.1-E
Page 5: ...Rev 03 01 21 OptiSpray AP01 1 E Table of contents 5 ...
Page 6: ......
Page 14: ...Rev 03 01 21 14 Product description OptiSpray AP01 1 E Rating plate fig 2 ...
Page 20: ...Rev 03 01 21 20 Product description OptiSpray AP01 1 E ...
Page 24: ...Rev 03 01 21 24 Assembly Connection OptiSpray AP01 1 E ...
Page 26: ...Rev 03 01 21 26 Start up OptiSpray AP01 1 E ...
Page 28: ...Rev 03 01 21 28 Operation OptiSpray AP01 1 E ...
Page 37: ...Rev 03 01 21 OptiSpray AP01 1 E Maintenance Repairs 37 Replacing the solenoid valves 1 2 3 ...
Page 38: ...Rev 03 01 21 38 Maintenance Repairs OptiSpray AP01 1 E 4 5 6 ...
Page 44: ...Rev 03 01 21 44 Fault clearance OptiSpray AP01 1 E ...
Page 48: ...Rev 03 01 21 48 Disposal OptiSpray AP01 1 E ...
Page 58: ......
Page 61: ......
Page 62: ...Rev 03 ...