V
02/16
18
•
Operating and display elements, operating modes
OptiMove CR08
Operating modes
The OptiMove CR08 Axis control unit provides following operating modes:
– Manual
– Keyboard
lock
The OptiMove CR08 Axis control unit enables the simply creation of 255
programs with the help of the necessary parameters.
"Manual" operating mode
The manual operation permits the selection and the start of the travel
programs by the operator on the panel. In addition, the operator has the
possibility to change the program number or directly modify the running
program.
In this operating mode, all display and operating functions are possible by
the operating panel, such as:
–
Program numbers selection
–
Input mode/display mode selection
–
Desired value setting in the input mode (only in pendulum operation)
– Start/Stop
–
Error messages acknowledgement
–
System parameter mode
Keyboard lock
In the
Keyboard lock
operating mode, the control unit operating panel is
locked. The prerequisite for it is that the
System parameter P9
must
already have been correctly set (
P9=1
, for more see "Setting the system
parameters“).
If the systems parameter
P9=1
is set, the keyboard lock function can be
activated through the remote digital input. This is displayed on the
operating panel by lighting-up of the green
Remote
LED.
Only a limited operation is possible by the operating panel, namely:
–
Start, stop, referencing axes
–
Input mode/display mode selection (desired values and actual
values visualization)
–
Error messages acknowledgement