General safety regulations
•
5
operation. Safety precautions specified by local legislation must
be observed!
8. Only original ITW-Gema spare parts should be used, because
the explosion protection will also be preserved that way. Damage
caused by other parts is not covered by guarantee.
9. If ITW-Gema powder spraying equipment is used in conjunction
with machinery from other manufacturers then their safety regu-
lations must also be taken into account.
10. Before starting work familiarize yourself with all installations and
operating elements, as well as with their functions! Familiariza-
tion during operation is too late!
11. Caution must be exercised when working with a powder/air mix-
ture! A powder/air mixture in the right concentration is flammable!
Smoking is forbidden in the entire plant area!
12. As a general rule for all powder spraying installations, persons
with pacemakers should never enter high voltage areas or areas
with electromagnetic fields. Persons with pacemakers should not
enter areas with powder spraying installations!
WARNING!
We emphasize that the customer himself is responsible for the safe
operation of equipment. ITW-Gema is in no way responsible for any
resulting damages!
Safety conscious working
Each person responsible for the assembly, start-up, operation, service
and repair of powder spraying equipment must have read and under-
stood the operating instructions and the "Safety regulations"-chapter. The
operator must ensure that the user has had the appropriate training for
powder spraying equipment and is aware of the possible sources of dan-
ger.
The control units for the spray guns must only be set up and used in zone
22. The spray guns are permitted in the zone 21 created by them.
The powder spraying equipment should only be used by trained and au-
thorized personnel. This applies to modifications to the electrical equip-
ment, which should only be carried out by a specialist.
The operating instructions and the necessary closing down procedures
must be followed before any work is carried out concerning the set-up,
start-up, operation, modification, operating conditions, mode of operation,
servicing, inspection or repairs.
The powder spray equipment can be turned off by using the main switch
or failing that, the emergency shut-down. Individual components can be
turned off during operation by using the appropriate switches.
Individual safety regulations for the operating
firm and/or operating personnel
1. Any operating method which will negatively influence the techni-
cal safety of the powder spraying equipment is to be avoided.
2. The operator should care about no non-authorized personnel
works on the powder spraying equipment (e.g. this also includes
using the equipment for non-conform work).