Rev. 00 12/21
44
•
Operation
OptiFeed 4.0 (PP07)
3.
Set the corresponding value with the
or
key.
4.
Select values according to the following table
Name / Icon
Description
Range
Default
value
Pre convey
Pre-conveying duration
(Cycles)
1 … 16
4
Post convey
After-conveying duration
(Cycles)
4 … 32
8
T-On
Duty cycle interval operation (s)
1 … 999
10
T-Int
Period duration of interval operation (s)
10 … 999
30
After-conveying length
The after-conveying length is defined by the number of programmable
cycles based on the hose length. The factory setting for the pump is 8
cycles.
8 cycles
=
for powder hoses over 2 m
16 cycles
=
for powder hoses over 25 m